background image

 

3

 

3.

 

Installation

 

 

Check line voltage 

Before turning on power, make sure that the operating voltage and supply 
voltage are in agreement. If incorrect power is applied, damage or fire can 
result.   

 

Turn off power 

If the AC adapter fails, immediately turn off the power. Otherwise, fire or 
electric shock can result.

 

 

Check connection 

Before turning on power, make sure that the AC adapter is correctly 
connected. Otherwise, components may be damaged. 

 

3.1.

 

Preliminary Operation 

(1)    Unpack the carton and check quantities. 
(2)

 

Make sure that the AC adapter is not damaged in transit. 

 
3.2.

 

Installation 

The withstand voltage of the supplied power cord is 125 VAC and the receptacle shape is the A type. 
So do not use it on a voltage higher than 125 VAC. If it is to be used on a voltage around 200 VAC, 
use another power cord. 
The pin assignment of the output cable is as shown on the dimensional drawing. Do not make 
mistake pin numbers. If power is supplied to an incorrect pin, the unit may be damaged. Also tighten 
the screw securely so that the power connector does not come off.   
Connect the socket plug. Always connect it to ground. 

1   

Power + 24 V (P(+)) 

 

Pin for sup24VDC power. Plug the white cable of the DC output cable  to the power 
connector of ISG1’s accessory. 

2   

Power GND (N (-)) 

 

Ground for sup24 VDC power. Plug the black cable of the DC output cable to the power 
connector of ISG1’s accessory. 

3   

Frame GND (    ) 

 

Frame ground. Plug the green  cable of the DC output cable  to the power connector of ISG1’s 
accessory. 

 

After plugging the wiring to the power connectors, firmly tighten the slotted screws on the 
connector using a slotted screwdriver. 

 

ISG1 power supply connectors 

 

9

13

15

14

12

11

10

5

8

6 7

4

3

2

1

5

8

6 7

4

3

2

1

9

13

15

14

12

11

10

P(+) N(-)

DC24V

I / O

SENSOR

3

2

1

P(+) N(-)

DC24V

Summary of Contents for SPU61A-108

Page 1: ...apter SPU61A 108 Instruction Manual Read this manual before using this instrument and keep it at hand for immediate reference Components Division ULVAC Inc 2500 Hagizono Chigasaki Kanagawa 253 8543 Ja...

Page 2: ...fety symbols are used throughout this instruction manual to call the operator s attention to safety The terminology used in safety symbols is classified below Indicate status of urgency of danger when...

Page 3: ...ntact your local ULVAC representative or ULVAC Inc Japan for repair Operating environment Do not use this instrument in a place where it may be splashed with water If it is wetted with water failure e...

Page 4: ...afety Precautions ii Contents iii 1 Specifications and Components 1 1 1 StandardSpecifications 1 1 2 StandardAccessories 1 1 3 OptionalAccessories 1 2 Dimensional Drawing 2 3 Installation 3 3 1 Prelim...

Page 5: ...torage humidity 0 95 non condensing Reliability MTBF 100 000 hours min at max load for 25degree centigrade ambient temperature Applicable standard Safety standard UL CSA C22 2 No 60950 TUV IEC60950 PS...

Page 6: ...2 2 Dimensional Drawing mm inch DC24VOutputCable WHITE V BLACK V GREEN F G 1 2m...

Page 7: ...se another power cord The pin assignment of the output cable is as shown on the dimensional drawing Do not make mistake pin numbers If power is supplied to an incorrect pin the unit may be damaged Als...

Page 8: ...e cause Corrective action Power connector is disconnected Check the power inlet connector for connection Power cord is not in continuity Check the wires of the power cord for continuity and insulation...

Page 9: ...ULVAC representatives for repair Return charge shall be paid by Buyer Disclaimer 1 Failure occurred after expiration of warranty period 2 Failure caused by force majeure such as fire storm and flood...

Reviews: