ENKOFORM VMK
Construcción
34
ENKOFORM VMK
4.4.2
Correction of errors when placing the
Board
The position of the WALER MK-120 inside a PANEL
can change from its theoretical position (centralized
with regard to the BOARD). This is known as
assembling interval or tolerance.
If the gap is bigger than 150 mm, the PANEL
CONNECTOR will not be able to close it.
4.4.3
Correction of errors when assembling
walers in panels.
It may happen that PANELS have an assembling error
in the position of MK-120 WALERS. So, when 2 of
these PANELS were placed next to each other, MK-
120 WALERS would not be in the same height, and
there would be problems to join PANELS with each
other.
The gap between the width of the PANEL
CONNECTOR MK and the hollow of the WALER MK-
120 is 1.1 cm. That is the maximum possible error in
the distance between two walers.
The PANEL CONNECTOR MK is designed in such a
way that it will work without any problem within this
range.
Allowed error range of the PANEL CONNECTOR.
11
11
11
11
11
It is suggested that PANELS should be
assembled on a flat surface, on a pattern tool.
The assembling errors can be reduced
considerably if PANELS are assembled in
prepared installations, with appropriate tables
or patterns.
The PANEL CONNECTOR MK guarantees
that PANELS can be assembled when
the gap between the WALERS is
between 0 and 150 mm.