![UNI-T UT61B Operating Manual Download Page 3](http://html1.mh-extra.com/html/uni-t/ut61b/ut61b_operating-manual_838961003.webp)
Model:
UT61B
MANUAL
2
DC V
OLTAGE
Range
Resolution
Accuracy
40mV
0,01mV
+/-(0.8%+3)
400mV
0.1mV
4V
0.001V
+/-(0.5%+1)
40V
0.01V
400V
0.1V
1000V
1V
+/-(1.0%+3)
AC V
OLTAGE
Range
Resolution
Accuracy
40mV
0.01mV
+/-(1.2%+5)
400mV
0.1mV
+/-(1.0%+3)
4V
0.001V
40V
0.01V
400V
0.1V
750V
1V
+/-(1.2%+5)
T
ABLES
Accuracy: +/-(a% r b digits) - guaranteed for 1 year
Operating temperature: 23°C +/- 5%
Relative Humidity: < 75%
Input impedance (400mV): > 3000M
all other range: 10M
Maximum input voltage: 1000V DC
Input impedance (400mV): > 3000M
all other range: 10M
Maximum input voltage: 750V AC
Displays effective value of sine wave.
mv range is applicable from 5% of range to 100% of range.