Electrical system
The engine is standard delivered with one ECU.
However, we offer a completely redundant, dual channel ECU combination. Both systems are
described below.
1. Single ECU & Ignition
1.
Connect to ECU
2.
PC Connector for programming by ULPower
3.
Ground for cable shielding
4.
White/blue: RPM pulse (2 pulses/rev. 0-12V)(Pin No. 9)
White: To optional Fuel Pump Relay(Pin No. 25)
White/green: Fuel consumption (Pin No.24)
White/red: Check light (Pin No. 27)
5.
Battery (+ = Pin No. 23) Battery (- = Pin No. 1)Connect to dashboard switches
6.
Ground for each ignition coil (connect to switch)
! The standard length of the wiring loom is 500 mm. This means that, if you want to install the ECU
on the firewall, the maximum distance between back plate engine and firewall is 400 mm.
Optionally a longer wiring loom is available.