18
LINEAR LENGTH
DOUBLE Ø80
FROM
[m]
UP TO
[m]
0.5
(2)
25
(1) (5)
Connection to a combustion products evacuation
pipe outside the room; the combustion air is tak
-
en directly from the room where the appliance is
installed.
LINEAR LENGTH
DOUBLE Ø80
DOUBLE Ø60
FROM
[m]
(2)
UP TO
[m]
FROM
[m]
(2)
UP TO
[m]
0.5 - 0.5
46
(1) (3)
0.5 - 0.5
29
(1) (4)
Separate combustion air intake and combustion
products evacuation pipes.
These pipes can discharge into areas with different
pressure.
C53
B23
ATTENTION:
The flue must comply with standards
in force.
C63
Boiler intended for connection to a combustion
air intake and combustion products evacuation
system, approved and sold separately.
ATTENTION
for this type of con-
nection the room
follows the same in-
stallation rules for
boilers with natural
draught.
NOTE!
Further details in the section
‘‘Technical Information’’ on the
boiler page of the www.unicalag.it
website
Collective chimney flue
system, consisting of two
pipes, one for combustion air intake and the other
one for combustion products evacuation, coaxial
or double.
C43
Connection to a terminal for combustion air intake
and flue gas exhaust via a single or collective
chimney.
C83
Summary of Contents for KON R 18
Page 2: ...2 http www unicalag it prodotti domestico 50 condensazione gas 774 kon...
Page 10: ...10 KON R 28 R 35 KON C 28 C 35 Vista dall alto KON C 28 C 35 Vista da sotto...
Page 36: ...2 http www unicalag it prodotti domestico 50 condensazione gas 774 kon...
Page 44: ...10 KON R 28 R 35 KON C 28 C 35 View from above KON C 28 C 35 View from below...
Page 70: ......
Page 71: ......