1  ABOUT THIS MANUAL 

This manual has been prepared by Ultralife Corp for the purpose of providing a maintenance technician the 
information necessary to understand and to maintain the CH0003 Battery Charger/Conditioner.  

1.1  Symbols Used  

The symbols shown in this section appear throughout this manual, the first one shown being the NOTE 
symbol, below, which is self-explanatory. 

 
NOTE:

 

Note statements contain important information that may affect how you use 

this product. 

 

 

The other symbols represent important safety advice, and they appear 

throughout this manual and on the CH0003 in the form of WARNINGS and CAUTIONS 
against possible hazards to people or equipment, respectively. These safety WARNINGS and 
CAUTIONS must be followed at all times.  

 
WARNING:

 

Warning statements mean danger. They identify practices, procedures 

or conditions such as high voltage that could result in injury or loss of life and 
which, therefore, require extreme care before proceeding. 

 

 
CAUTION:

 

 Caution statements denote a hazard. They identify practices, 

procedures or conditions that could result in damage to or destruction of this 
product or other equipment or property. 

 

 
Ground: 
 This symbol is placed adjacent to grounding locations on the unit. 
These areas are designed to be connected to an earth ground either through a 
power cable or grounding cable to prevent injury to the user. 

 

 

Ground:  This symbol is placed adjacent to grounding locations on the unit. These 
areas are designed to be connected to an earth ground either through a power 
cable or grounding cable to prevent injury to the user. 

 

 
Direct Current: 
 This symbol is placed adjacent to the Direct Current (DC) input 
location on the unit. This connector is designed to be connected to only a DC 
source. 

 

 

DC Polarity:  These two symbols are placed next to their corresponding DC input 
connectors to identify positive and negative to the user. The “+” symbol indicates 
the red positive terminal, and the “-“symbol indicates the black negative terminal. 

 

Ultralife Corp assumes no liability for the customer’s failure to comply with these WARNINGS 
and CAUTIONS. 

Summary of Contents for CH0003

Page 1: ...All specific subject to change without notice The information contained herein is for reference only and does not constitute a warrant of performance 30 SEP 10 UBI 5156 Rev G Equivalent to NSN 6130 01...

Page 2: ...bility Information and descriptions contained in this manual are the property of Ultralife Corporation Distribution and or reproduction in part or in whole are expressly forbidden without written cons...

Page 3: ...7 2 1 6 Wide Range Input Voltage 7 2 1 7 Conditioning Cycle 7 2 1 8 Product Name Plate 7 2 1 9 Equipment Provided 8 2 2 PHYSICAL DESCRIPTION 8 2 3 FUNCTIONAL DESCRIPTION 8 2 3 1 Charge Supply 9 2 3 2...

Page 4: ...e before proceeding CAUTION Caution statements denote a hazard They identify practices procedures or conditions that could result in damage to or destruction of this product or other equipment or prop...

Page 5: ...low been dropped or otherwise damaged in any way take it to a qualified repair technician for servicing Do not expose the unit to wet conditions rain or snow with the lid open Use of an attachment not...

Page 6: ...phic destruction of a battery While inherently safe if the CH0003 is used incorrectly an accident can occur Misuse of the CH0003 may result in damage to the battery and or the CH0003 battery charger 2...

Page 7: ...nd waits until the battery cools down before going into fast charge If the battery gets above 65 C while charging the charger will suspend the charge until the battery cools down and then go back into...

Page 8: ...the CH0003 Charger Conditioner is an AC power cable and this technical manual 2 2 Physical Description The CH0003 is 635mm 25 L x 508mm 20 W x 229mm 9 D and weighs approximately 15kg 33 lbs Figure 2...

Page 9: ...ed The battery detection circuit discharge switches battery charge indicator LEDS and charge circuitry are all located on these boards Each module provides the necessary voltage current parameters to...

Page 10: ...cations chapter for input power capabilities of the CH0003 WARNING Never alter AC cord or plug provided Improper connection can result in a risk of an electrical shock The temporary adapter should onl...

Page 11: ...ltralife 6 hours BB 2590 U Lithium ion Bren Tronics 6140 01 490 4316 6 hours UBBL09 Lithium ion Ultralife 6 hours UBBL02 UBI 2590 Lithium ion Ultralife 6140 01 553 3527 6 hours NOTE If a battery type...

Page 12: ...on contained herein is for reference only and does not constitute a warrant of performance 30 SEP 10 UBI 5156 Rev G Page 12 of 16 Figure 3 CH0003 Operation Panel Figure 4 LED Indicators 3 6 1 Green LE...

Page 13: ...wo green LEDs labeled CHARGING indicate the state of charge a section of the battery is in One indicator is for each section of the battery Solid green Indicates the battery is fast charging Extinguis...

Page 14: ...sections 4 1 1 Dirt and Dust All external components to the CH0003 can be cleaned with a water dampened non abrasive cloth and allowed to air dry or wipe dry with a clean dry non abrasive cloth 4 1 2...

Page 15: ...any defect failure or damage caused by improper use or inadequate maintenance and care Ultralife shall not be obligated to provide service under this warranty to repair service or modify these product...

Page 16: ...5 inches Depth 229mm 9 inches Weight without Battery 15kg 33 lbs Table 2 LED Indicators Indicator Meaning Flashing Green Pre charge Condition Steady Green Fast Charge Green LED Off Fast Charge Complet...