background image

DOOR LOCK DIAGRAMS

Green

Vehicle's Lock/Unlock Switch

To Control 
Relay or
Actuators

NEGATIVE DOOR LOCK 

(LOW CURRENT)

Alarm and / or Starter

Module

Door lock Output

SYSTEM PROGRAMMING - 

Menu 1

PAGE 14

INSTALL  MANUAL

  RELAY DIAGRAMS

Vehicle's Lock/
Unlock Switch

USE SPDT 12v Relay

Blue

NEGATIVE DOOR LOCK 

(LOW CURRENT)

Ground

Ground

12volts

12volts

87

86

85

87a

30

87

86

85

87a

30

Alarm and / or Starter

Module

Door lock Output

Blue

Green

Vehicle's Lock/
Unlock Switch

USE SPDT 12v Relay

POSITIVE DOOR LOCK 

(LOW CURRENT)

12volts

12volts

87

86

85

87a

30

87

86

85

87a

30

Alarm and / or Starter

Module

Door lock Output

Blue

Green

POSITIVE TYPE USING

 INVERTER

Alarm and / or Starter

Module

Door lock Output

Blue

Green

VP-1

INVERTER

Vehicle's Lock/ Unlock Switch

Blue

Green

72 SERIES

SYSTEM PROGRAMMING - 

Menu 1

PAGE 15

INSTALL MANUAL

  RELAY DIAGRAMS

Vehicle's Lock/
Unlock Switch

USE SPDT 12v Relay

NEGATIVE ONE WIRE 

DOOR LOCKS

Ground

Ground

12volts

12volts

87

86

85

87a

30

87

86

85

87a

30

Alarm and / or Starter

Module

Door lock Output

Blue

Green

Unlock Resistor

Lock Resistor

                Lock/ Unlock Switch

USE SPDT 12v Relay

REVERSE POLARITY DOOR

LOCK SYSTEM

12volts

12volts

Alarm and / or Starter

Module

Door lock Output

Blue

Green

87

86

85

87a

30

87

86

85

87a

30

x

x

x

x

USE SPDT 12v Relay

AFTER-MARKET DOOR 

LOCK ACTUATORS

12volts

12volts

Alarm and / or Starter

Module

Door lock Output

Blue

Green

87

86

85

87a

30

87

86

85

87a

30

Ground

Ground

DOOR LOCK DIAGRAMS

72 SERIES

Summary of Contents for 1172 SERIES

Page 1: ...nce that may cause undesired operation CAUTION Changes or modifications not expressly approved by the part responsible for compliance void the user s authority to operate this devise REV 2011 7 22 72...

Page 2: ...Light Ground Connector 3 Pin Lock Unlock Connector 3 Pin Bypass Module Connector 9 Pin Connector Transmitter Programming Page 8 Programming Remote Transmitters Program Mode Page 9 Enter Program Mode...

Page 3: ...MAIN POWER INPUT RED OUTPUT TO ACTIVATE THE STARTER CIRCUIT YELLOW 12VOLT 30 AMP MAIN POWER INPUT RED OUTPUT TO ACTIVATE ACCESSORY CIRCUIT THE GREEN AUXILIARY 1 OUTPUT HOLD PROGRAMMABLE BLACK TRUNK R...

Page 4: ...ELAYS OVERLOADING THIS OUTPUT WILL DAMAGE THE MODULE FOR USE WITH COMPATIBLE BYPASS MODULES ONLY BY DEFAULT THE SYSTEM COMES WITH THE PARK LIGHT JUMPER SET FOR POSITIVE PARK LIGHT OUTPUT TO CHANGE THE...

Page 5: ...for 15 minutes Hybrid Mode 2 No Tach wire connection This setting will power up the ignition wires pulse the start output for 2 seconds then stay on run for 15 minutes See Program Menu 4 Hybrid Mode 1...

Page 6: ...ns then switch to12volts in the Ignition and Start and run position SELECTABLE OUTPUT 2nd Ignition Accessory or Start output Programmable Note This output does not switch to default when the system is...

Page 7: ...ton is held Programmable for Dome light Output or 2nd Unlock Output Connect this wire to the supplied hood pin switch If ground is detected on this input the remote starter will not activate Programma...

Page 8: ...p 6 Press Release BUTTON 4 on Remote to be Programmed for 2ND CAR OR PAD LOCK HORN will honk 1 time to confirm remote has been programmed If the HORN does not honk press button again HORN will honk 1...

Page 9: ...ogram Switch for 5 seconds or until the Horn Chirps 3 times 4 Turn the ignition key OFF to exit 4 Press and Release the Program Switch to advance through the settings The horn will chirp and LEDs flas...

Page 10: ...HIRPS OPTION 3 3 CHIRPS 1 2 3 4 5 6 9 NA IGNITION AUTO LOCK IGNITION AUTO LOCK UNLOCK IGNITION AUTO LOCK ONLY HORN SETTINGS HORN CHIRPS DISABLED HORN CHIRPS ENABLED DOOR LOCK PULSE OPTIONS DOUBLE UNLO...

Page 11: ...LUG OR 20 SECONDS DELAY POSITIVE TRIGGER TO START 2 PULSES GAS POSITIVE GLOW PLUG RE ARM OPTIONS PULSE WITH LOCK PULSE AFTER START DEFROST SEAT PULSE WITH LOCK AFTER SHUTDOWN RUNTIME 4 MINUTE RUNTIME...

Page 12: ...nd release the Program Button Step 2 The system will respond with three park light flashes and the HORN optional will honk the same number of times as the events in memory Maximum four events four hon...

Page 13: ...E UNLOCK BUTTON WILL UNLOCK THE DOORS THEN THE NEXT TIME YOU PRESS THE BUTTON THE DOORS WILL LOCK WHEN PROGRAMMED FOR 2 BUTTON OR LOCK UNLOCK TOGGLE PRESSING UNLOCK AND START AT THE SAME TIME WILL SEL...

Page 14: ...GATIVE DOOR LOCK LOW CURRENT Ground Ground 12volts 12volts 87 86 85 87a 30 87 86 85 87a 30 Alarm and or Starter Module Door lock Output Blue Green Vehicle s Lock Unlock Switch USE SPDT 12v Relay POSIT...

Page 15: ...lock Output Blue Green Unlock Resistor Lock Resistor Lock Unlock Switch USE SPDT 12v Relay REVERSE POLARITY DOOR LOCK SYSTEM 12volts 12volts Alarm and or Starter Module Door lock Output Blue Green 87...

Page 16: ...orized dealer but have been registered please fill out the service request form at http www ultrastarters com wiring_diagrams html PRODUCT INFORMATION www ultrastarters com TECHNICAL SUPPORT support u...

Reviews: