Service 

Water flows into the valve at the top, down through the resin and then up through the ‘riser’ 
tube in the middle of the vessel. As the water travels through the resin the ion exchange takes 
place. The controllers are set to automatically regenerate on capacity. The display on the 
control will show the following; In service and the remaining capacity. 
 

Routine Maintenance 

To ensure the reliability of your softener it is important to follow routine maintenance steps: 

 

Check salt level (this may need to be done regularly dependent on consumption) 

 

The salt level should always be kept above the water level 

 

Check there is no sign of damage or leaks 

 
Programming The Valve In Case Of Memory Loss 

Should the programming have been lost in transit the following instructions in conjunction with 
the setting sheet will allow you to re set it. When the power has been connected the valve will 
display the valve model and initialise itself and then display TIME; you can then start to 
program the valve. Selections are made using the UP and DOWN buttons until the required 
setting is displayed. After each setting press CONFIRM to continue.  

 
Set Time of Day 

If the time of day is not already showing on the screen, press CONFIRM, scroll to ‘Set Clock’ 
and press CONFRIM. Adjust the hours and press CONFIRM to adjust the minutes, press 
CONFIRM to take you back to the menu, then press RETURN to show main display.  

 
Step 1: Cycle Sequence 

Press CONFIRM to bring up the menu. Scroll down to ‘Advanced Settings’ and press CONFIRM. 
Scroll down to find the following options; Set Backwash Time, Set Brine & Rinse, Set Brine Refill, 
Set Fast Rinse. Press CONFIRM on the option you would like to change.  
 

Suggested Default Settings: Backwash Time – 3 Mins. Brine Draw & Rinse – 45 Mins, Brine 

Refill – 1.5/2.5 Mins, Fast Rinse – 4 Mins 

 
You can now change the time on each option by using the up and down arrows to select the 
minutes and seconds required. Once finished, press RETURN, until the main display shows. 

 

 

 

Summary of Contents for Cyan

Page 1: ...ded some of our water softners that would be suitable for you below SOFT WATER MODERATELY SOFT WATER SLIGHTLY HARD WATER MODERATELY HARD WATER HARD WATER VERY HARD WATER Your Water Softener Recommenda...

Page 2: ...e placed close to the rising main Take care to allow hard water take off points for a drinking water facility and or an outside tap The distance between the drain and the softener should be as short a...

Page 3: ...the water softener is tested to a pressure of 6 bar 87psi we recommend the fitting of a pressure limiter should your pressure exceed 4 bar 58 psi The minimum working pressure is 1 5 bar 21 7psi Start...

Page 4: ...Waste Pipe Installation Connect the waste pipe to the waste outlet on the softener and run the hose to either an up stand or outside drain a minimum air gap of 20mm must exist at the end of the drain...

Page 5: ...is please follow these instructions Using the up and down buttons scroll to Advanced Settings and Press CONFIRM Scroll down to Set Residual Water and press CONFIRM This will show you the total amount...

Page 6: ...er has been connected the valve will display the valve model and initialise itself and then display TIME you can then start to program the valve Selections are made using the UP and DOWN buttons until...

Page 7: ...now scroll up and down to change the amount of days for the override Change Regeneration Time Default At 2 00am Press CONFIRM to show menu scroll to Advanced Settings and press CONFIRM Scroll down to...

Page 8: ...r plugged D Insufficient water flowing into brine tank E Leak at oring on riser F Internal valve leak G Regeneration cycles not correct H Shortage of resin I Bad quality of feed water or turbine block...

Page 9: ...e and brine line D Stop water supply and restart program install with safety brine valve in salt tank E Repair or replace safety brine valve Pressure loss or rust in pipe A Iron in water supply pipe B...

Page 10: ...core or C sealing ring D Reduce water pressure or use pressure relief connector function Salt water going to service A Foreign material in injector or injector fails to work B Brine valve cannot be s...

Reviews: