If the sealing element becomes damaged (only applies to flange version Fig.1), the spare parts kit 
should be used. 
 

Flanged version

 

 

 

Fig.1  16/25-EVS 

Loosen set screw (941) and unscrew upper part (106). Remove stud (902) together 
with safety ring (944) and place solenoid core (207) together with spring pin (210), 
valve pin (214), pressure spring (503), hex. nut (901/2) and safety plate (908) aside 
on a clean surface.  
Loosen hex. nut (901/1) together with lock washer (905). Remove spacer (110) 
form  piston guide (221). Then pull balance piston (220) together with piston guide 
(221) out of valve chamber (100). 

 

Fig.2  40-EVS 
Fig.3  40-EVS optional with limit switch mounting 

Replace the complete solenoid valve 
 

Threaded version

 

Fig.4   120-EVS, 135-EVS 

Replace the complete solenoid valve 
 

 

NOTICE! 

Before assembly, replace O-rings (403), lip-ring (404) and wiper seal (405). 
Lubricate the piston guide with Staburags N32 lubricant. 

 
Assemble the valve in the reverse order to the dismantling. 
 
 

CAUTION!

 

Install wear parts carefully and properly and do not damage them during assembly. 

 
Examine the valve for internal and external leaks in accordance with DIN 3394-1 and finally carry out a 
function test. 
 
 

9.0 Warranty

 

Scope and period of the warranty is specified in the edition of the “General Terms of Business of the 
UNI-Geräte E. Mangelmann Elektrotechnische Fabrik GmbH” valid at the time of delivery or else in the 
purchase agreement. 
 
We warranty that the valve is free from faults in line with the state of the art and for the confirmed field 
of application. 
 
No warranty claims will be accepted for damage resulting from improper use or failure to observe 
these operating and installation instructions, the statutory accident prevention regulations, the EN, DIN 
and VDE standards and other codes and regulations.  
 
Warranty claims will also not be accepted for damage occurring during operation due to operating 
conditions deviating from those specified in the data sheet or in other agreements. 
 
Justified complaints will be remedied by reworking by us or specialist companies authorised by us. 
 
Claims going beyond the scope of the warranty will not be accepted. The customer shall have no right 
to the supply of a replacement valve. 
 
Maintenance work, installation of parts from other manufacturers, any modifications to the design and 
natural wear are not covered by the warranty. 
 
Transport damage must be reported not to us but 

without delay

 to your responsible goods handling 

 

 

Summary of Contents for 40-EVS Series

Page 1: ...6 Safety information for the use in explosion prone areas guideline 94 9 EC 3 0 Handling 3 1 Transport 3 2 Storage 3 3 Handling before mounting 4 0 Product Description 4 1 Function 4 2 Technical data...

Page 2: ...rding to paragraph 2 3 qualified staff The operating staff must be trained in accordance with the operating instructions The operating manual must always be available at the location where used 1 1 Va...

Page 3: ...ignal terms DANGER CAUTION und NOTICE are used in this operating manual in case of notices concerning special dangers or for unusal information requiring a special marking DANGER means that in case of...

Page 4: ...pecified temperature class is kept in the time The valve must be connected to the ground In the case most simple this can be realized via pipe screws by means of tooth disc Otherwise the connection to...

Page 5: ...IN EN 13611 DIN 3394 1 and DIN EN 161 DIN EN 264 with solenoid drive Sectional drawing 11 1 Fig 1 4 shows the valve construction 4 1 Function By switching on the solenoid drive the solenoid core 207 i...

Page 6: ...and in observance of the warnings in this operating manual Apart from that the operation safety order and the qualified use of tools and protection equipment must be guaranteed The operating instructi...

Page 7: ...ons have to be observed e g the operation safety order 6 3 Maintenance Solenoid valves have to be checked at regular intervals for proper function and internal leak tightness The intervals for regular...

Page 8: ...close Connected voltage too high Check whether there is residual voltage see section 4 1 Flange fracture valve pipework Screws not tightened uniformly mating flanges not aligned Align pipework Instal...

Page 9: ...m during assembly Examine the valve for internal and external leaks in accordance with DIN 3394 1 and finally carry out a function test 9 0 Warranty Scope and period of the warranty is specified in th...

Page 10: ...ion as per the requirements of 98 23 EG annex III module H The oil solenoid valves correspond to the basic requirements of guidelines 97 23 EG Valves with permitted operating pressures of 0 5bar and D...

Page 11: ...________________________________________________________________________________________________________ 220 100 022 10 page 11 19 edition 10 2013 TM 3300 11 0 Sectional drawing 11 1 Fig 1 16 25 EVS 1...

Page 12: ...manual translation EVS ________________________________________________________________________________________________________ 220 100 022 10 page 12 19 edition 10 2013 TM 3300 Fig 2 40 EVS X Option...

Page 13: ...nual translation EVS ________________________________________________________________________________________________________ 220 100 022 10 page 13 19 edition 10 2013 TM 3300 Fig 3 40 EVS optional wi...

Page 14: ...nd mounting manual translation EVS ________________________________________________________________________________________________________ 220 100 022 10 page 14 19 edition 10 2013 TM 3300 Fig 4 120...

Page 15: ...ng 403 2 1 O Ring O ring 403 3 1 O Ring O ring 403 4 1 O Ring O ring 404 1 1 2 Lippenring Lip ring 404 2 1 Lippenring Lip ring 405 1 Abstreifring Wiper seal 503 3 Druckfeder Compresssion spring 513 1...

Page 16: ...8 118 127 140 165 203 216 241 292 406 Installation length A 3 152 178 203 229 267 292 317 356 445 16 EVSA B 450 B 610 C 191 D 68 25 EVSA B 450 450 460 B 610 610 620 C 191 191 191 D 68 68 75 A1 Dimensi...

Page 17: ...unting manual translation EVS ________________________________________________________________________________________________________ 220 100 022 10 page 17 19 edition 10 2013 TM 3300 12 0 Declaratio...

Page 18: ...Operating and mounting manual translation EVS ________________________________________________________________________________________________________ 220 100 022 10 page 18 19 edition 10 2013 TM 3300...

Page 19: ...Operating and mounting manual translation EVS ________________________________________________________________________________________________________ 220 100 022 10 page 19 19 edition 10 2013 TM 3300...

Reviews: