Connect the UP616 to a 24V DC power supply or use an appropriate LiPo battery
as an input power source. Connect the battery to be charged, then short press the
roller wheel to activate the program setting menu. The items in the menu are as
follows:
The default mode of the UP616 is series charging, therefore you must connect the
output wires to the battery pack that you wish to charge. For lithium packs, it is
highly recommended to ALWAYS connect the balance leads and utilize balance
charging. Although the UP616 will charge without the balance function, a warning
tone will sound to alert you that the balance connector is not in use.
Current
Select desired charge current (0.1-16.0A) , discharge current (0.1-3.0A)/Ext.discharge(0.1-15.0A)
Mode
Work mode: Charge / Discharge / Storage / Ext.DISC
Battery
Select battery chemistry
Back
Return to previous screen or function
TVC
Terminal voltage control
Start
Begin process
Cells
Select number of battery pack cells
10
System Settings