Installation Guide
WIRING CONNECTORS
5
WIRING CONNECTORS
Yellow
Starter
30amp output
12volts during crank only.
Green
Heater
30amp output
12volts in accessory. Off during start.
Red
12 power
30amp input
Constant 12volt power at ignition harness.
Red
12 power
30amp input
Constant 12volt power at ignition harness.
Blue
Ignition 1
30amp output
12volts in ignition and start positions.
White
Selectable
30amp output
Jumper Selectable.
See Page 5.
Yellow
Re-Arm
0.75sec Pulse With Lock And On Shutdown.
Orange
(-) Output
Negative While Locked -
**
Starter Program Mode
.
Brown
Disarm
0.75sec Pulse With Unlock And Before Start.
Red/White
3rd CH
Trunk Release - Active When The Unlock Button Is Held For 3seconds.
White/Violet
(-)Running Negative Output While Running.
Green
(-) Door
Negative Door Trigger Input -
Manual Trans And Alarm Units Only.
Purple
(+) Door
Positive Door Trigger Input -
Manual Trans And Alarm Units Only.
Green/White
Hood Pin
Negative Hood Pin Input -
MUST BE CONNECTED!!
Pink
Brake
Positive Brake Input -
MUST BE CONNECTED!!
Black
Ground
System Ground Input -
MUST BE CONNECTED!!
Blue/White
Tach
Tach Signal Input
-
MUST BE CONNECTED!!
Blue
Glow Plug
Negative Glow Plug Input -
DIESEL ENGINE ONLY. **Starter Program Mode.
White
Park Lights Positive Park light Output -
10 Amp Max.
Black/White
Park Brake Negative Park Brake Input -
Manual Transmission Models Only.
6 Pin Power Connector
14 Pin Connector
5
White/Green
Channel 4
Programmable
- See Alarm Settings.
Menu 2.
Black
Dome Light Negative Output For Dome Light Supervision.
White/Blue
Siren
Positive Output For Siren.
Red
Trunk Pin
Negative Input for Trunk Pin.
Green
Door Lock
Door Lock Output -
Programmable - Menu 1 Setting 3.
Red
12 Volts
Low Current Output.
Use With Voltage Inverter
Blue
Door Unlock
Door Unlock Output -
Programmable - Menu 1 Setting 3.
Pink
2nd Unlock
Door Unlock Output -
Programmable - Menu 1 Setting 3.
4 Pin Connector Square
4 Pin Connector Red
Jumper Selections
3 Pin Connector White
Green
(-) Disarmed
Negative Output When The System Is Disarmed.
Pink
Horn/5th Channel
Programmable Output.
Blue
(+) Disconnect
(+) Disconnect Or Instant Start Trigger.
The jumpers control the output on the white wire from the
six pin harness. Place the jumpers in the above order to
change the output.
Note: The default setting is second ignition.
Output on White wire Jumper position
Second Starter Position 1
Second Accessory Position 2
Second Ignition Position 3
Back View Of Module
Jumpers
3 2 1