![background image](http://html2.mh-extra.com/html/unicaterm/eco-6/eco-6_user-and-maintenance-manual_3709049038.webp)
E N G
5 . ) # ! 4 % 2 -
3 8
6.0
WARNING MESSAGES
display
text
Warning message
Possible cause
Warning log
(installer/technician)
Operation to do
H1
Inactive H1
H2
Combustion
blower fan failure
detected by the fan sensor
H2
Contact your local CAT
SF
NO flame
detected by the heat sensor
measuring the exhaust fume
temperature / thermocouple
H3
Check whether the tank
there are pellets
Contact your local CAT
AF
Ignition failed
appears if no flame ignites within
15 minutes
H4
Load pellets into the cochlea
(see section 2.0 of the
manual control unit)
Clean the crucible
H5
Black out
no electric power
H5
Check that the power cord is
well plugged in and the
power switch is in the ON
position
H6
Heat sensor
(thermocouple)
disconnected or
faulty
Wear and tear of the component
H6
Contact your local CAT
H7
Flue gas
temperature
anomaly
shutdown due to excessive
smoke temperature
H7
Contact your local CAT for a
general clearing of the stove
Bat1
No clock battery
left
type CR2032
--
Replace the clock battery
6.1
RESET BUTTON
In case of overheating of the heater due to failure or
obstruction of the ventilation system, intervenes a safety
thermostat with manual reset that blocks the supply of
pellets.
Before carrying out any operation, turn off the stove and
remove the power outlet; once the stove has cooled, you
should act to solve the problem.
To reactivate the features of the stove just do the following:
-
Unscrew the protective cap;
-
Press the red reset button;
-
Screw the protective cap;
-
Do you turn the stove
Summary of Contents for ECO 6
Page 2: ...I T A 5 4 2 2...
Page 9: ...I T A 5 4 2 9 ECO 6 ECO 9...
Page 18: ...I T A 5 4 2 1 8 8 0 SCHEMA ELETTRICO...
Page 24: ...E N G 5 4 2 2 4...
Page 31: ...E N G 5 4 2 3 1 ECO 6 ECO 9...
Page 40: ...E N G 5 4 2 4 0 8 0 ELECTRIC SCHEME...
Page 46: ...D E U 5 4 2 4 6...
Page 53: ...D E U 5 4 2 5 3 ECO 6 ECO 9...