Initial Start-up Step-by-step Instructions
Step 1: Select Valve Type
This step may have been performed by your system’s OEM manufacturer.
In this case, proceed to step 3.
• Identify your valve body type by looking at the silver ID sticker on the
back or side of the valve body.
• Select your valve body type using the UP or DOWN buttons.
• Display
Valve Body
255
255, 7-cycle conditioner
263
Performa filter 263, 3-cycle filter
268
Performa conditioner 268, 7-cycle conditioner
273
Performa Cv 273, 3-cycle filter
278
Performa Cv 278, 5-cycle conditioner
293
Magnum Cv filter, 3-cycle filter
298
Magnum Cv conditioner, 7-cycle conditioner
Step 2: Program System Size
This step may have been performed by your system’s OEM manufacturer. In this
case, proceed to step 3.
•
Input system size - resin volume - in cubic feet or liters.
•
Use UP and DOWN buttons to scroll through resin volume choices.
•
Choose the nearest volume to your actual system size.
•
To choose a 3-cycle filter operation - press DOWN until an "F" is displayed.
•
Press SET to accept the system size you’ve selected.
•
If incorrect setting is programmed, see "Resetting the Control" section below.
Step 3: Program Time of Day
•
While "12:00" is blinking, set the correct time of day.
•
Use the UP and DOWN buttons to scroll to the correct time of day.
•
"PM" is indicated, "AM" is not indicated.
•
Press SET to accept the correct time of day and advance to the next
parameter.
Step 4: Set Day of Week
•
Press SET to make the arrow under SU flash.
•
Use the UP and DOWN buttons to advance the arrow until it is under the
correct day of week.
•
Press SET to accept and advance to the next parameter.
Step 5: Set Regen Time
•
2:00 (AM) is the default time of regeneration. To accept this time, press the
DOWN button to move to step 6.
•
To change the regen time, press SET - causing 2:00 to flash.
•
Use the UP and DOWN buttons to advance to the desired regen time.
•
Press SET to accept the time and advance to the next parameter.
NOTE:
Different 742/762 control hardware is necessary to operate the 150S
valve body.
Time & Day
Regen Time & Day
Salt
SU MO TU WE TH FR SA DAYS
Capacity
Hardness
Time & Day
Regen Time & Day
Salt
SU MO TU WE TH FR SA DAYS
Capacity
Hardness
Time & Day
SU MO TU WE TH FR SA DAYS
Capacity
Hardness
Time & Day
Regen Time & Day
Salt
SU MO TU WE TH FR SA DAYS
Capacity
Hardness
Time & Day
Regen Time & Day
Salt
SU MO TU WE TH FR SA DAYS
Capacity
Hardness