UPT Series Easy Melt
Operation Manual
Version 1.2 12
www.ultraflexpower.com
3
LED [Red]
Illuminate when the system is in “Alarm” state
INDICATOR
4
LED [Green] - when
generator is heated ON
LED [Green] - Illuminated when HF generator is switched ON
INDICATOR
5
4 Large 7 segment
LEDs display
4 Large 7 segment LEDs display:
-
Output set point (% )
-
Timer (minutes) or “OFF”
-
Temperature (°C) if Thermo regulator is switched ON
-
Inverter current (Arms)
-
Inverter output voltage (V rms)
-
Inverter output power (kVA)
-
Output frequency (kHz)
INDICATOR
6 LED [RED] - timer status LED [RED] - Illuminated when Indicator 4 shows timer status
INDICATOR
7
LED [RED] - output
set point power in %
LED [RED] - Illuminated when Indicator 4 shows output set point
power in %
INDICATOR
8
LED [RED]
LED [RED] – Illuminated, when the Thermo regulator is switched
ON from System menu (Figure 2.6)
INDICATOR
9
“UP” and “DOWN”
arrow buttons
“UP” and “DOWN” arrow buttons – dual function
-
changing value of parameters
-
scrolling through the menus
CONTROL
10
“SELECT” button
“SELECT” button:
- scrolling through the parameters, entering menus and confirming
parameter’s value
CONTROL
2.2.3
REGULATION MODES AND SYSTEM STATUSES
-
Device works in power regulation mode only;
-
Thermo regulator ON needs to be set from SYSTEM menu to allow work with external thermocouple type-K.
Otherwise Thermo regulator must be OFF;
-
Water Flow (
Figure2.6)
must be set to Zero (factory setting).