INSTALL  MANUAL

  SYSTEM WIRING DETAILS

WHITE

SYSTEM GROUND INPUT

JUMPER SELECTABLE PARK LIGHT OUTPUT (+ OR -)

(+) SIREN/  HORN OUTPUT (-)  

STARTER-KILL/ ANTI-GRIND OUTPUT

BLACK

ORANGE

BROWN

BLUE

OUTPUT TO ACTIVATE IGNITION CIRCUIT

WHITE*

SELECTABLE OUTPUT (DEFAULT SECOND IGNITION)

RED

30A HIGH CURRENT 12VOLT INPUT

YELLOW

OUTPUT TO ACTIVATE START CIRCUIT 

RED

30A HIGH CURRENT 12VOLT INPUT 

GREEN

OUTPUT TO ACTIVATE ACCESSORY/ HEATER CIRCUIT

BLUE

NEGATIVE OUTPUT FOR UNLOCK

 

12+ OUTPUT FOR DOOR LOCK MODULE 

GREEN

NEGATIVE OUTPUT FOR UNLOCK

 

  4 PIN AUXILIARY SENSOR CONNECTOR

SYSTEM PROGRAMMING - 

Menu 1

PAGE 11

80 SERIES

INSTALL MANUAL

  SYSTEM WIRING DETAILS

PIN-1 YELLOW   Starter Output-

This wire will test 0V when the key is off, in the Accessory position and when 

the Ignition is in the on position. The starter wire is 12volts during the start/ crank position only.

PIN-2 GREEN      Heater/Acc Output-

This wire will test 0V when key is off, 12volts in the ACC and IGN 

positions and off during start/ crank position.

PIN-3 RED           12volt Input(30amp)- 

This input supplies the 12volt power for the Ignition, Park Lights  and 

the Selectable output. 

PIN-4 RED           12volt Input(30amp)- 

This input supplies the 12volt power for the Accessory and Starter 

outputs. 

PIN-5 WHITE       Selectable Output - 

2nd Ignition, Accessory or Start output. Programmable.

Note: This output does not switch to default when the system is reset. 

PIN-6 BLUE         Ignition Output- 

This wire will test 0V in the off and Accessory positions the switch to12volts 

in the Ignition and Start positions.

PIN-1 BROWN           (-) Horn/ (Siren on alarm models) (Programmable)- 

Connect to the negative horn wire 

on the vehicle for non alarm models. Connect to (+) wire on the siren (Red or Brown) for alarm models.

PIN-2 ORANGE         Starter Kill/ Anti-Grind- 

This wire can be connected to an additional relay to disable the 

start circuit when the lock button is pressed. The output will also stay on when remote started, this will prevent 
the starter motor from being re-engaged while the vehicle is running.

PIN-3 WHITE             Jumper Selectable Park Light Output (+ or -)- 

Connect to the vehicles positive park light 

wire or change the jumper and connect to the vehicle negative park light wire. The default position of the jumper 
is 

Positive Park light Output.

PIN-4  BLACK

           

System Ground Input- 

Connect to chassis ground.

PIN 1- GREEN-          Negative Lock Output

Connect to lock wire from the switch on vehicles with a negative type switch. **LOW CURRENT ONLY**

 

PIN 2- 12volt Output for Door Lock Module

This output will supply 12volts for a plug-in type door lock module. Do not use this input to power-up relays 
**LOW CURRENT ONLY**

PIN 3- BLUE-             Negative Unlock Output

Connect to lock wire from the switch on vehicles with a negative type switch. **LOW CURRENT ONLY**

  

 6-PIN CONNECTOR

 

  4-PIN CONNECTOR

Summary of Contents for 80 Series

Page 1: ...ding interference that may cause undesired operation CAUTION Changes or modifications not expressly approved by the part responsible for compliance void the user s authority to operate this devise www...

Page 2: ...9 Enter Program Mode System Reset Menu 1 2 3 4 Quick View SYSTEM WIRING DETAILS 10 14 Connector Views Wiring Description PROGRAM MENUS 15 23 Program Menu 1 Detailed Program Menu 2 Detailed Program Men...

Page 3: ...TION INPUT CONNECT TO COIL INJECTOR BRAKE SWITCH INPUT 12VOLT WHEN BRAKE IS PRESSED HOOD PIN SWITCH GROUND WHEN HOOD IS OPENED PARK BRAKE INPUT M SERIES ONLY NEGATIVE DOOR INPUT WHEN DOOR OPENED Statu...

Page 4: ...tem with the Fortin module connected to the data port to set the default to Fortin bypass module 1 2 3 4 SELECTABLE PARK LIGHT OUTPUT GROUND OUTPUT FOR ADDITIONAL SENSOR FULL TRIGGER FOR ALARM MODELS...

Page 5: ...YPES THE DEFAULT SETTING IS FOR IDATALINK MODULES THE SECOND IS FOR FORTIN BYPASS MODULES IF THE BYPASS KIT IS A IDATA PRODUCT SIMPLY CONNECT TO THIS INPUT AND PROGRAM THE BYPASS MODULE AS PER THE INS...

Page 6: ...E S Hybrid mode 1 This option requires a tach connection Once the vehicle starts the system will not monitor the tach input and stay running for 15 minutes Hybrid Mode 2 No Tach wire connection This s...

Page 7: ...Program Switch to advance through the settings Confirmed by Park Lights Horn Siren chirps LED flashes 5 Press and hold the Program Switch to change the setting Confirmed by Park Lights Horn Siren chir...

Page 8: ...S ENABLED 8 PASSIVE ARMING PASSIVE ST KILL FULL PASSIVE ARMING ENABLED PASSIVE SAFETY REARM ENABLED 9 ALARM SHOCK AUX SENSOR INTERNAL SHOCK DISABLED BOTH SENSORS DISABLED BOTH SENSORS ENABLED ACTIVE A...

Page 9: ...4 Flashes 4 Chirps SYSTEM PROGRAMMING Menu 1 SYSTEM PROGRAMMING Menu 1 7 LEDS FLASH WHEN LOCKED ARMED LED FLASHES LEDS DO NOT FLASH WHEN LOCKED ARMED AUTO TACH TACHLESS SETTING LED FLASHES SETTING DES...

Page 10: ...WN BLUE OUTPUT TO ACTIVATE IGNITION CIRCUIT WHITE SELECTABLE OUTPUT DEFAULT SECOND IGNITION RED 30A HIGH CURRENT 12VOLT INPUT YELLOW OUTPUT TO ACTIVATE START CIRCUIT RED 30A HIGH CURRENT 12VOLT INPUT...

Page 11: ...iren on alarm models Programmable Connect to the negative horn wire on the vehicle for non alarm models Connect to wire on the siren Red or Brown for alarm models PIN 2 ORANGE Starter Kill Anti Grind...

Page 12: ...PUT FOR FACTORYALARM DIS ARM NEGATIVE STARTER OUTPUT OUTPUT FOR TRUNK RELEASEACTIVATION NEGATIVEACCESSORYOUTPUT AUXILIARYOUTPUT 2 AUXILIARYOUTPUT 1 PROGRAMMABLE OUTPUT BRAKE SWITCH INPUT WHEN BRAKE IS...

Page 13: ...pressed Manual Transmission Only Alarm Manual Transmission Only Connect to door pin for Passive Arming on non alarm models 8 BLACK WHT Park Brake Input Connect to the Park Brake wire Must be connecte...

Page 14: ...hen the remote starter is activated this wire will switch to ground 2 BLACK Wire System Ground Connect this wire to the ground input on the bypass module 3 RED Wire 12volt Output LOW CURRENT Connect t...

Page 15: ...EN Chirps 3 times 1 ENTER SHOCK SENSOR ADJUSTMENT MODE 2 ADJUSTING THE SHOCK SENSOR 3 EXITING SENSOR ADJUSTMENT MODE Note System will Arm or Disarm via silent arming prior to entering adjustment mode...

Page 16: ...and goto step 6 Press Release BUTTON 4 on Remote to be Programmed for 2ND CAR OR PAD LOCK HORN will honk 1 time to confirm remote has been programmed If the HORN does not honk press button again HORN...

Page 17: ...FF Press and release the Program Button Step 2 The system will respond with three park light flashes and the HORN optional will honk the same number of times as the events in memory Maximum four event...

Page 18: ...12volts 87 86 85 87a 30 87 86 85 87a 30 Alarm and or Starter Module Door lock Output Blue Green Vehicle s Lock Unlock Switch USE SPDT 12v Relay POSITIVE DOOR LOCK LOW CURRENT 12volts 12volts 87 86 85...

Page 19: ...dule Door lock Output Blue Green Unlock Resistor Lock Resistor Lock Unlock Switch USE SPDT 12v Relay REVERSE POLARITY DOOR LOCK SYSTEM 12volts 12volts Alarm and or Starter Module Door lock Output Blue...

Page 20: ...horized dealer but have been registered please fill out the service request form at http www ultrastarters com wiring_diagrams html PRODUCT INFORMATION www ultrastarters com TECHNICAL SUPPORT support...