Midnight Water 

Softener 

Product Manual 

[email protected] 

01622 933 853 

www.ultra-soft.co.uk 

Commissioning The Softener 

Put approximately 5 litres of water into the brine tank. You may also at this point put a 
quantity of salt into the tank. Do not allow the salt level in the brine tank to exceed the 
height of the overflow. You should keep the salt level above the water level and check the 
salt level on a regular basis until a usage pattern has been established. 
 

Programming The Valve 

When the softener is first plugged in the valve type will display (F79) then a few seconds 
later show the time setting screen. Use the up and down arrows to set the time and then 
press confirm (all settings except time of day are pre-programmed but should be 
adjusted where suitable, such as water hardness). 
 

Capacity Settings 

The capacity will have a default setting based on 300ppm hardness. If you wish to 
change this, please follow these instructions. Using the up and down buttons, scroll to 
‘Advanced Settings’ and Press CONFIRM. Scroll down to ‘Set Residual Water’ and press 
CONFIRM. This will show you the total amount of treated water the softener can achieve 
before regeneration. For reference the Cyan has a resin capacity of 12.5 litres. 

 
If you need to change capacity settings, follow this calculation: 
 

“Resin Capacity” x 50 ÷ “Water Hardness In PPM” 

Example (12.5 x 50) ÷ 300 = 2.08m³ 

 

Regeneration 

With the softener fully plumbed in and the valve programmed, final commissioning can 
now start. When the softener is fully functional the regeneration will happen at the pre-
set time (see programming the valve in case of memory loss section below). 
 
To initiate an immediate regeneration press and hold the RETURN button until the valve 
motor starts to turn. If during a regeneration cycle you need to skip through the cycle, 
this can be done in the following way. To skip to the next stage press the RETURN 
button and this will take it to the next stage of the regeneration, this can be repeated to 
get to the end of the regeneration cycle. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for Cyan

Page 1: ...ded some of our water softners that would be suitable for you below SOFT WATER MODERATELY SOFT WATER SLIGHTLY HARD WATER MODERATELY HARD WATER HARD WATER VERY HARD WATER Your Water Softener Recommenda...

Page 2: ...e placed close to the rising main Take care to allow hard water take off points for a drinking water facility and or an outside tap The distance between the drain and the softener should be as short a...

Page 3: ...the water softener is tested to a pressure of 6 bar 87psi we recommend the fitting of a pressure limiter should your pressure exceed 4 bar 58 psi The minimum working pressure is 1 5 bar 21 7psi Start...

Page 4: ...Waste Pipe Installation Connect the waste pipe to the waste outlet on the softener and run the hose to either an up stand or outside drain a minimum air gap of 20mm must exist at the end of the drain...

Page 5: ...is please follow these instructions Using the up and down buttons scroll to Advanced Settings and Press CONFIRM Scroll down to Set Residual Water and press CONFIRM This will show you the total amount...

Page 6: ...er has been connected the valve will display the valve model and initialise itself and then display TIME you can then start to program the valve Selections are made using the UP and DOWN buttons until...

Page 7: ...now scroll up and down to change the amount of days for the override Change Regeneration Time Default At 2 00am Press CONFIRM to show menu scroll to Advanced Settings and press CONFIRM Scroll down to...

Page 8: ...r plugged D Insufficient water flowing into brine tank E Leak at oring on riser F Internal valve leak G Regeneration cycles not correct H Shortage of resin I Bad quality of feed water or turbine block...

Page 9: ...e and brine line D Stop water supply and restart program install with safety brine valve in salt tank E Repair or replace safety brine valve Pressure loss or rust in pipe A Iron in water supply pipe B...

Page 10: ...core or C sealing ring D Reduce water pressure or use pressure relief connector function Salt water going to service A Foreign material in injector or injector fails to work B Brine valve cannot be s...