8.2  Comfort level 

The 

Soft

 and 

Firm

 buttons allow carers to adjust pressures within a safe pre-set range 

to provide patients with enhanced comfort or support whilst maintaining a very good 

level of protection and therapy. Qualified clinical advice must always be taken before 

adjusting mattress pressures. 

The required pressure is selected using the 

Soft 

and 

Firm

 buttons to move the pressure 

by one step at a time.  

When pressing the 

Firm

 button, the output pressure will increase to provide a higher 

pressure output and thus increased support.  

When pressing the 

Soft 

button, the output pressure will be decreased to provider a 

lower pressure output and thus increased comfort. 

To check if the pressure is adequately supporting the patient, slide one hand between 

the air mattress and bed frame to feel under the patient’s bottom. You should be able to 

slide the hand in-between and an acceptable range is approximately 25 t

o 40 mm (1” to 

1-

1/2”

) to ensure the patient Is not bottoming out.

8.3  Auto-detection 

Simultaneously pressing the 

Soft

 and 

Firm

 buttons on the control panel will 

activate 

Auto-Detection

. Once activated the indicator will flash and the 

system will start detecting and will set the internal pressure appropriately. 

The indicator light will flash until the pat

ient’s weight and 

position has been 

detected then the light will extinguish. 

Auto-Detection

 sets the internal 

pressure for the patient so there is no requirement to input 

the patient’s 

weight, the internal pressure setting will vary slightly depending 

on BMI. 

For example if you had two people weighting 65kg one tall and thin the 

other shorter and thicker set, the first patient may auto-detect to 50kg whilst 

the second to 75kg, this is due the difference in their BMI. 

The 

Auto-Detection

 will repeat every 2 hours to allow the system to adjust 

the 

pressure according to the patient’s position.  

 

To turn off the 

Auto-Detection

 simply press the 

Soft

 and 

Firm

 buttons 

again simultaneously. 

8.4  Control panel lockout 

If the control panel is not used for a period of 30 seconds it will lock out and inhibit the 

use of the functions. Additionally, if you wish to lock out the control panel press the 

Lock 

Out

 button and all functions will be locked. This is to prevent the system being altered 

accidently.  

In order to unlock the control panel, simply press and hold the 

Lock Out

 button for 3 

seconds, the control panel will now be active for use. 

+

Summary of Contents for UPRA3678D-2

Page 1: ...Heritage II Digital Dynamic Mattress Replacement System UPRA3678D 2 User Manual Issue 4 16 08 18...

Page 2: ...Page 2 of 29 Issue 4 16 08 18...

Page 3: ...12 8 2 Comfort level 13 8 3 Auto detection 13 8 4 Control panel lockout 13 8 5 Function mode switch 14 8 5 1 Alternate 14 8 5 2 Static 14 8 6 Auto Firm 14 8 7 Alternate cycle time selection 14 8 8 Al...

Page 4: ...Page 4 of 29 Issue 4 16 08 18 15 2 Fuse replacement 21 15 3 Air filter replacement 21 16 EMC Information 22...

Page 5: ...tone 2 1 Contraindications The mattress is not intended to be used by anyone under 12 years of age The mattress is not suitable for use on patients with unstable fractures 3 About the Product The Heri...

Page 6: ...xings Air Pipe Connector 3 x Static Head Cells 11 x Standard Cells Removable Cover 4 x Smaller Lower Legs Cells TPU 1 x Standard Cell Knitted Cell Retention Bands FOOT END HEAD END Air Pipe Connection...

Page 7: ...hat requires correct procedures or practises in order to prevent personal injury BF symbol indicates this product is according to degree of protection against electric shock for type BF equipment The...

Page 8: ...power cable e g by kinking shearing or other mechanical damages The power cable for this product must be unplugged from the mains power outlet socket and suitably stowed before moving cleaning or mai...

Page 9: ...p Classification Class II Type BF Warranty 2 years Operation environment 50C to 400C 15 RH 93 RH no condensation Storage environment 25 70 93 RH no condensation Environment pressure 70 kPa 101 3 kPa W...

Page 10: ...foot end as viewed from the foot of the bed There are security straps fitted to the base cover of the mattress which should be fastened loosely to convenient points on the bedframe patient surface Ca...

Page 11: ...or to the power unit and then ensure that the air tubes are free from any kind of obstruction and are not kinked Plug the power cable into a suitable electrical socket and switch ON using mains power...

Page 12: ...mfort Control Buttons 7 Operate Standby Button Indicators 3 Comfort Setting Indicators 8 Cycle Time Selection Button Alternate 4 Control Panel Lockout Button Indicator 9 Cycle Time Display 5 Function...

Page 13: ...Auto Detection Once activated the indicator will flash and the system will start detecting and will set the internal pressure appropriately The indicator light will flash until the patient s weight an...

Page 14: ...irm button In this mode all cells inflate to a single pressure setting to provide a firm and stable surface for nursing procedures or for patient ingress egress The system will automatically return to...

Page 15: ...sures in the mattress will now equalise but maintain a degree of comfort This will maintain the cells in their present state for approximately 48 hours It is important to restore the Heritage II Digit...

Page 16: ...ystem to be professionally serviced The Annual Service indicator will illuminate after 365 days of use and the indicator light can only be extinguished by a professional service technician once the re...

Page 17: ...connected to the mains power supply and that the mains switch is turned ON Check power unit for any blown fuses Low Pressure indicator is flashing and sounding Check to ensure that the CPR tag is sec...

Page 18: ...s resting against a solid surface Service indicator remains illuminated Indicates that system is scheduled for an annual service Please contact Ultimate Healthcare or your local dealer to arrange If t...

Page 19: ...disinfecting ensure that only a damp cloth is used Caution After cleaning dry the mattress out of direct exposure to sunlight Caution Using inappropriate detergents or disinfectants and not observing...

Page 20: ...e dried or air dried They may be tumble dried on a low heat for up to 90 minutes Drying temperature must not exceed 400C The mattress cover and mattress must be dry prior to refitting Caution Exceedin...

Page 21: ...d plug if there are abrasions or excessive wears 2 Check mattress cover for signs of wear or damage Ensure mattress cover and tubes are stubbed together correctly 3 Check the air hoses for any kink or...

Page 22: ...RF emissions CISPR 11 Group 1 The GD311 401 uses RF energy only for its internal function Therefore its RF emissions are very low and are not likely to cause any interference in nearby electronic equi...

Page 23: ...e s 2kV line s to earth 1kV differential mode Not applicable Mains power quality should be that of a typical commercial or hospital environment Voltage Dips short 5 UT 95 dip in 5 UT 95 dip in Mains p...

Page 24: ...fixed RF transmitters as determined by an electromagnetic site survey a should be less than the compliance level in each frequency range b Interference may occur in the vicinity of equipment marked w...

Page 25: ...r W Separation distance according to frequency of transmitter m 150 kHz to 80 MHz d 1 2 P 80 MHz to 800 MHz d 1 2 P 800 MHz to 2 5 GHz d 2 3 P 0 0 1 0 1 2 0 1 2 0 2 3 0 1 0 38 0 3 8 0 7 3 1 1 2 1 2 2...

Page 26: ...Page 26 of 29 Issue 4 16 08 18...

Page 27: ...Page 27 of 29 Issue 4 16 08 18...

Page 28: ...Page 28 of 29 Issue 4 16 08 18...

Page 29: ...sue 4 16 08 18 Ultimate Healthcare Ltd Calmore Industrial Estate Nutwood Way Totton Southampton Hampshire SO40 3WW Tel 0333 321 8996 Fax 023 8066 2388 Email info ultimatehealthcare co uk www ultimateh...

Reviews: