background image

 

 

3.

 

Electronic Characteristics 

Test Condition: 23℃, 60%RH, cable under test get through the test center, load resistance 
1MΩ

 

Range level 

Current range 

50mA~10A Peak 

1A~100A Peak 

Attenuation accuracy 

0.1V/A

 

0.01V/A

 

Typical DC precision 

3%±50mA

 

500mA~40A Peak

4%±50mA

40A~100A Peak

±15% Maximum 

Band-width 
(-3dB) 

UT-P4100A 

DC-600kHz Refer to the typical Amplitude frequency 

characteristic (Figure 1)

 

UT-P4100B 

DC-2MHz Refer to the typical Amplitude frequency 

characteristic (Figure 2)

 

Max current VS frequency 
characteristics curve 

Figure 3 

Phase shift 

DC

65Hz

<1.5°

 

DC

65Hz

<1°

 

Typical DC linearity 

The typical DC linearity at H level(0.01V/A), Figure 4   

Rise time 

UT-P4100A 

≤583ns

 

UT-P4100B 

≤175ns 

Max operation current 

Please refer to voltage and current rating table 

Max operation voltage 

Please refer to voltage and current rating table 

Max floating voltage 

Please refer to voltage and current rating table 

Operating voltage RMS 

CATI 600V CATII 600V CATIII 300V

 

Common mode voltage RMS 

CATI 600V CATII 600V CATIII 300V

 

Typical battery type and life.   

9V alkaline layer-built battery/ 15H

 

Low power indication 

When battery voltage is lower than 6.5V, battery indicator will 

turned red and alert.

 

Overload indication 

When the current under test surpasses the range, the buzzer 

will buzz

 

 

Voltage and current rating table 

Parameter 

Max operating current (A) 

Max 

operating 

voltage (V) 

Max 

floating 

voltage(V)

H(0.01V/A) 

L(0.1V/A) 

DC 

100 

10 

600 

600 

DC+AC peak value 

100 

10 

600 

600 

Summary of Contents for UT-P4100A

Page 1: ...www uni trend com Low Frequency ACDC Current Probe UT P4100A 100A 600kHz UT P4100B 100A 2MHz...

Page 2: ...oltage range and pollution rate while the probe s test terminal is connected to the other terminals Please do not surpass the safe voltage range if the fundamental insulation of the test terminal cann...

Page 3: ...The probe s upper and lower contact surfaces is made by precise polishing process Please protect this part or the probe could be malfunction When the battery voltage is lower than 6 5V the probe will...

Page 4: ...atalog 4 1 Summary 5 2 Introduction about probes and accessories 5 3 Electronic Characteristics 7 4 Operating instruction 9 5 Mechanic Characteristics 10 6 Environment characteristics 10 7 Maintenance...

Page 5: ...value The auto zero function make it easy for the users to operate and it also has power and low voltage indicator as well as overload sound alert The probe can be powered by battery or external power...

Page 6: ...on to make accurate measurement users need to do zero degaussing before measuring to avoid the influence of environment factors like earth magnetic field and temperature shift Auto Zero Indicator when...

Page 7: ...V A Figure 4 Rise time UT P4100A 583ns UT P4100B 175ns Max operation current Please refer to voltage and current rating table Max operation voltage Please refer to voltage and current rating table Max...

Page 8: ...600 AC peak to peak value 200 20 1200 RMS CAT III 70 7 7 07 300 300 RMS CAT II 70 7 7 07 600 600 RMS CAT I 70 7 7 07 600 600 Figure 1 UT P4100A Typical Gain VS Frequency curve Figure 2 UT P4100B Typic...

Page 9: ...ope from voltage to current display If user s oscilloscope doesn t have such function user have to manually set the corresponding attenuation ratio for instance if the probe is H level 0 01V A the osc...

Page 10: ...on the current probe clamp If the direction of the current fits the tip output will be positive On the contrary the result is negative Adjust the vertical sensitivity of the oscilloscope to get a sta...

Page 11: ...ction contact with water Handle Please use clean cloth or sponge to clean the handle Please use little alcohol instead of water to erase the dirt and parch it To maintain the performance of the produc...

Page 12: ...12 9 Packing List Packaging Name Quantity Current probe 1 9V battery 1 DC12V 1 2A adaptor 1 BNC output cable 1 Tool box 1 Instruction book 1 Warranty card 1...

Reviews: