UT8805E Benchtop Digital Multimeter
36
2.8.1 Statistics Operation
Statistics operation can be applied to measure the minimum, maximum, average, standard deviation of
reading during the measurements of DC/AC voltage, DC/AC current, resistance, frequency, cycle,
capacitance and temperature.
Press
→ [Stat] → [On] to enter the interface of Figure 2-42.
Figure 2-42 Interface of statistics operation
Menu of statistics operation
Function menu
Options
Description
Stat
On/Off
Display or hide the statistics operating interface
Min
The minimum reading during measurements
Average
The average of readings during measurements
Max
The maximum reading during measurements
Span
The span of readings during measurements
Std Dev
The standard deviation of readings during measurements
Samples
The number of samples during measurements
Clear
Clear current data and restart the statistic
Done
Save current settings and return to previous menu
Statistics operating method:
In statistics operation, the beginning reading of multimeter is displayed as maximum/minimum, and then
the minimum/maximum value of current readings will be displayed. The minimum, maximum, average
and reading numbers are saved in volatile memory and will be auto deleted after power off.