27
EN
14.3) PARAMETERS, LOGICS AND SPECIAL FUNCTIONS
The following tables describe the functions available on the control unit
14.3.1) INSTALLATION (
INST
)
MENU
FUNCTION
MIN-MAX-(Default)
MEMO
BOOM
Not usable
(3-5)
Pos
Set the closing direction of the barrier (see fig. 3)
The symbol
0---
indicates right barrier (R/RIGHT) DEFAULT
The symbol
---0
indicates left barrier (L/LEFT)
Verify the opening direction of the boom and in case reverse it. Every change of this func-
tion automatically implies the starting of a new AUTOSET procedure.
0---
= RIGHT
---0
= LEFT
( RIGHT )
Mode
Select the use mode of the barrier.
Norm
: Standard operating mode, for barriers used in a residential/industrial environment and
with normal traffic.
Parc
: Park operating mode, for barriers used in parking systems. In this mode, to promote
transit of a high number of vehicles, the control unit automatically sets a specific configuration
which includes:
1) Rapid closure enabled (SCL:ON) with time reduced from 3 to 0 seconds.
2) Automatic closure enabled (TCA:ON) which with rapid closure enabled causes, during the
opening phase, immediate closure of the barrier as soon as the PHOT input is free.
3) During the closure phase, PHOT entrance activation stops the barrier, as soon as the PHOT
input is free again, the barrier starts the closure manoeuvre.
Norm - Parc (Norm)
14.3.2) PARAMETERS (
PAR
)
MENU
FUNCTION
MIN-MAX-(Default)
MEMO
TCA
Automatic closing time. Enabled only with logic “TCA”=ON.
At the end of the set time, the control unit commands a closing manoeuvre .
1-240-(20s)
FST0
It adjusts the barrier opening speed (standard speed, before the slowing phase).
50-99-(99)
FSTc
It adjusts the barrier closure speed (standard speed, before the slowing phase).
50-99-(99)
sldo
Adjusts the slowdown speed of the barrier during the opening phase* (Fig.10) .
10-50-(10)
sldc
Adjusts the slowdown speed of the barrier during the closing phase* (Fig.11)
10-50-(10)
tsmo
Sets the starting point of the slowdown during the opening phase (Fig.10).
The value is expressed in percentage on the entire stroke.
1-99-(25)
tsmc
Sets the starting point of the slowdown during the closing phase (Fig.11).
The value is expressed in percentage on the entire stroke.
1-99-(25)
PMO
Adjusts the motor torque applied to the barrier during the opening phase (Fig.10 - FSTO).*
1-99-(10)
PMC
Adjusts the motor torque applied to the barrier during the closing phase (Fig.11 - FSTC).*
1-99-(10)
PSO
Adjusts the motor torque applied to the barrier during the slowdown in opening phase*
(Fig.10 - SLDO).
1-99-(10)
PSC
Adjusts the motor torque applied to the barrier during the slowdown in closing phase*
(Fig.11 - SLDC). .
1-99-(10)
TACC
It adjusts the time the barrier takes to go from stop status (in opening or closure) to the speed
set by the FSTC/FSTO parameters.
Value expressed in tenths of a second.
3-30 (3)
TDEC
It adjusts the time the barrier takes to go from the speed set by the FSTC/FSTO parameters (in
opening or closure) to the speed of the slowing phase SLDO/SLDC.
Value expressed in tenths of a second.
3-30 (3)
SeaU
Adjusts the intervention threshold of the anti crushing device (Encoder) during the normal speed*.
0:Off -1: minimum sensitivity - 99: maximum sensitivity
0-99-(0%)
SEAR
Adjusts the intervention threshold of the anti crushing device (Encoder) during the slowdown
speed*.
0:Off -1: minimum sensitivity - 99: maximum sensitivity
0-99-(0%)
tls
Activation time of the courtesy light contact. Value expressed in seconds. At the beginning of
each manoeuvre the contact latches for the set time.
See the description of AUX1 parameter.
1-240 (60)