Appendix B: RFPI Numbers
The RFPI is constructed from 4 different variables which make up the 10 characters
(represented by N in the format
0xNN,0xNN,0xNN,0xNN,0xNN
):
•
Access Rights Class (ARC), character 1
The network identity structure used by terminals in multi-cell. Private multi-cell
systems use the default value of 1.
•
Equipment Installer's Code (EIC), characters 2 through 5
A preset code that allows terminals to distinguish between separate DECT networks.
The minimum value is 0000; the maximum is FFFF. The default value for the EXP1240
system is 16E6.
•
Fixed Part Number (FPN), characters 6 through 8:
A geographically unique identity transmitted to DECT networks to help distinguish
between communications in different cells or chains. The minimum value is 001; the
maximum is FFF.
•
Location Area Length (LAL), characters 9 and 10:
A unique code sent to the terminal during location registration to determine the size
of the cell area. The minimum value is 00; the maximum is FF.
An example RFPI would be
ARC (char 1)
EIC (chars 2-5)
FPN (chars 6-8)
LAL (chars 9-10)
1
16E6
000
FF
The values are collapsed into a single 10-character string (116E6000FF), then the string
is separated into 5 pairs of 2 characters each:
Pair 1
Pair 2
Pair 3
Pair 4
Pair 5
11
6E
60
00
FF
Each pair is written as a 2-character HEX value (i.e.,
0x
is added to the front):
Pair 1
Pair 2
Pair 3
Pair 4
Pair 5
0x11
0x6E
0x60
0x00
0xFF
The HEX values are separated with commas, and the final result is displayed in the field
as