Therma-Stor, LLC (“Therma-Stor”) warrants as 

follows: (i) the Ultra-Aire 100V dehumidifier (“Product”) will be free 
of material defects in workmanship or materials for a period of one 
(1) year (“One-Year Warranty”) following the date of initial purchase 
of such Product by an original customer purchasing from Therma-
Stor or an authorized reseller (“Customer”); and (ii) the Product’s 
condenser, evaporator, and compressor will be free of material 
defects in workmanship or materials for a period of five (5) years 
following the date of initial purchase of such Product by a Customer. 

Limitation of Remedies.

 CUSTOMER’S SOLE AND EXCLUSIVE 

REMEDY UNDER THE ABOVE LIMITED WARRANTY AND THERMA- 
STOR’S ENTIRE LIABILITY THEREUNDER, SHALL BE, AT THE SOLE 
OPTION OF THERMA-STOR, REPLACEMENT OR REPAIR OF SUCH 
PRODUCT OR ITS COMPONENTS (“COMPONENTS”) BY THERMA-
STOR OR THERMA-STOR’S AGENTS ONLY. REFRIGERANT, PIPING, 
SUPPLIES, TRANSPORTATION COSTS, LABOR COSTS INCURRED 
IN REPAIR OR REPLACEMENT OF SUCH COMPONENTS ARE NOT 
INCLUDED. THIS DISCLAIMER AND EXCLUSION SHALL APPLY 
EVEN IF THE EXPRESS WARRANTY AND LIMITED REMEDY SET 
FORTH HEREIN FAILS OF ITS ESSENTIAL PURPOSE. CUSTOMER 
ACKNOWLEDGES THAT NO REPRESENTATIVE OF THERMA-STOR OR 
OF ITS AFFILIATES OR RESELLERS IS AUTHORIZED TO MAKE ANY 
REPRESENTATION OR WARRANTY ON BEHALF OF THERMA-STOR 
OR ANY OF ITS AFFILIATES OR RESELLERS THAT IS NOT IN THIS 
AGREEMENT. Notwithstanding the above, during the term of the 
One-Year Warranty only, Therma-Stor will provide, free of charge to 
Customer, all Components and labor (except costs related to removal 
and installation of Product) required to fulfill its obligations under such 
One-Year Warranty. 

Disclaimer of Warranties. 

EXCEPT FOR ABOVE LIMITED 

WARRANTY, WHICH IS THE SOLE AND EXCLUSIVE WARRANTY 
PROVIDED WITH RESPECT TO THE PRODUCT AND ITS COMPONENTS, 
THERMA-STOR HEREBY DISCLAIMS ALL EXPRESS AND IMPLIED 
WARRANTIES, INCLUDING, WITHOUT LIMITATION, THE IMPLIED 
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A 
PARTICULAR PURPOSE. 

Warranty Limitations.

 The foregoing limited warranty extends only 

to a Customer and shall be null and void upon attempted assignment 
or transfer. A “defect” under the terms of the limited warranty shall 
not include problems resulting from Customer’s or Customer’s 
employees’, agents’, invitees’ or a third party’s misuse, improper 
installation, improper design of any system in which the Product 
is included, abuse, lack of normal care, failure to follow written 
instructions, tampering, improper repair, or freezing, corrosion, acts 
of nature or other causes not arising out of defects in Therma-Stor’s 
workmanship or material. If a Product or Component is replaced 
while under warranty, the applicable limited warranty period shall 
not be extended beyond the original warranty time period. The 
limited warranty does not cover any costs related to changes to a 
Product or Component that may be required by any codes, laws, or 
regulations that may become effective after initial purchase of the 
Product by Customer. 

Customer Responsibilities. 

As a further condition to obtaining 

warranty coverage hereunder, the Customer must send a valid 
warranty claim to Therma-Stor such that Therma-Stor receives 
such claim prior to the end of the applicable warranty period. 
Therma-Stor shall have no obligation hereunder with respect to 
any claim received by Therma-Stor after the expiration of the 
applicable warranty period. As a further condition to obtaining 
warranty coverage hereunder, the Customer must present forms of 
invoices evidencing proof of purchase of a Product. If such invoices 
do not clearly indicate the date of initial purchase by a Customer, 
the applicable Product’s date of manufacture will be used instead 
of the date of initial purchase for the purpose of calculating the 
commencement of the applicable warranty period. Warranty service 
must be performed by Therma-Stor or a servicer authorized by 
Therma-Stor. In order to obtain warranty service, the Customer 
should call Therma-Stor at 1-800-533-7533 and ask for the 
Therma-Stor Products Service Department, which will then arrange 
for applicable warranty service. Warranty service will be performed 
during customary, daytime working hours. If the Product must be 
shipped for service, Customer shall be solely responsible for properly 
packaging the Product, for all freight charges, and for all risk of loss 
associated with shipment. 

Limitation of Liability. 

IN NO EVENT SHALL THERMA-STOR, 

IN CONNECTION WITH THE DESIGN, SALE, INSTALLATION, USE, 
REPAIR, REPLACEMENT OR PERFORMANCE OF ANY PRODUCT, 
COMPONENT, PART THEREOF OR WRITTEN MATERIAL PROVIDED 
THEREWITH, BE LIABLE, TO THE EXTENT ALLOWED UNDER 
APPLICABLE LAW, UNDER ANY LEGAL THEORY FOR ANY SPECIAL, 
DIRECT, INDIRECT, COLLATERAL OR CONSEQUENTIAL DAMAGES 
OF ANY KIND. NOTWITHSTANDING THE ABOVE LIMITATIONS AND 
WARRANTIES, THE SOLE AND EXCLUSIVE LIABILITY OF THERMA-
STOR, REGARDLESS OF THE NATURE OR THEORY OF THE CLAIM, 
SHALL UNDER NO CIRCUMSTANCES EXCEED THE PURCHASE PRICE 
OF THE PRODUCT, COMPONENT OR PART UPON WHICH THE CLAIM 
IS PREMISED. 

Applicable Law and Venue.

 ANY ARBITRATION, ENFORCEMENT 

OF AN ARBITRATION OR LITIGATION RELATED TO THE PRODUCT 
WILL BE BROUGHT EXCLUSIVELY IN DANE COUNTY, WISCONSIN, 
AND CUSTOMER CONSENTS TO THE JURISDICTION OF THE 
FEDERAL AND STATE COURTS LOCATED THEREIN, SUBMITS TO 
THE JURISDICTION THEREOF AND WAIVES THE RIGHT TO CHANGE 
VENUE. CUSTOMER FURTHER CONSENTS TO THE EXERCISE OF 
PERSONAL JURISDICTION BY ANY SUCH COURT WITH RESPECT TO 
ANY SUCH PROCEEDING. 

Miscellaneous.

 If any term or condition of this Limited Warranty 

is found by a court of competent jurisdiction to be invalid, illegal or 
otherwise unenforceable, the same shall not affect the other terms 
or conditions hereof or thereof or the whole of this Limited Warranty. 
Any delay or failure by Therma-Stor to exercise any right or remedy 
will not constitute a waiver of Therma-Stor to thereafter enforce 
such rights.

Summary of Contents for 100V

Page 1: ...resh outdoor air may be ducted to the unit via a six inch round duct This provides fresh air to dilute pollutants and maintain high oxygen content in the air The amount of fresh air ventilation can be regulated by a variety of dampers and controls Air Filtration The UA 100V includes air filtration to improve indoor air quality A MERV 11 media filter is standard An optional MERV 14 deep pleated 95 ...

Page 2: ...NEL INACCESSIBLE Avoid directing the discharge air at people or over the water in pool areas If used near a pool or spa be certain there is NO chance the unit could fall into the water splashed and that it is plugged into a GFCI GROUND FAULT CIRCUIT INTERRUPT OUTLET DO NOT use the device as a bench or table DO NOT place the device directly on structural members A drain pan MUST be placed under the...

Page 3: ... building supply plumbing and hardware stores It will slide tightly inside the end of the drain hose If more than one length of pipe is required they can be joined with a short piece cut from the end of the drain hose An optional condensate pump may be installed if a lift is required to dispose of the condensate The condensate pump kit can be ordered direct from the factory See item 27 on page 21 ...

Page 4: ... calling 1 800 533 7533 for recommendations regarding the use of higher flows with your specific application The outside air duct should be connected to the 6 round collar on top of the unit The 6 round collar includes a manual damper Adjust the manual damper to provide the desired amount of fresh air for ventilation The amount of fresh air should be based on the size and occupancy of the residenc...

Page 5: ...By ducting this way the air inside the structure will circulate through the Ultra Aire to be filtered and dehumidified Connect a duct from outside to the 6 collar of the Ultra Aire if you wish to provide fresh make up air 3 5 Quiet Installation A length of 10 feet or more of acoustical flex ducting on the outlet of the Ultra Aire will reduce air noise from the blower A length of flexible ducting o...

Page 6: ...dity Range Accuracy 10 95 RH 5 Auxillary Relay Capacity 5 Amps 24VAC Temp Range Accuracy 30 90 F 2 Size 4 95 L x 1 06 W x 4 19 H Major Operations n Digital control of Relative Humidity Digital Set Point n Fan Filter Operation n Programmable Ventilation Timer n Large easy to read backlit LCD display n Easy interaction with air handler fan Interlock Lockout n High Temperature Cut Out n Dryout Cycle ...

Page 7: ... efficiency pleated paper filter Do not attempt to clean the high efficiency pleated paper filter It should be replaced when it becomes restrictive See Figure 7 7 Service CAUTION Servicing the Ultra Aire with its high pressure refrigerant system and high voltage circuitry presents a health hazard which could result in death serious bodily injury and or property damage Only qualified service people...

Page 8: ...n by reversing the above procedure 7 6 Compressor Capacitor Replacement This compressor is equipped with a two terminal external overload and a run capacitor but no start capacitor or relay See Figure 4 CAUTION ELECTRICAL SHOCK HAZARD Electrical power must be present to perform some tests These tests should be performed by a qualified service person 7 6A Checking Compressor Motor Circuits Perform ...

Page 9: ... suction line filter driers will probably clean up the system If sludge is evident in the discharge line it will likely be found in the suction line This indicates the compressor burned out will running Sludge and acid have been pumped throughout the system Several changes of the liquid and suction filter driers will probably be necessary to cleanse the system 5 Correct the system fault that cause...

Page 10: ...entilation timer is not activated to prevent over ventilating the structure when the unit is dehumidifying or recirculating the indoor air The electric ventilation timer operates on 24 Vac from the control circuit DO NOT connect high voltage to the damper motor or damage to the motor may result DO NOT force the blade of the damper by hand or damage to the damper motor may result The damper opens i...

Page 11: ...ULTRA AIRE 100V PICTORIAL ELECTRICAL DIAGRAM N O WHT WHT 11 Ultra Aire 100V Installer s Owner s Manual ...

Page 12: ...ly 9 4029168 1 Compressor 10 4029169 1 Compressor Overload 11 4028226 1 Condenser Coil 12 4022445 1 Cord Wire Harness 13 4029510 1 Filter Drier 14 4021626 1 Hose Drain Pan 56 ID x 8 15 4022484 1 Relay SPST 24 Vac 30A 16 4020924 1 Relay SPDT 24 Vac 15A 17 4033032 05 1 Run Capacitor 45 MFD 370V 18 4025741 1 Thermostat Defrost 4021648 1 Defrost Control Mounting Clip 19 4022487 1 Transformer 120 24 Va...

Page 13: ... 90 95 4022220 1 Condensate Pump Kit 4023672 1 Damper Duct 6 Diameter Electrically Actuated not shown 4023647 1 Damper Check 8 Diameter not shown 4021475 1 MERV 11 Filter 16 x 20 x 2 4022489 1 MERV 14 Filter 16 x 20 x 4 4022220 1 Pump Kit 4023484 1 Attic Insulation Kit 4023672 1 6 Motorized Damper 4020656 1 6 Inlet Exhaust Hood 4023647 1 8 Gravity Damper 4020646 1 8 Butterfly Damper ...

Page 14: ...costs related to changes to a Product or Component that may be required by any codes laws or regulations that may become effective after initial purchase of the Product by Customer Customer Responsibilities As a further condition to obtaining warranty coverage hereunder the Customer must send a valid warranty claim to Therma Stor such that Therma Stor receives such claim prior to the end of the ap...

Page 15: ...hermastor com Information in this document is subject to change without notice No part of this document may be reproduced or transmitted in any form or by any means electronic or mechanical for any purpose without the express written permission of Therma Stor LLC 2008 Therma Stor LLC All rights reserved ...

Reviews: