7
Chronothermostat
The chronothermostat function is used to program
automatic cycling on and off of the heat stove
throughout the week.
To enter programming hold the button
for
about three seconds, the upper display will
show the parameter “UT01” : press the button
several times and refer to the table below to
program the stove according to your needs. To
exit programming mode at any time press the
button . The chronothermostat parameters are
as follows:
Parameter
Description
Settable values
UT01
OFF; Day 1, ...,Day7
Chrono enable and disa
-
ble. Set day of the week
UT02
from 00 to 23
Set current hour
UT03
from 00 to 60
Set current minutes
UT04
Reserved
Set technical parame
-
ters
UT05
From 00:00 to 23:50
with 10 minute steps
Adjustment of first heat
stove ignition time
UT06
From 00:00 to 23:50
with 10 minute steps
Adjustment of first heat
stove extinction time
UT07
Between on/off for
days from 1 to 7
Selection of days of the
week when first time is
activated
UT08
From 00:00 to 23:50
with 10 minute steps
Adjustment of second
heat stove ignition time
UT09
From 00:00 to 23:50
with 10 minute steps
Adjustment of second
heat stove extinction
time
UT10
Between on/off for
days from 1 to 7
Selection of days of the
week when second time
is activated
UT11
From 00:00 to 23:50
with 10 minute steps
Adjust third time of
heat stove ignition
UT12
From 00:00 to 23:50
with 10 minute steps
Adjustment of third heat
stove extinction time
UT13
Between on/off for
days from 1 to 7
Selection of days of the
week when third time is
activated
UT14
From 00:00 to 23:50
with 10 minute steps
Adjustment of fourth
heat stove ignition time
UT15
From 00:00 to 23:50
with 10 minute steps
Adjustment of fourth
heat stove extinction
time
UT16
Between on/off for
days from 1 to 7
Selection of days of the
week when fourth time is
activated
Below is the meaning of user parameters in detail:
UT01
Enable and disable/chronothermostat and set
current day.
This parameter is used to set the current day of
the week or disable programming.
Press buttons and to select the desired
value as shown in the following table:
Example:
if today is Thursday you must select “Day 4”,
whereas if you wish to ignite the heat stove
manually (without programming) you must select
“OFF”, in order to disable the chronothermostat.
Press button to move to the next parameter.
Display
Top
MEANING
Day 1
Day 2
Day 3
Day 4
Day 5
Day 6
Day 7
OFF
Monday
Tuesday
Wednesday
Thursday
Friday
Saturday
Sunday
Chronothermostat off
Parameter
Description
Settable values