TM 4474 

 

 

Malfunction Possible 

causes 

Remedy 

Valve does not close 

Connected voltage too high 

Check whether there is residual voltage, 
see section 4.1 

Flange fracture (valve/ 
pipework) 

Screws not tightened uniformly, mating 
flanges not aligned 

Align pipework. 
Install new valve 

 

NOTICE! 

Observe section 10.0 before all installation and repair work! 

 

Observe section 6.4 when putting the valve back into operation! 
 
 

8.0  Dismantling of the Valve

 

In addition to the general installation guidelines and the operation safety order, the following points 
must also be observed: 
 
 

DANGER!

 

 

Depressurised pipework system 

 Cooled 

medium 

 Emptied 

installation 

 

Vent pipework systems containing corrosive, inflammable, aggressive or toxic 
media 

 

Have dismantling work carried out only by qualified staff (see point 2.3) 

 

8.1 

Replacement of wear parts 

Shut down the valve as described in section 6.2. 
 
 

 

Fig. 1   100-EVF….  G1/2, G3/4 

 

 

Fig. 5   100-EVF..N..  DN25 

 

 

Fig. 6    40-EVF..NH... (DN15, DN25) 

 
De-installation of the limit switch mounting 

Switch limit switch (803) to zero-potential. Open limit switch housing (120). Loosen hexagon nut 
(901/2) and screw it off and remove it together with switch actuator (513) from the limit switch spindle 
(243). Loosen hexagon nut (901/3) and remove it. Take off the limit switch housing (120) with terminal 
box (716) from the limit switch connection piece (246). Remove connecting piece limit switch (246) 
from solenoid housing (800). 
 

 

 

Replace the solenoid valve 

 
Switch off and dismantle the solenoid drive as described in the operating manual of the solenoid drive. 
 

DANGER! 
After continuous operation, the solenoid drive may be hot! Danger of burns! 

 
 
During the visual inspection, pay attention to the following points: 
 

1.  Damage to the valve seat (100). 
2.  Damage to the valve disc sealing (400) 
3.  Wear of the guide rings (206) 

 

In case of damage to the valve seat, replace the whole magnetic valve. 
If the sealing element becomes damaged the spare parts kit should be used. 
 

Loosen the setscrew (941). Loosen the upper part of housing (106) by turning to 
the right and screwing it off. 
 

 

 

 

Summary of Contents for 10 EV Series

Page 1: ...afety information for the use in explosion prone areas guideline 94 9 EC 3 0 Handling 3 1 Transport 3 2 Storage 3 3 Handling before mounting 4 0 Product Description 4 1 Function 4 2 Technical data 4 3...

Page 2: ...ement The use of these operating instructions suppose the qualification of the user according to paragraph 2 3 qualified staff The operating staff must be trained in accordance with the operating inst...

Page 3: ...2 20 7N 3 4 25 10N 1 32 12N 1 1 4 40 15N 1 1 2 50 20N 2 Test Pressure PT 5 EVF N 92 93 40 S8 99 X X X O O O PT 16 10 EVF N 92 93 40 S8 99 X X X O O PT 25 25 EVF N 92 93 40 S8 99 X X X O O PT 40 40 EV...

Page 4: ...hot must be removed in the way that there is no danger for persons or environment Laws and regulations must be observed 2 3 Qualified staff These are persons who are familiar with erection assembly s...

Page 5: ...ps must be mounted at both valve flanges The goods to be transported must be carefully treated During transport the valve must be protected against strokes impacts or vibration The coat of lacquer may...

Page 6: ...1 019A2 020A2 For liquefied gas in its liquid Connection G ANSI 1 2 5 3 4 7 1 10 1 1 4 12 1 1 2 15 2 20 100 EVF 019A5 019A5 Flange DN Flange ANSI 15 5N 1 2 20 7N 3 4 25 10N 1 32 12N 1 1 4 40 15N 1 1 2...

Page 7: ...lement a safety precaution e g blanking disc blind flange etc in accordance with the code of practice of the German Technical and Scientific Association for Gas and Water DVGW is recommended during al...

Page 8: ...peration When putting a valve back into operation ensure that all the necessary steps described in section 5 2 Installation and section 6 1 Commissioning are repeated 7 0 Troubleshooting 7 1 Detection...

Page 9: ...arts Shut down the valve as described in section 6 2 Fig 1 100 EVF G1 2 G3 4 Fig 5 100 EVF N DN25 Fig 6 40 EVF NH DN15 DN25 De installation of the limit switch mounting Switch limit switch 803 to zero...

Page 10: ...950 falls out Remove the complete valve disk 200 1 Fig 3 5 10 25 40 EVF N sealing of expansion bellows Fig 4 5 10 25 40 EVF N sealing of expansion bellows Drive spring dowel sleeve 943 out of torsion...

Page 11: ...cope of the warranty will not be accepted The customer shall have no right to the supply of a replacement valve Maintenance work installation of parts from other manufacturers any modifications to the...

Page 12: ...practical operation there is no effective source of ignition even in case of an error case to be assumed This also applies to spring loaded components in gas filled rooms In case of electric drives se...

Page 13: ...ting manual translation EV EVF _______________________________________________________________________________________________________ 220 100 091 05 Page 13 21 Version 06 2017 TM 4474 Fig 2 5 10 25 4...

Page 14: ...ing manual translation EV EVF _______________________________________________________________________________________________________ 220 100 091 05 Page 14 21 Version 06 2017 TM 4474 Fig 3 5 10 25 40...

Page 15: ...translation EV EVF _______________________________________________________________________________________________________ 220 100 091 05 Page 15 21 Version 06 2017 TM 4474 Fig 4 5 10 25 40 EVF N meta...

Page 16: ..._______________ 220 100 091 05 Page 16 21 Version 06 2017 TM 4474 Fig 5 100 EVF N DN25 100 504 504 110 1 403 2 403 2 948 948 948 948 948 900 1 900 1 108 1 110 2 108 2 900 2 900 2 901 1 908 207 206 503...

Page 17: ...ng manual translation EV EVF _______________________________________________________________________________________________________ 220 100 091 05 Page 17 21 Version 06 2017 TM 4474 Fig 6 40 EVF NH D...

Page 18: ...25 Fig 6 40 EVF NH DN15 DN25 11 3 List of parts Pos Item St ck Qty Benennung Description 097 1 Endschalteranbau Limit switch mounting 100 1 Ventilgeh use Valve chamber 106 1 Geh useoberteil Upper part...

Page 19: ...ring 405 1 Abstreifring Scraper ring 406 2 Packung Packing 407 1 Staubschutzmembrane Dust guard membrane 503 1 3 4 Druckfeder Pressure spring 504 1 Faltenbalg Expansion bellows 507 1 Faltenbalgst ck...

Page 20: ...478 478 488 B 565 565 578 628 628 638 C 153 153 153 194 194 194 10 EV N 92 93 B 447 447 470 478 478 B 578 578 620 628 628 C 153 153 194 194 194 25 EV N 92 93 B 447 447 470 478 478 B 578 578 620 628 6...

Page 21: ...nting manual translation EV EVF _______________________________________________________________________________________________________ 220 100 091 05 Page 21 21 Version 06 2017 TM 4474 12 0 Declarati...

Reviews: