Unicum AN1244 User And Installation Manual Download Page 3

User and installation manual  

 

Réf : 004057-02

 

 

Page : 3/17 

 

Technical specifications  

 

This control box is compatible with following motors:

  

AN1244: PL3210, PL1218, DL3010 and DL1318 

AN1274: PL6010, PL3218, PL7710, DL6010, DL7710 and DL3018

 

 

 

« Pulse mode » or « Hold mode » can be selected independently on both directions (open/close). 

 

Overload detection in case of motor slow down during cover operation 

 

Security Loop (for emergency stop or alarms coming from sensors) 

 

Auxiliary Relay (for electrolyser or pump management) 

 

One-digit display for alarm notification and troubleshooting. 

 

 

FUSES CARACHTERISTICS: 

AN1244 

F1 = Fuse ATO 10A 

F2 = Fuse 5x20 3.15A Time lag 

AN1274 

F1 = Fuse ATO 15A 

F2 = Fuse 5x20 4A Time lag 

CHARACTERISTICS

AN1244

AND1274

Unit

Power feed tension

230

230

V AC

Frequency

50

50

Hz

Monophasic AC Network

L/N/PE

L/N/PE

Maximum power

210

360

VA

Zero load tension

30

30

V DC

Maximum load current

10

15

A

Dimension (HxLxP)

291x241x87 291x241x88

mm

Weight

3,5

4,7

kg

Waterproof class

IP50

IP50

Operation temperature range

0 to 50

de 0 to 50

°C

Admissible humidity

0 to 85

de 0 to 85

%

Summary of Contents for AN1244

Page 1: ...www unicum tech User and Installation Manual KEEP THIS MANUAL FOR FUTURE REFERENCE DATE VERSION MODIFICATIONS 08 2020 01 AN1244A AN1274A 05 2021 02 Modifications alarms SWx WARNING Basic safety rules...

Page 2: ...be performed by a qualified and authorized technician who has been trained to swimming pool equipment installation Before installing this product please read the whole user manual and follow all instr...

Page 3: ...from sensors Auxiliary Relay for electrolyser or pump management One digit display for alarm notification and troubleshooting FUSES CARACHTERISTICS AN1244 F1 Fuse ATO 10A F2 Fuse 5x20 3 15A Time lag A...

Page 4: ...weight of the control box Control box positioning and drilling 1 Mark on the wall the four positions corresponding to the four external holes in the corners of the box you can use the drilling positi...

Page 5: ...ection identification on the key switch Positions and rotation directions must be clearly identified on the key switch and must remain understand all along cover pool lifetime Fig 3 Example of identif...

Page 6: ...green cable can be used only for ground connection Do not forget to screw cable glands when wiring is done this guarantees correct waterproof level WARNING All electrical connections have to be made...

Page 7: ...e3 For TT operating conditions the circuit must be protected upstream by a bipolar differential circuit breaker with a sensitivity of 30 mA 6 A intensity and a type C trigger curve Use a cable H07 VV...

Page 8: ...mmon COM and contacts normally closed NC normally open NO Mode Pool cover position Etat du relais Led AUX Automatic Completely open NO Moving NC Completely closed NC Manual Depending on motor rotation...

Page 9: ...chapter 3 6 and verify that motor rotation sensor is coherent with three position key switch settings ATTENTION in FORCED mode sensor signal is not taken into account it is therefore possible to move...

Page 10: ...ntrol box has been conceived and sized in order to work continuously up to 10 minutes maximum Beyond this time try to let the board at rest for half an hour to allow components cooling down Temperatur...

Page 11: ...mit switch programming to be done Fix Unused Blinking Unused Fix Safety loop open Blinking Sensor defect Fix Sensor power supply problem Blinking Unused Fix Fuse F1 to be replaced Blinking Important A...

Page 12: ...r eyes and survey while moving the cover This mode allows a normal usage of the cover with automatic stop when limit switch is reached In this mode cover can be controlled by different devices key swi...

Page 13: ...tting is OFF micro switch 1 on SW1 set to OFF corresponding to hold mode for close device This function is inactive when control box is in MANUAL or PROGRAMMATION even if the dip switch is set to ON M...

Page 14: ...ctivated with micro switch 3 on SW1 External device has to be equipped with a contact normally closed which opens in case of abnormal condition thus blocking the motor In this case INFO ALARM display...

Page 15: ...mede force INFO ALARM display will show fix This alarm is risen just for information 4 7 Software defect INFO ALARM display will show fix In this case switch off completely the control board wait 5 se...

Page 16: ...y safe way 5 1 Maintenance Control box doesn t need special maintenance User is invited to check periodically the status of control devices especially for remotes Replace any control device when they...

Page 17: ...r normal usage corresponding to a maximum continuous usage of 10 minutes Beyond this time please wait half an hour for cooling board components Warranty is not applicable in the following cases Replac...

Reviews: