PUMP FOR HYDRAULIC SYSTEMS
-
page 15
of 75
Installation and Maintenance Manual
ULTRAFLEX
E
N
G
L
ISH
3
Screw the fittings (3) on the pump with a torque of
50 Nm (36,9 lb ft) by using an open end wrench 22 mm.
CAUTION
Do not use Teflon, Loctite or similar products on the
fitting thread since they have a seal.
5 Position the pump (2) on the dashboard front
side (5) and fix it by inserting the 4 washers (6)
and by tightening the 4 self-locking nuts (7) with
a 17 mm wrench and a torque of 16 Nm (11,8
lb ft).
2
6
7
5
WARNING
Install the pump by positioning the filling hole
(8) towards the top (see the picture) for the right
pump operation and to allow filling and purging
the system completely (see par. 3.7).
8
4 By using the proper template provided with
KIT KIM56, make the holes (4) required by the
installation in the suitable position on the
dashboard.
4
6
7
7
6
6
7
If the self-locking nuts are disassembled (7), they
must be replaced. (Contact our assistance
service, see page 6).
CAUTION
System fitting
Connection for additional
station
System fitting
Connection
for
additional station
3
3