Unical HP OWER 60 User'S And Installer'S Manual Download Page 15

 

 

HP_OWER

 

15

 

9.

 

TECHNICAL DATA 

TECHNICAL CHARACTERISTICS 

Unit 

Modello HP_OWER 

60 

90 

120 

150 

Electric data 

Power supply 

V/Ph/Hz 

230V/1/50Hz 

230V/1/50Hz 

230V/1/50Hz 

400V/3P+N+T/50Hz 

Total power input 

kW 

2,76 

4,55 

5,67 

7,85 

Maximum starting current 

7,8 

12,9 

16,1 

7,3 

Maximum current input 

12,1 

20,0 

24,9 

11,3 

Cooling 

Cooling capacity (1) 

kW 

2.59 - 5.37 5.84* 

4.68 - 8.79 9.42* 

5.16 - 12.23 13.15* 

6.87 - 13.95 15.60* 

Power input (1) 

kW 

1,32 

2,22 

2,94 

3,46 

E.E.R. (1) 

W/W 

4,06 

3,96 

4,16 

4,03 

Cooling capacity (2) 

kW 

1.87 - 4.13 4.65* 

3.39 - 6.49 7.90* 

3.71 - 8.20 10.40* 

4.86 - 10.51 - 12.60* 

Power input (2) 

kW 

1,33 

2,08

 

2,65

 

3,39

 

E.E.R. (2) 

W/W 

3,11 

3,12 

3,10 

3,10 

ESEER (5) 

W/W 

6,29 

6,05 

6,37 

6,28 

Heating 

Heating capacity (3) 

kW 

2.60 - 5.77 - 6.20* 

4.72 - 9.06 - 9.90* 

5.09 - 12.40 - 13.19* 

6.62 - 14.16 - 15.82* 

Power input (3) 

kW 

1.39 

2.21 

2.95 

3.45 

C.O.P. (3) 

W/W 

4.15 

4.11 

4.21 

4.11 

Heating capacity (4) 

kW 

2.46 - 5.46 - 5.78* 

4.48 - 8.80 - 9.28* 

4.81 - 11.66 - 12.43* 

6.21 - 13.75 - 14.50* 

Power input (4) 

kW 

1.63 

2.67 

3.41 

4.25 

C.O.P. (4) 

W/W 

3.34  

3.30 

3.42 

3.24 

SCOP (6) 

W/W 

3.84 

3.83 

3.84 

3.83 

Compressor 

Type 

 

Single Rotary 

DC Inverter 

Twin Rotary 

DC Inverter 

Twin Rotary 

DC inverter 

Twin Rotary 

DC inverter 

Number 

 

Power input in cooling mode (1) 

kW 

1,20 

2,04 

2,66 

3,12 

Power input in cooling mode (2) 

kW 

1,20 

1,91 

2,38 

3,06 

Power input in heating mode (3) 

kW 

1,24 

2,01 

2,72 

3,10 

Power input in heating mode (4) 

kW 

1,48 

2,47 

3,18 

3,89 

Refrigerant oil (type, quantity) 

mL 

ESTER OIL VG74, 480 

ESTER OIL VG74, 820 

FV50S, 1070 

FV50S/1400 

Fan motor 

Type 

 

Motore DC Brushless 

Motore DC Brushless 

Motore DC Brushless 

Motore DC Brushless 

Number 

 

Rated power input  

kW 

0,156 

0,188 

0,144 (×2) 

0,180 (×2) 

Rated current input 

0,68 

0,82 

0,63 (×2) 

0,79 (×2) 

Speed 

r/min 

900 

900 

800 

1000 

Max. air flow 

m

3

/s 

1,08 

1,63 

2,11 

2,59 

Refrigerant 

Type 

 

R410A 

R410A 

R410A 

R410A 

Refrigerant quantity 

kg 

1,55 

2,10 

3,65 

3,90 

Design pressure (high/low) 

MPa 

4,2/2,7 

4,2/2,7 

4,2/2,7 

4,2/2,7 

Hydraulic 
circuit 

Water flow rate (3) 

m3/h 

0,99 
0,99 

1,56 
1,56 

2,13 
2,13 

2,44 
2,44 

Available head pressure (3) 

kPa 

55,5 

31,0 

41,7 

32,1 

Rated power input of the water pump

 

(3)

 

kW 

0,063 

0,063 

0,087 

0,087 

Max power input of the water pump 

kW 

0,063 

0,063 

0,087 

0,087 

Max. current input of the water pump 

0,47 

0,47 

0,71 

0,71 

Energy Efficiency Index (EEI) 
circolatore 

 

≤ 0.23 

≤ 0.23 

≤ 0.23 

≤ 0.23 

Expansion vessel 

Hydraulic connections 

inch 

1”M 

1”M 

1”M 

1”M 

Minimum volume of water 

18 

25 

35 

45 

Noise level 

Sound pressure (7) 

dB(A) 

44÷50 

45÷53 

46÷54 

46÷54 

Dimensions 
and weight 

Dimensions (L×H×W) 

mm 

1134x719x373 

1229x861x368 

1258×1402×448 

1258×1402×448 

Max. Packing dimensions (L×H×W) 

mm 

1310x850x430 

1310x1000x430 

1430x1546x690 

1430x1546x690 

Operating weight 

kg 

75 

94 

149 

154 

Net/Gross weight 

kg 

71/79 

89/98 

142/155 

147/160 

Operating conditions: 

(1) Cooling: Outdoor air temperature 35°C; inlet/outlet water temperature 12/7°C. 
(2) Cooling : Outdoor air temperature 35°C; inlet/outlet water temperature 23/ 18°C. 
(3) Heating: Outdoor air temperature 7°C DB 6°C WB; inlet/outlet water temperature 30/35°C. 
(4) Heating: Outdoor air temperature 7°C DB 6°C WB; inlet/outlet temperature 40/45°C. 
(5) Cooling: Water temperature inlet/outlet 23/18°C. 
(6) Heating: in average climate condition; T

biv

=-7°C; water temperature inlet/outlet 30/35°C. 

(7) Sound pressure level measured at 1m from the unit, in free field, according to ISO 3746. 
(*)with Hz max function (factory installed). This function can be disabled only with optional kit Hi-T. 

N.B. The performance data are indicative and could be subject to change. In addition, the performances declared in (1), (2), (3) and (4) are to be understood 
referring to the instantaneous power according to

 

UNI EN 14511

The declared data in (6) is determinated according to UNI EN 14825. 

 

WARNING: The minimum temperature allowed for storing the unit is 5°C.

 

Summary of Contents for HP OWER 60

Page 1: ...User s and Installer s Manual 60 90 120 150...

Page 2: ...L CONNECTIONS 11 5 7 1 Wiring terminal block 11 5 7 2 Removal of protective carter for models 120 and 150 12 6 START UP 13 7 SHUTDOWNS FOR LONG PERIODS 13 8 MAINTENANCE AND PERIODICAL CONTROLS 13 9 TE...

Page 3: ...HP_OWER 3...

Page 4: ...the manufacturer as an attachment to this manual The company is available to give any detailed information about this manual and to give information regarding the use and the maintenance of its own u...

Page 5: ...86 CEE 2009 104 CE 86 188 CEE and 77 576 CEE directives Every employer shall implement such provisions and ensure that their workers to respect them We observe therefore that Do not tamper with or rep...

Page 6: ...ml m for each of the two components Respiratory protection For rescue and maintenance operation in storage tanks use self contained respirator apparatus The vapors are heavier than air and can cause s...

Page 7: ...t only by QUALIFIED PERSONNEL Before any operation on the unit make sure the power supply is disconnected WARNING MOVING PARTS RISK OF DEATH Disconnect the power supply and ensure that the fan is stop...

Page 8: ...o not exceed the maximum head loss on the plant side please see the technical data given in the table of Paragraph 12 available pressure head WARNING Connect the pipes to the attacks by using always k...

Page 9: ...WARNING The water on the charging topping up pipe must be suitably pre filtered from any impurities and suspended particles Make sure that you have installed a cartridge filter removable WARNING Befo...

Page 10: ...ALVE FO INVERTING CYCLE LR LIQUID RECEIVER EEV ELECTRONIC EXPANSION VALVE FL FILTER M AXIAL FAN SE OUTDOOR AIR TEMPERATURE P CIRCULATOR ON BOARD UNIT IN WATER INLET TEMPERATURE OUT WATER OUTLET TEMPER...

Page 11: ...witch connections altered or not properly made the guarantee will be invalidated WARNING The remote control panel is connected to the water chiller by means of no 4 wires having a 1 5 mm 2 section The...

Page 12: ...eutral output of auxiliary electric heater for plant water 230V 50Hz 5A AEH Digital output DO3 230 Vac Phase output of auxiliary electric heater for plant water 230V 50Hz 5A SAN Analogue ST9 digital D...

Page 13: ...terminate immediately WARNING The summer winter operating mode have to be selected at the beginning of the related season Frequent and sudden changes of this seasonal operating mode have to be avoided...

Page 14: ...d discharge piping of the compressor are usually high Be careful when working near condensing coils The aluminum fins are very sharp and can cause serious injuries After the maintenance operations clo...

Page 15: ...R410A R410A R410A Refrigerant quantity kg 1 55 2 10 3 65 3 90 Design pressure high low MPa 4 2 2 7 4 2 2 7 4 2 2 7 4 2 2 7 Hydraulic circuit Water flow rate 3 m3 h 0 99 0 99 1 56 1 56 2 13 2 13 2 44 2...

Page 16: ...allation and maintenance Read precautions for installation and maintenance at specific chapters on user s and installation s manual PRODUCT FICHE HP_OWER for medium temperature application Tout 55 C S...

Page 17: ...Tj bivalent temperature Pdh 4 2 kW Tj bivalent temperature COPd 2 73 Tj operation limit temperature Pdh 3 8 kW Tj operation limit temperature COPd 2 35 For air to water heat pumps Tj 15 C if TOL 20 C...

Page 18: ...Tj bivalent temperature Pdh 7 2 kW Tj bivalent temperature COPd 2 73 Tj operation limit temperature Pdh 6 9 kW Tj operation limit temperature COPd 2 48 For air to water heat pumps Tj 15 C if TOL 20 C...

Page 19: ...j bivalent temperature Pdh 9 2 kW Tj bivalent temperature COPd 2 69 Tj operation limit temperature Pdh 8 1 kW Tj operation limit temperature COPd 2 29 For air to water heat pumps Tj 15 C if TOL 20 C P...

Page 20: ...Tj bivalent temperature Pdh 10 2 kW Tj bivalent temperature COPd 2 58 Tj operation limit temperature Pdh 9 4 kW Tj operation limit temperature COPd 2 21 For air to water heat pumps Tj 15 C if TOL 20...

Page 21: ...Pd 3 50 Tj bivalent temperature Pdh 4 0 kW Tj bivalent temperature COPd 2 21 Tj operation limit temperature Pdh 3 6 kW Tj operation limit temperature COPd 2 00 For air to water heat pumps Tj 15 C if T...

Page 22: ...Pd 3 26 Tj bivalent temperature Pdh 7 1 kW Tj bivalent temperature COPd 2 10 Tj operation limit temperature Pdh 6 8 kW Tj operation limit temperature COPd 1 99 For air to water heat pumps Tj 15 C if T...

Page 23: ...OPd 3 56 Tj bivalent temperature Pdh 8 3 kW Tj bivalent temperature COPd 1 93 Tj operation limit temperature Pdh 7 4 kW Tj operation limit temperature COPd 1 69 For air to water heat pumps Tj 15 C if...

Page 24: ...OPd 3 37 Tj bivalent temperature Pdh 9 3 kW Tj bivalent temperature COPd 1 78 Tj operation limit temperature Pdh 8 5 kW Tj operation limit temperature COPd 1 55 For air to water heat pumps Tj 15 C if...

Page 25: ...cessary to refer always to the technical data label stuck on right side panel of the unit 12 HEAT PUMPS AVAILABLE HEAD PRESSURE Below the characteristic curves corresponding to Head pressure Water flo...

Page 26: ...HP OWER 26 13 WATER PUMP CURVES 13 1 MODELS HP_OWER 60 90 13 2 MODELS HP_OWER 120 150...

Page 27: ...lure in the case of insufficient water flow but it does not ensure the minimum flow rate required in order the unit can work properly Models HP_OWER 60 90 120 150 Cooling capacity for reference kW 5 3...

Page 28: ...WFCF Water flow rate correction factor PDCF Pressure drops correction factor The water flow rate and pressure drop correction factors are to be applied directly to the values given for operation with...

Page 29: ...HP_OWER 29 16 DIMENSIONS 16 1 MODELS HP_OWER 60 IN OUT 1 M 16 2 MODELS HP_OWER 90 IN OUT 1 M...

Page 30: ...HP OWER 30 16 3 MODELS HP_OWER 120 150 IN OUT 1 M...

Page 31: ...HP_OWER 31 17 WIRING DIAGRAMS 17 1 MODELS HP_OWER 60 90 Temp Sensor Heat Sink...

Page 32: ...HP OWER 32 17 2 MODEL HP_OWER 120 Temp Sensor Heat Sink...

Page 33: ...HP_OWER 33 17 3 MODEL HP_OWER 150 Temp Sensor Heat Sink CN604 CN607 DC DC1 DC2 DC DC1 DC2 20A 5mH Reactor...

Page 34: ...perature sensors for the environment thermohygrometer analysis and manage the double set point for the radiant floor panel that use a dehumidification system The intuitive interface simplifies the use...

Page 35: ......

Page 36: ...s It also reserves the right to modify its products as deemed necessary or useful without jeopardising their essential features 46033 casteldario mantova italia tel 39 0376 57001 fax 39 0376 660556 in...

Reviews: