background image

crawlspace. Duct the other side of the tee to the air return of the 
existing HVAC system. If the existing HVAC system has a central 
return, duct the other side of the tee to the air supply of the existing 
HVAC system. Connect a duct from outside to the 6" collar of the 
Ultra-Aire if you wish to provide fresh make-up air. 

3.4E Installation in an Attic with an Existing Forced 

Air HVAC System
ALWAYS install a catch pan for condensate under the 

Ultra-Aire in an attic or condensate may drip down on 

the ceiling of the living space below. 

Locate a separate return for the Ultra-Aire in a central area of the 
structure. Duct the supply of the Ultra-Aire to the air supply of the 
existing HVAC system. If the existing HVAC system has a central 
return, duct the supply of the Ultra-Aire to the air supply of the 
existing HVAC system. Connect a duct from outside to the 6" collar 
of the Ultra-Aire if you wish to provide fresh make-up air.

3.4F Installation in a Structure with   Two Forced Air 

HVAC Systems

Attach the Ultra-Aire return to to a independent return from the 
upper level. Attach the Ultra-Aire supply to the supply of the 
basement HVAC system. This will promote circulation of air through 
the whole structure from the upper level to the lower level through 
the Ultra-Aire . If the Ultra-Aire is not connected to both HVAC 
systems, it will not control the humidity and ventilation of the entire 
structure. Connect a duct from outside to the 6" collar of the Ultra-
Aire if you wish to provide fresh make-up air.

3.4G Installation in a Structure with   No Existing 

Forced Air HVAC Systems

When installing the Ultra-Aire in a structure that does not have a 
forced air HVAC system, a single return for the Ultra-Aire should 
be installed in central open area of the structure. 

DO NOT

 locate 

the return in a bathroom or a kitchen. The supply of the Ultra-
Aire should be located in the remote areas of the structure (such 
as bedrooms, den, etc.). By ducting this way the air inside the 
structure will circulate through the Ultra-Aire to be filtered and 
dehumidified. Connect a duct from outside to the 6" collar of the 
Ultra-Aire if you wish to provide fresh make-up air.

3.5 Quiet Installation

A length of 10 feet or more of acoustical flex ducting on the outlet of 
the Ultra-Aire will reduce air noise from the blower. A length of flexible 
ducting on all Ultra-Aire duct connections is recommended to reduce 
noise and vibration transmitted to rigid ductwork in the structure.

4. Controls

All control panels should be mounted in a central area of the 4. 
Controls

The Ultra-Aire can be equipped with various accessories to 
enhance its operation. A remote control must be used with the 
Ultra-Aire. ThermaStor offers the DEH 3000 proprietary controller. 
The DEH 3000 allows homeowners the ability to monitor and 
control relative humidity levels in their home. This control is also 
offered witha remote sensing option.

WARNING: 

DO NOT 

allow the yellow lead from 

the unit to contact the red lead or the white lead from 
the unit or damage to the transformers will result. 

The UA dehumidifier is controlled using five color-coded wires.

Green (or brown)

 = Fan control 

Blue 

= Dehumidification (fan and compressor) control 

Red

 = 24volt AC power transformer neutral side (common with white)

White 

= 24volt AC power transformer neutral side (common with red)

Yellow

 = transformer high side  

Between the red/white lead and the yellow leads is a 40VA trans-
former. This low voltage power source powers the relay coils which 
control the fan and compressors. This 24VAC transformer can also 
be used to power HVAC assessories external to the dehumidifier.
•  To turn the dehumidifier on make contact between yellow and 

blue wires.

•  To turn the fan on make contact between yellow and green(or 

brown) wires.

•  To power an HVAC accessory, connect the accessory to the 

white (or red) wire and the yellow wire.

FOR HVAC INSTALLER ONLY

5

Ultra-Aire 100V Installer’s & Owner’s Manual

Ultra-Aire

Dehumidifier

RED

YELLOW

BLUE

GREEN or BROWN

WHIT

E

Internal Connections

OPTIONAL 

DAMPER

24 

VA

C

DMP   COMP   FAN

(P/N 4028539; with remote: P/N 4028407)

Summary of Contents for 100V

Page 1: ...resh outdoor air may be ducted to the unit via a six inch round duct This provides fresh air to dilute pollutants and maintain high oxygen content in the air The amount of fresh air ventilation can be regulated by a variety of dampers and controls Air Filtration The UA 100V includes air filtration to improve indoor air quality A MERV 11 media filter is standard An optional MERV 14 deep pleated 95 ...

Page 2: ...NEL INACCESSIBLE Avoid directing the discharge air at people or over the water in pool areas If used near a pool or spa be certain there is NO chance the unit could fall into the water splashed and that it is plugged into a GFCI GROUND FAULT CIRCUIT INTERRUPT OUTLET DO NOT use the device as a bench or table DO NOT place the device directly on structural members A drain pan MUST be placed under the...

Page 3: ... building supply plumbing and hardware stores It will slide tightly inside the end of the drain hose If more than one length of pipe is required they can be joined with a short piece cut from the end of the drain hose An optional condensate pump may be installed if a lift is required to dispose of the condensate The condensate pump kit can be ordered direct from the factory See item 27 on page 21 ...

Page 4: ... calling 1 800 533 7533 for recommendations regarding the use of higher flows with your specific application The outside air duct should be connected to the 6 round collar on top of the unit The 6 round collar includes a manual damper Adjust the manual damper to provide the desired amount of fresh air for ventilation The amount of fresh air should be based on the size and occupancy of the residenc...

Page 5: ...By ducting this way the air inside the structure will circulate through the Ultra Aire to be filtered and dehumidified Connect a duct from outside to the 6 collar of the Ultra Aire if you wish to provide fresh make up air 3 5 Quiet Installation A length of 10 feet or more of acoustical flex ducting on the outlet of the Ultra Aire will reduce air noise from the blower A length of flexible ducting o...

Page 6: ...dity Range Accuracy 10 95 RH 5 Auxillary Relay Capacity 5 Amps 24VAC Temp Range Accuracy 30 90 F 2 Size 4 95 L x 1 06 W x 4 19 H Major Operations n Digital control of Relative Humidity Digital Set Point n Fan Filter Operation n Programmable Ventilation Timer n Large easy to read backlit LCD display n Easy interaction with air handler fan Interlock Lockout n High Temperature Cut Out n Dryout Cycle ...

Page 7: ... efficiency pleated paper filter Do not attempt to clean the high efficiency pleated paper filter It should be replaced when it becomes restrictive See Figure 7 7 Service CAUTION Servicing the Ultra Aire with its high pressure refrigerant system and high voltage circuitry presents a health hazard which could result in death serious bodily injury and or property damage Only qualified service people...

Page 8: ...n by reversing the above procedure 7 6 Compressor Capacitor Replacement This compressor is equipped with a two terminal external overload and a run capacitor but no start capacitor or relay See Figure 4 CAUTION ELECTRICAL SHOCK HAZARD Electrical power must be present to perform some tests These tests should be performed by a qualified service person 7 6A Checking Compressor Motor Circuits Perform ...

Page 9: ... suction line filter driers will probably clean up the system If sludge is evident in the discharge line it will likely be found in the suction line This indicates the compressor burned out will running Sludge and acid have been pumped throughout the system Several changes of the liquid and suction filter driers will probably be necessary to cleanse the system 5 Correct the system fault that cause...

Page 10: ...entilation timer is not activated to prevent over ventilating the structure when the unit is dehumidifying or recirculating the indoor air The electric ventilation timer operates on 24 Vac from the control circuit DO NOT connect high voltage to the damper motor or damage to the motor may result DO NOT force the blade of the damper by hand or damage to the damper motor may result The damper opens i...

Page 11: ...ULTRA AIRE 100V PICTORIAL ELECTRICAL DIAGRAM N O WHT WHT 11 Ultra Aire 100V Installer s Owner s Manual ...

Page 12: ...ly 9 4029168 1 Compressor 10 4029169 1 Compressor Overload 11 4028226 1 Condenser Coil 12 4022445 1 Cord Wire Harness 13 4029510 1 Filter Drier 14 4021626 1 Hose Drain Pan 56 ID x 8 15 4022484 1 Relay SPST 24 Vac 30A 16 4020924 1 Relay SPDT 24 Vac 15A 17 4033032 05 1 Run Capacitor 45 MFD 370V 18 4025741 1 Thermostat Defrost 4021648 1 Defrost Control Mounting Clip 19 4022487 1 Transformer 120 24 Va...

Page 13: ... 90 95 4022220 1 Condensate Pump Kit 4023672 1 Damper Duct 6 Diameter Electrically Actuated not shown 4023647 1 Damper Check 8 Diameter not shown 4021475 1 MERV 11 Filter 16 x 20 x 2 4022489 1 MERV 14 Filter 16 x 20 x 4 4022220 1 Pump Kit 4023484 1 Attic Insulation Kit 4023672 1 6 Motorized Damper 4020656 1 6 Inlet Exhaust Hood 4023647 1 8 Gravity Damper 4020646 1 8 Butterfly Damper ...

Page 14: ...costs related to changes to a Product or Component that may be required by any codes laws or regulations that may become effective after initial purchase of the Product by Customer Customer Responsibilities As a further condition to obtaining warranty coverage hereunder the Customer must send a valid warranty claim to Therma Stor such that Therma Stor receives such claim prior to the end of the ap...

Page 15: ...hermastor com Information in this document is subject to change without notice No part of this document may be reproduced or transmitted in any form or by any means electronic or mechanical for any purpose without the express written permission of Therma Stor LLC 2008 Therma Stor LLC All rights reserved ...

Reviews: