2.1 Features 

  (1)    Removal of oil mist with high efficiency 

Approx.  90%  of  the  oil  mist  discharged  from  an  oil  sealed  rotary  vacuum 

pump  can  be  removed,  allowing  the  work  environment  to  be  kept  free  from 
contamination with oil mist. 

(2)

 

Employment of cartridge type filter element 

The cartridge type filter element can be easily replaced when it is clogged or 

corroded. 

(3)

 

Pump internal pressure relief valve 

If the filter element is clogged, the pressure in the pump will rise at start-up 

of the pump or during pumping operation, which can be dangerous. 

If  the  pressure  in  the  pump  rises  above  0.03  MPa  (0.3  kg/cm

2

)  (gauge 

pressure), the pressure relief valve will be activated to prevent the pump and 
oil mist trap from being damaged. 

 

2.2  Specifications 

 

Table 1    Specifications 

                                  Model 

Item 

TM201 

TM401 

Filter element 

TM201E 

TM401E 

Displacement                          m

3

/h 

*1

 

 

                                           

L/min

 

24 

400

 

48 

800

 

Connecting part dia. 

Pump side 

VF40 

*2

 

VF40 

*2

 

Exhaust side 

G1 1/2 internal thread 

*3

 

Outside 

  dimensions (mm) 

Overall height 

280 

350 

Overall width 

181 

181 

Diameter 

165 

165 

Weight    (kg) 

8.5 

10 

 
*1)      Throughput under atmospheric pressure. 
*2)      The flange is the JIS vacuum flange (JIS B 2290). 
*3)      Same as PF 1 1/2. 
 

Summary of Contents for TM201

Page 1: ...SK00 6740 DI 002 03 No 170821 INSTRUCTION MANUAL OIL MIST TRAP MODEL TM201 TM401 Components division ULVAC Inc Read this manual before operation and keep it at your hand for immediate reference...

Page 2: ...il 7 4 INSPECTION 8 4 1 Schedule Inspection 8 4 2 Replacing the Filter Element 8 4 2 1 Removing the filter element 8 4 2 2 Reassembling the filter element 10 5 PRECAUTIONS 11 5 1 Clogging of Filter El...

Page 3: ...Fig 1 Dimensional drawing TM201 3 Fig 2 Dimensional drawing TM401 4 Fig 3 Schematic diagram 5 Fig 4 TM201 TM401 mounted in position 6 Fig 5 Exploded view of filter element 9 Table 1 Specifications 2 T...

Page 4: ...oil mist trap read this manual carefully for optimum performance and operate it correctly Note that incorrect operation may cause trouble of the oil mist trap Also keep this manual in your file so th...

Page 5: ...l rise at start up of the pump or during pumping operation which can be dangerous If the pressure in the pump rises above 0 03 MPa 0 3 kg cm2 gauge pressure the pressure relief valve will be activated...

Page 6: ...3...

Page 7: ...4...

Page 8: ...h fine particles of oil blown up These fine particles of oil oil mist are trapped by the filter element when they pass through it and the condensed large oil particles gather between the oil mist trap...

Page 9: ...r local ULVAC organization or representative 3 2 Mounting on Pump Refer to Fig 4 To mount the oil mist trap on the pump proceed as follows 1 Verify that the exhaust port O ring groove and oil mist tra...

Page 10: ...than the new oil used in the pump or if the oil contains water dust or the like or if chemicals like acid is used It can be a cause of trouble of the pump CAUTIONS If you do not dispose of the trapped...

Page 11: ...place it as a rule 4 2 1 Remove the filter element 1 Stop the pump or put the pump under no load operating condition and loosen the Allen screw M8 that fixes the oil mist trap to the pump to remove th...

Page 12: ...9...

Page 13: ...ing the spacer nut 5 Mount the parts of pressure relief valve CAUTIONS Tighten the hex nut M10 until it comes into contact with the spacer nut The pressure relief valve is activated at a pressure belo...

Page 14: ...ent temperature it will be deposited on the fiber of the filter element leading to clogging When reaction products are generated 5 2 Pressure Relief Valve This device is designed to operate when the p...

Page 15: ...rent one is recommended 5 4 When using Oil Mist Trap for a Pump that exceeds Maximum Throughput Do not operate the pump continuously at a high intake pressure of 6500 Pa or more when the TM201 is used...

Page 16: ...bient temperature 10 to 40 b Suction gas Dry air or dry nitrogen 0 to 40 c Operation in conformity with instruction manuals 3 Troubles caused by the following are out of warranty a Acts of God and for...

Page 17: ...t No Description Material Q ty Remarks 1 Filter element 1 set TM201 TM201E TM401 TM401E 2 O ring G145 NBR 1 JIS B 2401 3 Seal washer M10 NBR 1 The exhaust port of the TM201 and TM401 are provided with...

Reviews: