E-mail: [email protected]

Summary of Contents for UP616

Page 1: ...www ultrapower hk Smart Charger Instruction Manual UP616 400W ...

Page 2: ...This means energy savings through efficiency reduced heat build up and the ability to produce a small compact and conveniently mobile charging device Furthermore the UP616 firmware can be updated through a convenient micro USB port using a PC Please be sure to carefully read all INSTRUCTIONS WARNINGS and SAFETY NOTES prior to using the UP616 For more details please visit www ultrapower hk www ultrap...

Page 3: ...eters and Characteristics Default Battery Types and Settings Confirming Charge Current System Settings Working Parameters Display System Default Settings Menu External Discharge Function Warnings and Error Messages Conformity Declaration 04 06 07 08 09 10 12 13 14 15 16 Contents ...

Page 4: ...dust dirt moisture rain and high temperature Avoid leaving your charger or battery in direct sunlight or exposing them to intense vibration or shock ALWAYS make certain to observe proper input and output polarity The UP616 operates safely with input voltage between 9V 32V DC ALWAYS place the charger on a heat resistant non flammable surface when in use Keep flammable materials away from charger when...

Page 5: ...e sure that all charging parameters are correctly setup prior to charging any battery INCORRECT SETTINGS MAY CAUSE FIRE PROPERTY DAMAGE AND OR PERSONAL INJURY ALWAYS press the roller wheel to terminate charge completely when battery is fully charged and return to the standby screen on the LCD display 05 Warnings and Safety Notes ...

Page 6: ...er system settings terminate current task Short Press Enter system settings confirm current setting 06 7 6 1 2 4 IPS LCD Display Screen 2 External Discharger Port 3 Roller Wheel 4 Battery Output 5 Universal Balance Port 6 DC Power Input 7 PC Link 3 1 2 5 4 Ex t D IS C ...

Page 7: ...A Discharge Current 0 1 3 0A 0 1 15 0A External Discharge Mode Max Charge Power 400W Max Discharge Power 8W 200W External Discharge Mode Balance Current 1000mA cell Balance Cells 6S Support Battery LiFe LiIon LiPo LiHV 1 6S Types NiMH NiCd 1 16S Pb 1 12S Display Type 2 4 320x240 IPS LCD Use Temperature 0 40 Storage Temperature 20 60 70MM 90MM 2 4 320x240 IPS LCD ...

Page 8: ...ailure to do so may result in battery damage explosion or fire LiHV 3 80V 4 35V 3 90V 3 10 3 40V 3 20V supported 16 0A supported 1 6S LiFe 3 20V 3 60V 3 30V 2 60 2 90V 2 90V supported 16 0A supported 1 6S Pb 2 00V 2 40V Not supported 1 80 2 00V 2 00V Not supported 16 0A supported 1 12S NiCd NiMH 1 20V 1 40V Not supported 0 5 1 10V Not supported 16 0A supported 1 16S LiIon 3 60V 4 10V 3 70V 2 90 3 2...

Page 9: ... pack on the main label Multiply the C rating of the battery pack by the capacity to determine the safe and proper charge current For example a 1000mAh battery with a 5C rating means that the maximum charge rate should be 1000 capacity in milliamps X 5 C rating 5 000 mAh Therefore the maximum charge rate for a 1000mAh 5C lithium battery should be 5A 5 000mAh If it is not possible to determine the ...

Page 10: ... For lithium packs it is highly recommended to ALWAYS connect the balance leads and utilize balance charging Although the UP616 will charge without the balance function a warning tone will sound to alert you that the balance connector is not in use Current Select desired charge current 0 1 16 0A discharge current 0 1 3 0A Ext discharge 0 1 15 0A Mode Work mode Charge Discharge Storage Ext DISC Bat...

Page 11: ...to safely accept a fast charge rate The UP616 features the ability to monitor the internal resistance of each cell in a lithium battery pack This feature is only operational when in the balance charging mode Internal resistance can be useful to determine the overall health and performance of a lithium battery the closer the IR values are between the cells in the battery pack the better that the ba...

Page 12: ...parameters Cell voltage and IR can only be displayed during the balance charging process Cell Voltage Charge Discharge Time Charge Discharge Current Battery Percentage Working Mode Battery Cell Count Battery Capacity Battery Voltage Battery Type LiPo 6S Charge 96 25 0V 16 0A 13000mAh 1 4 2 5 3 6 4 17V 4 16V 4 17V 4 17V 4 16V 4 17V 0 50 00 Working Parameters Display 12 ...

Page 13: ... Language MAX Input Power MIN Input Voltage Capacity Cut Time Cut Backlight Volume About Factory Reset Back Adjustable from 50W 450W English Adjustable from 9V 24V Terminates charge process when reach this value Maximum capacity can be adjusted by user Terminates charge process when exceeding time set by user Returns all settings to factory default values Three options High Medium Low Four options...

Page 14: ...ed and saving time Meanwhile compared with the traditional discharger the UP616 has a balancing discharge function which can effectively avoid single cell over discharge which will be more safely and reliable External Discharge Function 14 Ext DISC LiPo 6S Ext DISC 25 0V 8 0A 1300mAh 1 4 2 5 3 6 4 17V 4 16V 4 17V 4 17V 4 16V 4 17V 0 10 00 UP616 CHARGER UP D200 EXTERNAL DISCHARGER UP D200 UP D200 B...

Page 15: ...s free from dirt or oxidation Make sure that the Max Input Voltage is set correctly in the System menu A note about Min Input Voltage This setting helps to protect excessive discharge of a source battery used as input power For example if a 6S LiPo is used as an input source the value should be set to 21V to guard against over discharging the source battery When the UP616 senses input voltage lowe...

Page 16: ...ts useful life Take your charger to your local waste collection point or recycling centre This applies to all countries of the European Union and to other European countries with a separate waste collection system For EC directive The product has been tested to meet the following technical standards Testing standards EN 55014 1 2006 A1 2009 A2 2011 EN 55014 2 2015 Result YES YES Conformity Declara...