background image

Green

Green

Green

Red

Red

Blue

Blue

Blue

Black

Pink

Pink

Door Lock Output

Door Unlock Output

12vts Low Current

Priority Output

(-)500ma Output

(-)500ma Output

(-)500ma Output

(+)500ma Output

Programmable

- See menu 1, Setting 3

Programmable

- See menu 1, Setting 3

Programmable

- See menu 1, Setting 3

12vt inverter Output-Low Current

Sensor Full - Warn

Sensor Pre - Warn
Sensor Ground

Sensor Power

(-) When Disarmed

Horn / Channel 5.
(+) Disconnect

(-)500ma Output

(-)500ma Output

(+)500ma Input

(-)500ma Input

(-)500ma Input

(-)500ma Output

(+)500ma Output

Negative Output When Disarmed

Programmable

- See menu 2, Setting 7

Triggers when 12vt circuit is broken

Negative trigger input

Negative trigger input

Sensor ground output

Sensor power output

-

-

2 PIN RED

2 PIN BLUE

4 PIN RED

4 PIN WHITE

4 PIN WHITE

3 PIN WHITE

SIDE VIEW

SATELLITE LINK PLUG

LED

Valet Switch

Main

Alar

m

Har

ness

(-) Trunk Release Output

Grey

(-) Trunk Release

500ma Output

Connect to chassis ground

Black

Ground

(-) Input

Connect to main Ignition 

Yellow

Ignition Input

(+) Input

 12vt constant  power

Red

Main Power

(+) Input

Pink

Channel 4

500ma Output

Programmable

 - Menu 2

Green

(-) Door Input

(-) Input

Connect to (-) door pin

Purple

(+) Door Input

(+) Input

Connect to (+) door pin

Blue

Hood Input

(-) Input

Connect to hood pin

Brown

(+) Siren

3amp Output

Connect to Siren

White

(+) Park Lights

15amp Output

Connect to park lights

Blk/White

Dome Light Relay

(+.-) Output

See page. 4

Blk/White

Dome Light Relay

(+.-) Input

See page. 4

Orange

(-) When Armed

500ma Output

(-) Output while armed

**500ma outputs are low current and are designed to activate relays.

Built-in Starter Disable relay (Normally Connected 87a & 30).

See page. 5

Starter
Disable

Wiring Diagram

PAGE 3

SECURITY SYSTEM

INSTALL GUIDE

Summary of Contents for 600 SERIES

Page 1: ...armful interference and 2 This device must accept any interference received including interference that may cause undesired operation CAUTION Changes or modifications not expressly approved by the par...

Page 2: ...Additional sensor input Installation Page 6 7 Basic Installation Quick start Shock Sensor Programming Test The System Programming Page 7 9 Program Overview System Reset Program Menu 1 User Settings Pr...

Page 3: ...4 PIN RED 4PINWHITE 4PINWHITE 3PINWHITE SIDE VIEW SATELLITE LINK PLUG LED Valet Switch Main Alarm Harness Trunk Release Output Grey Trunk Release 500ma Output Connect to chassis ground Black Ground In...

Page 4: ...mount the Program Button This location should be hidden and not visible from outside the vehicle Once the location of the switch is picked use a 1 4 drill bit and drill a hole Remove the nut and push...

Page 5: ...Output for voltage inverter Low Current Only Blue Door Unlock Programmable menu 1 setting 3 Pink Second Unlock Programmable menu 1 setting 3 4 Pin Connector Red 2 Pin Connector Blue 2 Pin Connector R...

Page 6: ...ed 5 Press the Unlock button to exit the Program Mode To test the Shock Sensor 1 Press the Lock button once to arm the system 2 Wait five seconds then impact the vehicle Lighter impacts to the vehicle...

Page 7: ...l be exited if there is no activity for 30 second or if the key is turned to the Off position This will be confirmed by one siren chirp and park light flash Note If unit does not enter Program Mode tu...

Page 8: ...of park light flashes and or siren chirps Release the Valet Switch Press the Valet momentarily to move to next program step or repeat to change selection Press the Valet Switch 2 times to select sett...

Page 9: ...until you receive the appropriate of park light flashes and or siren chirps Release the Valet Switch Press the Valet momentarily to move to next program step or repeat to change selection Press the V...

Page 10: ...ill come ON if park lights do not come on at this point turn key off for 5 seconds then repeat step 1 Step 3 Continue to hold the Program Switch until park lights go out Step 4 Press the LOCK button o...

Page 11: ...LED comes on solid NOTE The siren will chirp 5 times as confirmation SERVICE MODE DEACTIVATED 1 Press and release button 4 then hold Button 4 again for 6 seconds until status LED turns of NOTE The sir...

Page 12: ...d when ignition is turned ON For proper memory clearing insure to connect the ignition input to the ignition on the vehicle Alarm Diagnostics Diagnostics Chart Diagnostics Additional LED Flashes Park...