Chronothermostat

The chronothermostat function is used to program 

automatic  cycling  on  and  off  of  the  heat  stove 

throughout the week.

To  enter  programming  hold  the  button 

 for 

about three seconds, the upper display will 

show  the  parameter  “UT01”  :  press  the  button 

 several times and refer to the table below to 

program  the  stove  according  to  your  needs. To 

exit  programming  mode  at  any  time  press  the 

button  . The chronothermostat parameters are 

as follows:

Parameter

Description

Settable values

UT01

OFF; Day 1, ...,Day7

Chrono enable and disa

-

ble. Set day of the week

UT02

from 00 to 23

Set current hour

UT03

from 00 to 60

Set current minutes

UT04

Reserved

Set technical parame

-

ters

UT05

From  00:00  to  23:50 

with 10 minute steps

Adjustment  of  first  heat 

stove ignition time

UT06

From  00:00  to  23:50 

with 10 minute steps

Adjustment  of  first  heat 

stove extinction time

UT07

Between  on/off  for 

days from 1 to 7

Selection of days of the 

week  when  first  time  is 

activated

UT08

From  00:00  to  23:50 

with 10 minute steps

Adjustment of second 

heat stove ignition time

UT09

From  00:00  to  23:50 

with 10 minute steps

Adjustment of second 

heat stove extinction 

time

UT10

Between  on/off  for 

days from 1 to 7

Selection of days of the 

week when second time 

is activated 

UT11

From  00:00  to  23:50 

with 10 minute steps

Adjust third time of 

heat stove ignition

UT12

From  00:00  to  23:50 

with 10 minute steps

Adjustment of third heat 

stove extinction time

UT13

Between  on/off  for 

days from 1 to 7

Selection of days of the 

week when third time is 

activated

UT14

From  00:00  to  23:50 

with 10 minute steps

Adjustment of fourth 

heat stove ignition time

UT15

From  00:00  to  23:50 

with 10 minute steps

Adjustment of fourth 

heat stove extinction 

time

UT16

Between  on/off  for 

days from 1 to 7

Selection of days of the 

week when fourth time is 

activated

Below is the meaning of user parameters in detail:

UT01 

Enable and disable/chronothermostat and set 

current day.

This parameter is used to set the current day of 

the week or disable programming. 

Press buttons   and   to select the desired 

value as shown in the following table:

Example: 

if  today  is  Thursday  you  must  select  “Day  4”, 

whereas  if  you  wish  to  ignite  the  heat  stove 

manually (without programming) you must select 

“OFF”, in order to disable the chronothermostat.

Press button   to move to the next parameter.

Display

Top

MEANING

Day 1

Day 2

Day 3

Day 4

Day 5

Day 6

Day 7

OFF

Monday

Tuesday

Wednesday

Thursday

Friday

Saturday

Sunday

Chronothermostat off

Parameter

Description

Settable values

Summary of Contents for .it AQ 15

Page 1: ...it AQ USER OPERATING INSTRUCTIONS 15...

Page 2: ...ng long by the heat stove In the event of a fire disconnect electric power use an approved fire extinguisher and if needed call the Fire Brigade Then contact the Authorised Service Centre In congratul...

Page 3: ...Air inlet pipe diameter Water inlet outlet diameter Power supply Min electric consumption Min electric consumption Tank capacity Kg 145 80 mm 50 mm 3 4 230V 50Hz 90 W 350 W in ignition phase only 17...

Page 4: ...tting the weekly or daily program ATTENTION It is recommended to use wooden pellets of maximum 6 mm diameter not moist Fig 2 6 1 2 3 4 5 SET LED SYMBOL DESCRIPTION The LED is enabled every time the pe...

Page 5: ...th a new ignition PLEASE NOTE In the event there should be repeated failed ignitions but the pellets are fed properly there might be an issue connected to breakage of the electrical igniter In this ca...

Page 6: ...after a few minutes the heat stove will resume normal operation Air temperature range 7 C 40 C ATTENTION To extinguish the heat stove do not unplug it but let the automatic extinction cycle end prolo...

Page 7: ...Between on off for days from 1 to 7 Selection of days of the week when second time is activated UT11 From 00 00 to 23 50 with 10 minute steps Adjust third time of heat stove ignition UT12 From 00 00 t...

Page 8: ...3 OFF3 Yes or No ON4 OFF4 Yes or No ON5 OFF5 Yes or No ON6 OFF6 Yes or No ON7 OFF7 Yes or No In the example below the heat stove is lit on Saturday and Sunday only Confirm and continue with button In...

Page 9: ...e automatically enters the start up stage Press keys and to adjust water temperature while use keys and to adjust operation power To switch off the heat stove press key the heat stove display will rea...

Page 10: ...stem ALAR NO ACC The heat stove is unable to ignite It is the first ignition Fill the tank with pellet Repeat ignition ALAR NO FIRE Heat stove extinction during operation Fill tank with pellets ALAR S...

Page 11: ...s Alar No Acc Press the On Off key to reset the alarm Wait for the cooling cycle to be complete clean the burn pot and proceed with a new ignition Extinction during working phase This occurs when the...

Page 12: ...ction the heat stove goes into extinction mode and the display reads Alar Dep Fail Pellet temperature safety In the extremely rare cases where an excessive temperature occurs inside the tank the manua...

Page 13: ...emove the burn pot and clean it fig 6 Fig 6 Fig 7 Scraper PERIODICALLY perform complete cleaning of the exchanger every other day When stove is cold operate the exchange duct scraper by pulling and pu...

Page 14: ...Wiring diagram 230V Mains filter...

Page 15: ...NOTES...

Page 16: ...ption or printing errors Furthermore it reserves the right to modify its products as deemed necessary or useful without affecting their essential features 46033 casteldario mantova Italy tel 39 0376 5...