Specifications and Components 

1.1.

 

Standard Specifications 

Model 

SPU61A-108 

Input voltage 

90 to 264 VAC 

Input current 

1.45 A @ 100 VAC maximum 

Efficiency 

88% @ rated load 

Frequency 

47 to 63 Hz 

Output voltage 

24 VDC 

Output current 

2.5 A 

Power requirement 

60 W 

Output variation 

±

 3% 

Ripple and noise (Vp-p) 

240 mV 

Protection 

Overvoltage, short-circuit protection, overload protection 

Hold up time 

<10msec under the condition of typical input with full loading 

Operating temperature

 

0

70

 

Operating humidity

 

0

95%(non-condensing) 

Storage 

temperature

 

-40

85

 

Storage 

humidity

 

0

95%(non-condensing) 

Reliability 

MTBF 100,000 hours min. at max.load   

for 25degree centigrade ambient temperature. 

Applicable standard 

Safety standard: UL/CSA C22.2-No.60950/TUV/IEC60950,PSE 

FCC classB,EN 55022 & EN55024 classB 

Power cord 

for Japan

 

PSE 

Power cord 

for Korea

 

SZ04001-1006,SZ4001-1006 

Power cord 

for China

 

CH00717589-2001A,CH004442389-2000 

Power cord ( for Germany) 

N13389 

Power cord ( for USA) 

UL/CSA 

 
 
1.2.

 

Standard Accessories 

Power cord 

125 VAC, 7 A, 1.8m long,    Plug type: type A 

1 pc. 

 
 
1.3.

 

Optional Accessories 

Power cord

for Korea

 

250VAC, 7 A, 2m long        type K 

1 pc. 

Power cord

for China

 

250VAC, 10 A, 2m long      type GB 

1 pc. 

Power cord ( for Germany) 

250 VAC, 10A, 1.8m long    type CCC7 

1 pc. 

Power cord( for USA) 

125 VAC, 15A, 2m long      type A 

1 pc. 

Summary of Contents for SPU61A-108

Page 1: ...apter SPU61A 108 Instruction Manual Read this manual before using this instrument and keep it at hand for immediate reference Components Division ULVAC Inc 2500 Hagizono Chigasaki Kanagawa 253 8543 Ja...

Page 2: ...fety symbols are used throughout this instruction manual to call the operator s attention to safety The terminology used in safety symbols is classified below Indicate status of urgency of danger when...

Page 3: ...ntact your local ULVAC representative or ULVAC Inc Japan for repair Operating environment Do not use this instrument in a place where it may be splashed with water If it is wetted with water failure e...

Page 4: ...afety Precautions ii Contents iii 1 Specifications and Components 1 1 1 StandardSpecifications 1 1 2 StandardAccessories 1 1 3 OptionalAccessories 1 2 Dimensional Drawing 2 3 Installation 3 3 1 Prelim...

Page 5: ...torage humidity 0 95 non condensing Reliability MTBF 100 000 hours min at max load for 25degree centigrade ambient temperature Applicable standard Safety standard UL CSA C22 2 No 60950 TUV IEC60950 PS...

Page 6: ...2 2 Dimensional Drawing mm inch DC24VOutputCable WHITE V BLACK V GREEN F G 1 2m...

Page 7: ...se another power cord The pin assignment of the output cable is as shown on the dimensional drawing Do not make mistake pin numbers If power is supplied to an incorrect pin the unit may be damaged Als...

Page 8: ...e cause Corrective action Power connector is disconnected Check the power inlet connector for connection Power cord is not in continuity Check the wires of the power cord for continuity and insulation...

Page 9: ...ULVAC representatives for repair Return charge shall be paid by Buyer Disclaimer 1 Failure occurred after expiration of warranty period 2 Failure caused by force majeure such as fire storm and flood...

Reviews: