background image

 

 

 

Preface 

First of all, thank you for purchasing our products, this instruction manual is the description about 

the function, usage, operation attention points, etc. Before use, please read the instructions carefully and 

use correctly. 

 

Manual annotation will use the following symbols to distinguish.

 

 

 
 

 
 
 
 
 
 

 

 

 

 

 

 

To avoid short out and deadly accident, the circuit under test should not surpass 600VAC 

 

This probe is not designed for naked conductor. 

 

Do not touch the conductor under test and the transducer probe during measuring. 

 

When the oscilloscope is connected to other test terminal, please be careful for these points: 

 

Please use the fundamental insulation equipment with fitful voltage range and pollution rate 

while the probe’s test terminal is connected to the other terminals. 

 

Please do not surpass the safe voltage range if the fundamental insulation of the test terminal 

cannot be met. 

 

Please operate under correct guidance about electric safety.   

 

There could be deadly electric shock if the device is damp or the users’ hand is wet. 

 

该符号表示对人体和机器有危害,必须参照说明书操作。

 

In the case of wrong operation, the user risk injury. The content under this 
mark records the relevant matters needing attention to avoid such dangers.

 

The  user  may  suffer  minor  injuries  and  material  damage  with  the  wrong 
operation. To avoid such situation, the matters under this mark need attention.

This symbol means it is harmful to the machine and human body; you must 
strictly follow the instruction manual to operate. 

Note 

This symbolizes important note about how to use the machine. 

Warning 

Warning 

Attention 

Summary of Contents for UT-P4100A

Page 1: ...www uni trend com Low Frequency ACDC Current Probe UT P4100A 100A 600kHz UT P4100B 100A 2MHz...

Page 2: ...oltage range and pollution rate while the probe s test terminal is connected to the other terminals Please do not surpass the safe voltage range if the fundamental insulation of the test terminal cann...

Page 3: ...The probe s upper and lower contact surfaces is made by precise polishing process Please protect this part or the probe could be malfunction When the battery voltage is lower than 6 5V the probe will...

Page 4: ...atalog 4 1 Summary 5 2 Introduction about probes and accessories 5 3 Electronic Characteristics 7 4 Operating instruction 9 5 Mechanic Characteristics 10 6 Environment characteristics 10 7 Maintenance...

Page 5: ...value The auto zero function make it easy for the users to operate and it also has power and low voltage indicator as well as overload sound alert The probe can be powered by battery or external power...

Page 6: ...on to make accurate measurement users need to do zero degaussing before measuring to avoid the influence of environment factors like earth magnetic field and temperature shift Auto Zero Indicator when...

Page 7: ...V A Figure 4 Rise time UT P4100A 583ns UT P4100B 175ns Max operation current Please refer to voltage and current rating table Max operation voltage Please refer to voltage and current rating table Max...

Page 8: ...600 AC peak to peak value 200 20 1200 RMS CAT III 70 7 7 07 300 300 RMS CAT II 70 7 7 07 600 600 RMS CAT I 70 7 7 07 600 600 Figure 1 UT P4100A Typical Gain VS Frequency curve Figure 2 UT P4100B Typic...

Page 9: ...ope from voltage to current display If user s oscilloscope doesn t have such function user have to manually set the corresponding attenuation ratio for instance if the probe is H level 0 01V A the osc...

Page 10: ...on the current probe clamp If the direction of the current fits the tip output will be positive On the contrary the result is negative Adjust the vertical sensitivity of the oscilloscope to get a sta...

Page 11: ...ction contact with water Handle Please use clean cloth or sponge to clean the handle Please use little alcohol instead of water to erase the dirt and parch it To maintain the performance of the produc...

Page 12: ...12 9 Packing List Packaging Name Quantity Current probe 1 9V battery 1 DC12V 1 2A adaptor 1 BNC output cable 1 Tool box 1 Instruction book 1 Warranty card 1...

Reviews: