![UNI-T UT61B Operating Manual Download Page 5](http://html1.mh-extra.com/html/uni-t/ut61b/ut61b_operating-manual_838961005.webp)
Model:
UT61B
MANUAL
D
IODE
& C
ONTINUITY
TEST
Range
Resolution
Remark
0.001V
Open circuit voltage around 2.8V
0.1
Overload protection: 1000VDC
750VAC
Broken circuit is around > 35W, the buzzer does not beep. Good circuit resistance value is < 10
,
the buzzer beeps continuously.
F
REQUENCY
Range
Resolution
Accuracy
10Hz
0.01Hz
+/-(0.1%+4)
100Hz
0.1Hz
1kHz
0.001kHz
10KHz
0.01kHz
100KHz
0.1kHz
1MHz
0.001MHz
10MHz
0.01MHz
4
C
APACITANCE
Range
Resolution
Accuracy
40nF
0.01nF
+/-(3%+5)
400nF
0.1nF
4µF
0.001µF
40µF
0.01µF
400µF
0.1µF
+/-(4%+5)
4000µF
1µF
unspecifi ed
There is around 10nF residual reading when the circuit is open