11.3.3. Log Intervals
The Log Interval is the time between logs. At each log, all the Instrument Channels ticked
will be recorded into the Log Buffer.
In the screenshot below, data will be logged every 5 minutes.
The maximum log interval is limited by the scan rate. The maximum log interval is 65535
times the scan rate. For example, if you set the scan rate to 1 second, the maximum
logging interval is 65535 seconds, or 18 hours 12 minutes 15 seconds. If you want a log
interval of 1 day, you will need a scan rate of at least 2 seconds.
Instrument Channel Ordering:
This defaults to Auto Order; however, you can un-tick the
checkbox and click on the Set Order button to manually set the logging order of the
channels.
Note:
You should NOT select AVE values to record for Flow Rate, Flow and Total Flow
channels, as these are already processed and cannot be averaged.