background image

   13 PIN CONNECTOR 

SYSTEM PROGRAMMING - 

Menu 1

PAGE 12

80 SERIES

INSTALL  MANUAL

 SYSTEM WIRING DETAILS

PARK BRAKE INPUT. M SERIES REMOTE STARTER ONLY. 

YELLOW

BROWN

GRAY

RED/WHT

ORG/WHT

WHT/VIO

PINK

GRN/WHT

 BLUE/WHT

BLUE

PURPLE

GREEN

OUTPUT FOR FACTORY ALARM RE-ARM

OUTPUT FOR FACTORY ALARM DIS-ARM

NEGATIVE  STARTER OUTPUT

OUTPUT FOR TRUNK RELEASE ACTIVATION

 NEGATIVE ACCESSORY OUTPUT/ AUXILIARY OUTPUT 2

AUXILIARY OUTPUT 1/ PROGRAMMABLE OUTPUT

BRAKE SWITCH INPUT (+) WHEN BRAKE IS PRESSED

HOOD PIN SWITCH INPUT

 TACH WIRE INPUT 

WAIT TO START (DIESEL VEHICLES)

POSITIVE DOOR PIN INPUT (ALARMS AND MANUAL* ONLY)

NEGATIVE DOOR PIN INPUT (ALARMS AND MANUAL* ONLY)

BLK/WHT

*MANUAL TRANSMISSION MODEL REQUIRED

SEE OWNERS MANUAL FOR RESERVATION 

MODE PROCEDURE.

1-YELLOW          Re-arm(-)

 (Programmable) - Supplies one .75 second pulse when 

locked and one .75 second pulse after remote start shutdown. Factory alarm re-arm/ RAP 
shutdown.

2-BROWN           Dis-arm(-)

  - .75 second pulse when unlock button is pressed and one 

.75 second pulse before remote start activation. For factory alarm dis-arm/ “wake up”.

3-GRAY      

         

(-) Start/ Crank - 

Negative output during crank/ start.

4-RED/WHITE     Trunk Release(-)

 (Programmable)- Output will activate when the 

Unlock button is held for at least 3 seconds. The output will stay on for 5 seconds or until 
the button is released

5- ORG/WHT       2nd Acc (-) / Auxiliary Output 2 

(Programmable) - Ground output at 

the same time as the primary Accessory. output. This output can be programmed to 
activate as and auxiliary output when the unlock and start buttons are held. 

6- WHT/VIOLET  Auxiliary Output 1/ Programmable Output 

 - Auxiliary output when 

the # button is held. Programmable to (-) Ignition/ Car Finder and Dome Light Supervision 
with Car Finder. 

(Car Finder and Auxiliary 1 are not available on 2way models)

7- PINK               Brake Switch input (+) - 

This wire must be connected to the wire at the 

brake switch that changes to 12volts when the brake is pressed. 

   

Manual Transmission Only. - 

Alarm & Manual Transmission Only. - 

*Connect to door pin for Passive Arming on non alarm models.

8- BLACK/WHT  Park Brake Input (-) 

Connect to the 

Park Brake wire. Must be connected on manual transmission models.  

9- GREEN/WHT  Hood Pin Input (-) - 

Connect

 

this wire to the supplied hood pin switch. 

If ground is detected on this input the remote starter will not activate.

10- BLUE/WHT   Tach Wire Input (A/C) - 

This wire is

 

used to

 

 to detect when the vehicle 

has started. The Tach source is typically taken from a fuel injector, coil, coil pack or crank 
position sensor. The Tach wire is generally found as the opposite from the common wire 
at the coil or fuel injector.

11- BLUE             Wait to Start Input (+ or -) 

(Programmable) - On diesel vehicles 

connect this wire to the wait to start or glow plug wire. The system will wait for the input to 
turn off then remote start. A start delay may also be programmed to avoid this connection.

12- PURPLE        Positive Door Input (+) Alarm & Manual Transmission Only. - 

Connect this wire to the door pin switch if it changes to 12volts when the door is opened. 
*Connect to door pin for Passive Arming on non alarm models.

13- GREEN          Negative Door Input (+) 

Connect this wire to the door pin switch if it changes to Negative when the door is 
opened. 

SYSTEM PROGRAMMING - 

Menu 1

PAGE 13

80 SERIES

INSTALL MANUAL

 SYSTEM WIRING DETAILS

Summary of Contents for 80 Series

Page 1: ...ding interference that may cause undesired operation CAUTION Changes or modifications not expressly approved by the part responsible for compliance void the user s authority to operate this devise www...

Page 2: ...9 Enter Program Mode System Reset Menu 1 2 3 4 Quick View SYSTEM WIRING DETAILS 10 14 Connector Views Wiring Description PROGRAM MENUS 15 23 Program Menu 1 Detailed Program Menu 2 Detailed Program Men...

Page 3: ...TION INPUT CONNECT TO COIL INJECTOR BRAKE SWITCH INPUT 12VOLT WHEN BRAKE IS PRESSED HOOD PIN SWITCH GROUND WHEN HOOD IS OPENED PARK BRAKE INPUT M SERIES ONLY NEGATIVE DOOR INPUT WHEN DOOR OPENED Statu...

Page 4: ...tem with the Fortin module connected to the data port to set the default to Fortin bypass module 1 2 3 4 SELECTABLE PARK LIGHT OUTPUT GROUND OUTPUT FOR ADDITIONAL SENSOR FULL TRIGGER FOR ALARM MODELS...

Page 5: ...YPES THE DEFAULT SETTING IS FOR IDATALINK MODULES THE SECOND IS FOR FORTIN BYPASS MODULES IF THE BYPASS KIT IS A IDATA PRODUCT SIMPLY CONNECT TO THIS INPUT AND PROGRAM THE BYPASS MODULE AS PER THE INS...

Page 6: ...E S Hybrid mode 1 This option requires a tach connection Once the vehicle starts the system will not monitor the tach input and stay running for 15 minutes Hybrid Mode 2 No Tach wire connection This s...

Page 7: ...Program Switch to advance through the settings Confirmed by Park Lights Horn Siren chirps LED flashes 5 Press and hold the Program Switch to change the setting Confirmed by Park Lights Horn Siren chir...

Page 8: ...S ENABLED 8 PASSIVE ARMING PASSIVE ST KILL FULL PASSIVE ARMING ENABLED PASSIVE SAFETY REARM ENABLED 9 ALARM SHOCK AUX SENSOR INTERNAL SHOCK DISABLED BOTH SENSORS DISABLED BOTH SENSORS ENABLED ACTIVE A...

Page 9: ...4 Flashes 4 Chirps SYSTEM PROGRAMMING Menu 1 SYSTEM PROGRAMMING Menu 1 7 LEDS FLASH WHEN LOCKED ARMED LED FLASHES LEDS DO NOT FLASH WHEN LOCKED ARMED AUTO TACH TACHLESS SETTING LED FLASHES SETTING DES...

Page 10: ...WN BLUE OUTPUT TO ACTIVATE IGNITION CIRCUIT WHITE SELECTABLE OUTPUT DEFAULT SECOND IGNITION RED 30A HIGH CURRENT 12VOLT INPUT YELLOW OUTPUT TO ACTIVATE START CIRCUIT RED 30A HIGH CURRENT 12VOLT INPUT...

Page 11: ...iren on alarm models Programmable Connect to the negative horn wire on the vehicle for non alarm models Connect to wire on the siren Red or Brown for alarm models PIN 2 ORANGE Starter Kill Anti Grind...

Page 12: ...PUT FOR FACTORYALARM DIS ARM NEGATIVE STARTER OUTPUT OUTPUT FOR TRUNK RELEASEACTIVATION NEGATIVEACCESSORYOUTPUT AUXILIARYOUTPUT 2 AUXILIARYOUTPUT 1 PROGRAMMABLE OUTPUT BRAKE SWITCH INPUT WHEN BRAKE IS...

Page 13: ...pressed Manual Transmission Only Alarm Manual Transmission Only Connect to door pin for Passive Arming on non alarm models 8 BLACK WHT Park Brake Input Connect to the Park Brake wire Must be connecte...

Page 14: ...hen the remote starter is activated this wire will switch to ground 2 BLACK Wire System Ground Connect this wire to the ground input on the bypass module 3 RED Wire 12volt Output LOW CURRENT Connect t...

Page 15: ...EN Chirps 3 times 1 ENTER SHOCK SENSOR ADJUSTMENT MODE 2 ADJUSTING THE SHOCK SENSOR 3 EXITING SENSOR ADJUSTMENT MODE Note System will Arm or Disarm via silent arming prior to entering adjustment mode...

Page 16: ...and goto step 6 Press Release BUTTON 4 on Remote to be Programmed for 2ND CAR OR PAD LOCK HORN will honk 1 time to confirm remote has been programmed If the HORN does not honk press button again HORN...

Page 17: ...FF Press and release the Program Button Step 2 The system will respond with three park light flashes and the HORN optional will honk the same number of times as the events in memory Maximum four event...

Page 18: ...12volts 87 86 85 87a 30 87 86 85 87a 30 Alarm and or Starter Module Door lock Output Blue Green Vehicle s Lock Unlock Switch USE SPDT 12v Relay POSITIVE DOOR LOCK LOW CURRENT 12volts 12volts 87 86 85...

Page 19: ...dule Door lock Output Blue Green Unlock Resistor Lock Resistor Lock Unlock Switch USE SPDT 12v Relay REVERSE POLARITY DOOR LOCK SYSTEM 12volts 12volts Alarm and or Starter Module Door lock Output Blue...

Page 20: ...horized dealer but have been registered please fill out the service request form at http www ultrastarters com wiring_diagrams html PRODUCT INFORMATION www ultrastarters com TECHNICAL SUPPORT support...

Reviews: