www.ultraoptics.com
page 40
Air Regulator Adjustment
1. Take off the large removable panel on the left side of the 44R.
2. Locate either of the air regulator mounted on the inner well.
3. Check that the air gauges on the regulators are reading 80 PSI.
4. If an adjustment needs to be made, pull down on the regulator adjustment cap and turn
until the air gauge reads 80 PSI.
5. Push adjustment cap back up to lock in place.
Replacement/Adjustment of the Conveyor Drive Belt
1. Remove the drive belt housing cover.
2. To replace belt
a. Loosen the tension pulley using the top bolt.
b. Pull old belt off of the assembly.
c. Attach the new belt on to the assembly
3. To tighten
a. Loosen the tension pulley using the top bolt.
b. Put pressure towards the belt on the bottom bearing side of tension pulley.
c. Tighten bolt on top of tension pulley while maintaining pressure on belt to lock
tension in place.
4. Reattach cover to drive belt housing.