Manual – Starflow QSD Model 6527B and 6537A
Unidata Manual - 6527B and 6537A Starflow QSD User Manual 08 05 2023.docx
Page 111
17.15.2.3. Blocking of the Signal Paths by Objects
One strategically placed solid object,
such as a rock, stick or other
acoustically opaque material, may
block the path to either sensor,
blanketing any signals. Zero signals
will be dominant; however, those
below 20 mm/sec. are discarded. The
histogram will be distorted and have
a characteristic vertical face at 20
mm/sec.
17.16. Initialise
The
Initialise
function will conduct a memory reset on the logger unit, erasing all logged
memory. The scheme will need to be re-loaded.
17.17. Configure
The
configure
function allows direct access to the settings, which is described in
section
11.3