TM 4474 

 

 

205 1 

Ventilspindel 

Valve 

spindle 

206 2 

Führungsring 

Guide 

ring 

207 1 

Magnetkern 

Solenoid 

core 

209 1 

Abwurfbolzen 

Discharge 

bolt 

210 1/3/4 

Federbolzen 

Spring 

bolt 

212 1 

Spindelführung 

Spindle 

guide 

214 1 

Ventilstift 

Valve 

pin 

218 1 

Zweiteiliger 

Ring 

Two-piece 

ring 

219/x 1 

Spindelmutter 

Spindle 

nut 

227 1 

Verdrehschutz 

Torsion 

protection 

243 

Endschalterspindel 

Limit switch spindle 

246 

Verbindungsstück Endschalter 

Conncetion piece limit switch 

249 

Endschalter Konsolenhalter 

Limit switch console owner 

400 1 

Ventiltellerdichtung 

Valve 

disc 

sealing 

402/1 1 

Flachdichtung 

Gasket 

402/2 1 

Flachdichtung 

Gasket 

402/3 1 

Flachdichtung 

Gasket 

403/1 1 

O-Ring 

O-ring 

403/2 1 

O-Ring 

O-ring 

403/3 1 

O-Ring 

O-ring 

404/1 2 

Lippenring 

Lip-ring 

404/2 1 

Lippenring 

Lip-ring 

405 1 

Abstreifring 

Scraper 

ring 

406 2 

Packung 

Packing 

407 1 

Staubschutzmembrane 

Dust guard membrane 

503 1/3/4 

Druckfeder 

Pressure 

spring 

504 1 

Faltenbalg 

Expansion 

bellows 

507 

Faltenbalgstück 

Expansion bellows piece 

509 1 

Distanzring 

Distance 

ring 

512 

1/2 

Endschalterkonsole 

Limit switch console 

513 1/2 

Endschalterbetätigung Switch 

actuator 

716 1 

Klemmkasten 

Terminal 

box 

800 1 

Magnet-Antrieb 

Solenoid 

drive 

803 1/2 

Endschalter 

Limit 

switch 

900/x 12/20 

Sechskantschraube 

Hex. 

head 

screw 

901/1 1/2/4 

Sechskantmutter 

Hex. 

nut 

901/2 1 

Sechskantmutter 

Hex. 

nut 

901/3 1 

Sechskantmutter 

Hex. 

nut 

902/1 1 

Bolzen 

Bolt 

902/2 1 

Bolzen 

Bolt 

905/1 4 

Federring 

Lock 

washer 

905/2 2/4 

Federring 

Lock 

washer 

908 1 

Sicherungsblech 

Safety 

plate 

910/1 4 

Zylinderschraube 

Cylinder 

screw 

910/2 1/2 

Zylinderschraube 

Cylinder 

screw 

910/3 2/4 

Zylinderschraube 

Cylinder 

screw 

912 1 

Splint 

Split-pin 

941 1 

Gewindestift 

Setscrew 

943 

Spannstift 

Spring dowel sleeve 

948 12/20 

Nordlockscheibe 

Nordlock 

washer 

949 1 

SL-Sicherung 

SL-retainer 

950 1 

Kugel 

Ball 

966 1 

DU-Buchse 

DU-liner 

 
Wearing parts 

Version Fig. 

Type 

Spare 

parts 

Threaded 
version 

Fig.1 

100-EVF…(G1/2, G3/4) 

Solenoid drive (800) 

Summary of Contents for 10 EV Series

Page 1: ...afety information for the use in explosion prone areas guideline 94 9 EC 3 0 Handling 3 1 Transport 3 2 Storage 3 3 Handling before mounting 4 0 Product Description 4 1 Function 4 2 Technical data 4 3...

Page 2: ...ement The use of these operating instructions suppose the qualification of the user according to paragraph 2 3 qualified staff The operating staff must be trained in accordance with the operating inst...

Page 3: ...2 20 7N 3 4 25 10N 1 32 12N 1 1 4 40 15N 1 1 2 50 20N 2 Test Pressure PT 5 EVF N 92 93 40 S8 99 X X X O O O PT 16 10 EVF N 92 93 40 S8 99 X X X O O PT 25 25 EVF N 92 93 40 S8 99 X X X O O PT 40 40 EV...

Page 4: ...hot must be removed in the way that there is no danger for persons or environment Laws and regulations must be observed 2 3 Qualified staff These are persons who are familiar with erection assembly s...

Page 5: ...ps must be mounted at both valve flanges The goods to be transported must be carefully treated During transport the valve must be protected against strokes impacts or vibration The coat of lacquer may...

Page 6: ...1 019A2 020A2 For liquefied gas in its liquid Connection G ANSI 1 2 5 3 4 7 1 10 1 1 4 12 1 1 2 15 2 20 100 EVF 019A5 019A5 Flange DN Flange ANSI 15 5N 1 2 20 7N 3 4 25 10N 1 32 12N 1 1 4 40 15N 1 1 2...

Page 7: ...lement a safety precaution e g blanking disc blind flange etc in accordance with the code of practice of the German Technical and Scientific Association for Gas and Water DVGW is recommended during al...

Page 8: ...peration When putting a valve back into operation ensure that all the necessary steps described in section 5 2 Installation and section 6 1 Commissioning are repeated 7 0 Troubleshooting 7 1 Detection...

Page 9: ...arts Shut down the valve as described in section 6 2 Fig 1 100 EVF G1 2 G3 4 Fig 5 100 EVF N DN25 Fig 6 40 EVF NH DN15 DN25 De installation of the limit switch mounting Switch limit switch 803 to zero...

Page 10: ...950 falls out Remove the complete valve disk 200 1 Fig 3 5 10 25 40 EVF N sealing of expansion bellows Fig 4 5 10 25 40 EVF N sealing of expansion bellows Drive spring dowel sleeve 943 out of torsion...

Page 11: ...cope of the warranty will not be accepted The customer shall have no right to the supply of a replacement valve Maintenance work installation of parts from other manufacturers any modifications to the...

Page 12: ...practical operation there is no effective source of ignition even in case of an error case to be assumed This also applies to spring loaded components in gas filled rooms In case of electric drives se...

Page 13: ...ting manual translation EV EVF _______________________________________________________________________________________________________ 220 100 091 05 Page 13 21 Version 06 2017 TM 4474 Fig 2 5 10 25 4...

Page 14: ...ing manual translation EV EVF _______________________________________________________________________________________________________ 220 100 091 05 Page 14 21 Version 06 2017 TM 4474 Fig 3 5 10 25 40...

Page 15: ...translation EV EVF _______________________________________________________________________________________________________ 220 100 091 05 Page 15 21 Version 06 2017 TM 4474 Fig 4 5 10 25 40 EVF N meta...

Page 16: ..._______________ 220 100 091 05 Page 16 21 Version 06 2017 TM 4474 Fig 5 100 EVF N DN25 100 504 504 110 1 403 2 403 2 948 948 948 948 948 900 1 900 1 108 1 110 2 108 2 900 2 900 2 901 1 908 207 206 503...

Page 17: ...ng manual translation EV EVF _______________________________________________________________________________________________________ 220 100 091 05 Page 17 21 Version 06 2017 TM 4474 Fig 6 40 EVF NH D...

Page 18: ...25 Fig 6 40 EVF NH DN15 DN25 11 3 List of parts Pos Item St ck Qty Benennung Description 097 1 Endschalteranbau Limit switch mounting 100 1 Ventilgeh use Valve chamber 106 1 Geh useoberteil Upper part...

Page 19: ...ring 405 1 Abstreifring Scraper ring 406 2 Packung Packing 407 1 Staubschutzmembrane Dust guard membrane 503 1 3 4 Druckfeder Pressure spring 504 1 Faltenbalg Expansion bellows 507 1 Faltenbalgst ck...

Page 20: ...478 478 488 B 565 565 578 628 628 638 C 153 153 153 194 194 194 10 EV N 92 93 B 447 447 470 478 478 B 578 578 620 628 628 C 153 153 194 194 194 25 EV N 92 93 B 447 447 470 478 478 B 578 578 620 628 6...

Page 21: ...nting manual translation EV EVF _______________________________________________________________________________________________________ 220 100 091 05 Page 21 21 Version 06 2017 TM 4474 12 0 Declarati...