Installation instructions
29
System with AIREX boiler and DOMESTIC HOT WATER immersion and coil STORAGE TANK with SOLAR
PANELS.
Production of water for central heating system with temperature control by means of manual mixer valve (or electric
managed by supplementary heating controller).
fig. 26
When a “COMBI” type heater is installed which is mainly an
storage tank, aside from the probes
S4
and
S5
, probes
S2
and
S3
must be enabled as well.
For the storage tank pump (
Pb
) to work, the boiler water
temperature detected by the probe
S4
must be greater than the
minimum temperature set on
PARAMETER 1
.
Furthermore, the storage tank is loaded if the boiler temperature
(probe
S4
) is higher than the temperature detected on the lower
part of the storage tank (probe
S2
) plus
PARAMETER 6
(storage
tank loading thermal delta).
When the temperature of the storage tank drops below the mi-
nimum value set on
PARAMETER 3
, the program automatically
activates the domestic hot water priority.
With this type of configuration, operation of the system pump is
no longer linked to boiler water temperature but to the minimum
storage tank temperature measured by probe
S3
.
Therefore if the combi storage tank is at a higher temperature
than the minimum set temperature (PARAMETER 3), the system
pump will be activated on demand by the room thermostat even
if the boiler is cold.
As for operation of the boiler recirculation pump and of the solar
panel loading pump, it is the same as described on page 26.
This type of system also requires installation of an anti-
condensation recirculation pump.
CALDAIA A LEGNA
Pr
VE
S4
S5
IR
VM
Pi
TAS
SONDA
FUMI
S1
Ps
VE1
CS
Pb
SCAMBIATORE AD
ACCUMULO
(TANK in TANK)
S3
S2
KEY:
Pr
VM
Pi
Pb
Ps
VE
VE1
IR
TAS
CS
S1
S2
S3
S4
S5
TKS
TA
FLUE GAS PROBE
recirculation pump (if not installed, the warranty is null and void)
manual zone mixer valve (or electric, managed by supplementary heating controller)
heating system pump
storage tank loading pump
solar heat exchanger pump
open expansion vessel
closed expansion vessel
heating system distribution (loading)
thermal discharge valve probe
solar heat exchanger
solar heat exchanger probe
storage tank bottom probe
storage tank top probe
flow temperature probe
return temperature probe
door opening microswitch
room thermostat or chronothermostat
flue gas temperature probe
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
WOOD BOILER
STORAGE TANK
HEAT EXCHANGER
(TANK in TANK)
FLUE GAS
PROBE