36
Initial Start-up Step-By-Step Instructions
Rev B
5. Add water to the regenerant tank (initial fill) (conditioner and FA filters
only).
A. With a bucket or hose, add approximately 4 gallons (15 liters) of
water to the regenerant tank.
If the tank has a salt platform in the bottom of the tank, add water
until the water level is approximately 1 inch (25 mm) above the
platform.
6. Engage the refill cycle to prime the line between the regenerant tank
and the valve (conditioner only).
A. Slowly open the main water supply valve again, to the fully open
position. Be sure not to open too rapidly as that would push the
media out of the media tank.
B. Advance the controller to the Refill (C8) position. From cycle C1
(Backwash), press and hold the SET button. This will display the
current cycle.
While pressing the SET button, press UP to advance to the next
cycle. Continue to advance through each cycle until you have
reached cycle C8 (Refill).
C. With the water supply completely open, when you arrive at cycle
C8 (Refill), the controller will direct water down through the line to
the regenerant tank. Let the water flow through the line until all air
bubbles have been purged from the line.
D. Do not let the water flow down the line to the tank for more than one
to two minutes, or the tank may overfill.
E. Once the air is purged from the line, press the SET button and the UP
button simultaneously to advance to cycle C0 (Treated Water)
position.
NOTE:
We recommend that you do not put regenerant into the tank until after
the control valve has been put into operation. With no regenerant in the tank, it
is much easier to view water flow and motion in the tank.
NOTE:
As you advance through each cycle there will be a slight delay before
you can advance to the next cycle. The hourglass icon will light while the
camshaft is indexing. There may be a pause at cycle C4 (System Pause). This
cycle allows the water/air pressure to equalize on each side of the valve discs
before moving on. The hourglass will not be visible indicating that the system is
paused.
Time & Day
Regen Time & Day
Salt
SU MO TU WE TH FR SA DAYS
C
Capacity
Hardness