background image

Model Number

UM-2100-762

Salt Type 

NaCL

Tank diameter (in)

9

Resin Depth (in)

29.4

Total Bed Depth (in)

29.4

Rated Service Flow (gpm)

10.2

Pressure Drop at Rated Flow Rate

11 psi

Resin Volume (ft

3

)

1

Slow Rinse Flow Rate (gpm)

0.24

Total Rinse Volume per unit of resin volume 

(gal/ft

3

)

40.7

Cross-sectional Area (ft

2

)

0.442

Maximum Flow Rate to 

Drain During Regeneration Cycle

5.2gpm

Maximum published flow rate per unit of 

cation exchange media volume (gpm/ft

3

)

9.9

Slowest rinse flow rate per unit of bed 

cross-sectional area (gpm/ft

2

)

0.544

Resin type (Standard [s] or Fine Mesh [fm]

s

Capacity Correction factor CF

c

Taken from ANSI/NSF 44, Figure 5 or 6)

92.139

Salt Level (lbs)

Capacity (grains)

Salt Efficiency (gr/lb)

3.333

13,800

4150

9.0

28,100

N/A

15.0

32,300

N/A

Summary of Contents for UM-2100-762

Page 1: ...rehouse Inc 1700 E Walnut Ave Fullerton CA 92831 TEL 714 441 2893 FAX 714 441 0525 Manufactured by Models UM 2100 762 UM 2150 762 UM 2200 762 SOFTENERS ARE NOT INTENDED TO BE USED FOR TREATING WATER T...

Page 2: ...3 40 7 Cross sectional Area ft2 0 442 Maximum Flow Rate to Drain During Regeneration Cycle 5 2gpm Maximum published flow rate per unit of cation exchange media volume gpm ft3 9 9 Slowest rinse flow ra...

Page 3: ...26 7 Cross sectional Area ft2 0 545 Maximum Flow Rate to Drain During Regeneration Cycle 5 2gpm Maximum published flow rate per unit of cation exchange media volume gpm ft3 8 4 Slowest rinse flow rate...

Page 4: ...19 7 Cross sectional Area ft2 0 785 Maximum Flow Rate to Drain During Regeneration Cycle 5 2gpm Maximum published flow rate per unit of cation exchange media volume gpm ft3 7 2 Slowest rinse flow rat...

Page 5: ...Conditioners DETERMINING IF YOU HAVE A 742 OR 762 CONTROL 24 GENERAL 700 SERIES INSTRUCTIONS 24 Display Icons 700 Controller Keypad Buttons Regeneration Modes 742 762 Series Initial Power Up Initial S...

Page 6: ...rotate to the HOME in service position Camshaft may take 1 2 minutes to return to home position Err 3 will be displayed until the camshaft returns to home If more than 2 minutes elapses verify that t...

Page 7: ...t setting is programmed see Resetting the Control section below Step 3 Program Time of Day While 12 00 is blinking set the correct time of day Use the UP and DOWN buttons to scroll to the correct time...

Page 8: ...ant amount Press SET to accept the setting and advance to next parameter See page 31 for more complete information on regenerant settings for different system sizes capacities and expected efficiencie...

Page 9: ...n symbol will be displayed After immediate regeneration has begun press REGEN again to initiate a second manual regeneration An X2 symbol will be displayed indicating a second regeneration will follow...

Page 10: ...he control will be reset to an unprogrammed state 6 Go to Initial Set up section of this sheet to reprogram control Further programming or set up instructions can be found in this manual Unprogrammed...

Page 11: ...erson installing this equipment should have Training in the 700 Logix series controllers and water conditioner installation Knowledge of water conditioning and how to determine proper control settings...

Page 12: ...may be used on connections that do not use an O ring seal Do not use pliers or pipe wrenches All plumbing must be completed according to local codes Soldering near the drain line should be done befor...

Page 13: ...rts to set before installing any plastic parts Do not get primer or solvent on O rings nuts or the valve System Regeneration Cycles 5 Cycle Operation 1 Service Downflow Cycle C0 Untreated water is dir...

Page 14: ...s during a portion of the fast rinse cycle Water is directed to the regenerant tank at a controlled rate to create brine for the next regeneration Figure 1 SERVICE BACKWASH BRINE SLOW RINSE FAST RINSE...

Page 15: ...alve Identification Refill Controller Regenerant Tube Connection Injector and cap Valve Discs Outlet Drain Inlet Backwash Injector Screen Camshaft Drain Control Filter Control Module Mount One Piece V...

Page 16: ...eater of ten feet three meters to prevent backup of hot water into system Local drain for discharge as close as possible Water line connections with shutoff or bypass valves Must meet any local and st...

Page 17: ...valve This will cause physical damage to the internal parts as well as the plumbing High temperatures will affect the controller The display may become unreadable but the controller should continue to...

Page 18: ...Operation In Bypass Water Conditioner Water Conditioner WARNING The inlet water must be connected to the inlet port of the valve When replacing non Autotrol valves the inlet and outlet may be reversed...

Page 19: ...additional 10 psi 69 bar of water pressure at the drain connector 4 Where the drain line is elevated but empties into a drain below the level of the control valve form a 7 inch 18 cm loop at the far e...

Page 20: ...and run to drain Do not elevate overflow line higher than overflow fitting Do not tie into drain line of control unit Overflow line must be a direct separate line from overflow fitting to drain sewer...

Page 21: ...raw regenerant from the tank This may also introduce air into the valve causing problems with valve operation Figure 8 Regenerant Connection for Performa Valve An aircheck must be used in the regenera...

Page 22: ...n 12 volt alternating current power supply This requires use of the supplied AC adapter A variety of AC adapters are available for different applications These AC adapters are available from your supp...

Page 23: ...mount connection P N 1256257 is available for the 700 Series controller Valve Camshaft The front end of the camshaft has an indicator cup The cup has slots in the outer periphery and numbers on the in...

Page 24: ...used in filter mode C3 Slow Rinse Cycle not used in filter mode C4 System Pause Repressurization cycle C5 Fast Rinse Cycle 1 C8 Regenerant Refill not used in filter mode Valve Disc Operation Figure 11...

Page 25: ...ctant available a choice can be made among the following methods Sodium or Calcium Hypochlorite Application These materials are satisfactory for use with polystyrene resins synthetic gel zeolite green...

Page 26: ...used directly without dissolving before use 1 Dosage A Two grains approximately 0 1 ounce 3 mL per cubic foot 2 Regenerant tank conditioners A Backwash the conditioner and add the required amount of...

Page 27: ...SERIES INSTRUCTIONS Display Icons 700 Controller Figure 13 GE Infrastructure Milwaukee WI USA Autotrol Brand Model 762 12 V 60 Hz 4W VERSION 1 02 WO 4340000 Ser No 740090052683 3 Model number either...

Page 28: ...d for error codes 10 Colon flashes as part of the time display Indicates normal operation 742 only 11 Locked unlocked indicator In Level I programming this is displayed when the current parameter is l...

Page 29: ...dentifies which history value is currently displayed 25 Parameter P Displayed only in Level II Programming The number displayed by 23 identifies which parameter is currently displayed 26 Cycle C The n...

Page 30: ...ration Modes The 700 Series controllers can be regenerated either automatically or manually During a regeneration the total time remaining of the regeneration will be displayed on the controller The c...

Page 31: ...dvance on cycle An hourglass will display while cam is advancing When cam reaches next cycle C2 will be displayed Repeat SET and UP to advance through each cycle Press and hold SET and UP for 5 second...

Page 32: ...the back or side of the valve body Select your valve body type using the UP and DOWN buttons Display Valve Body 255 255 7 cycle conditioner 263 Performa filter 263 3 cycle filter 268 Performa conditio...

Page 33: ...of week Press SET to accept and advance to the next parameter After steps 1 4 the controller will operate most systems Proceed to step 5 if further adjustments to your system s programming is needed...

Page 34: ...ar override on demand control 0 days is the default for calendar override Days can be adjusted from 5 to 99 days To change press SET to make the 0 flash Use the UP and DOWN buttons to change to the nu...

Page 35: ...e media type and amount used The controller can use 0 to 99 minutes for backwash Press SET again to enter that time Table 1 High Efficiency Exchange Capacity Salt lbs cu ft Exchange Capacity grains cu...

Page 36: ...T to make the setting flags Use the UP and DOWN buttons to scroll to the correct hardness Press SET to accept the entered hardness value The control will return you to the normal operation mode FA fil...

Page 37: ...The draw and refill cycle times cannot be changed in cycle time programming for conditioner valves Draw and refill times are calculated using the draw and refill rates and salt amounts The draw and r...

Page 38: ...u press and hold the SET button the controller will indicate the time remaining in the current cycle 4 Fill the media tank with water A While the controller is in cycle C1 Backwash open the water supp...

Page 39: ...letely open when you arrive at cycle C8 Refill the controller will direct water down through the line to the regenerant tank Let the water flow through the line until all air bubbles have been purged...

Page 40: ...at the water in the regenerant tank is being drawn out of the tank The water level in the tank should recede very slowly C Observe the water being drawn from the regenerant tank for at least three min...

Page 41: ...correctly The initial resin volume should be set to the closest volume of the manganese greensand in the system For example if the system contains two cubic feet of manganese greensand program in 2 0...

Page 42: ...capacity Solution regenerate every 3 days Volume Demand Regeneration Setting To set a 762 demand system for iron removal you must 1 Know your media capacity Generally one cubic foot of magnesium gree...

Page 43: ...English units The 700 Series controller can be programmed to regenerate on specific days of the week If electrical power is not available the camshaft can be rotated counterclockwise by hand if the m...

Page 44: ...day of week Move to desired display UP or DOWN arrows Press and Release Will increment through the displays Enable setting to be changed SET Press and Release Display will flash Change setting UP or D...

Page 45: ...ween regeneration 99 day calendar override P5 Not used 742 only P6 Amount of regenerant used per regeneration or filter backwash time salt setting P7 System capacity P8 Hardness P9 Units of measure P1...

Page 46: ...ons or 0 61 310 70 m3 762 only H4 Water used since last regeneration in gallons m3 0 131 070 gallons or 0 61 310 70 m3 762 only H5 Total water used since reset in 100s 0 999 900 gallons or 0 9 999 m3...

Page 47: ...vance programming or set up instructions can be found in the Dealer Installation and Service Manual P N 1255652 WARNING Resetting the control will delete all information stored in its memory except ti...

Page 48: ...Performa Exploded View 45 Rev B PARTS AND ACCESSORIES Performa Exploded View 2 1 3 4 5 6 7 8 9 10 11 12 13 14 16 17 7 15 18 Warning Do not use the flow control ball with 10A 19 20...

Page 49: ...1001769 3 4 inch NPT Plastic Pipe Adapter Kit 1239760 Blending Valve Kit 900 700 Series Top Plate 1001603 1 inch NPT Plastic Pipe Adapter Kit Drain Line Flow Control External 1001604 3 4 inch BSPT Pl...

Page 50: ...r 1242150 Logix 742 Controller 1000810 Japanese 1242162 Logix 742 F Controller 1000811 North American 1242168 Logix 762 Controller 1000812 Australian 1242170 Logix 762F Controller 1000813 British Elec...

Page 51: ...hourglass should be flashing on the display indicating the motor is running Camshaft is not turning during ERR 3 display Check that motor is connected Verify that motor wire harness is connected to m...

Page 52: ...e correct setting according to instructions b Remove restriction c Clean injector and screen d Replace injector and cap Contact dealer e Remove foreign matter from disc and check disc for closing by p...

Page 53: ...bine should spin freely If not replace meter Contact dealer 13 Run out of conditioned water between regenerations a Improper regeneration b Incorrect regenerant setting c Incorrect hardness or capacit...

Page 54: ...ers have been removed Fouling or damage to the resin caused by iron sulfur bacterial iron silt sand tannins organics bacteria or chlorine voids the warranty on the resin These warranties are in lieu o...

Reviews: