background image

5

Figure 8

Figure 9

SAFETY WARNINGS

W A R N IN G !  It is im perative that the w ater heater tank be filled w ith w ater
before operating the w ater heater.  O peration of the w ater heater w ithout
w ater in th e tank m ay result in d am age to th e tank a nd/or c ontrols.  This
type of dam age is not covered by the lim ited w arranty.

W A R N IN G ! H ydrogen gas m ay result if you have not used this heater for
tw o w eeks or m ore. H Y D R O G E N  G A S  IS  EX TR E M E LY  FLA M M A B LE . To
reduce the risk of injury under these conditions, open the hot w ater faucet
for several m inutes at the kitchen  sink before you use any electrical
appliance connected to the hot w ater system . If hydrogen is present, you
probably w ill hear an unusual sound such as air e sc aping through the
pipe  as  the  w ater  begins  to  flow .

H ydrogen gas m ay be present even after w ater has been drained from  the
tank. O pen faucet at sink and allow  system  to vent for several m inutes (5-
10 m inutes).

D o not sm oke  o r have any open flam e near the open faucet. D o not
attem pt to light pilot or m ain burner. O n D S I m odels, be sure the sw itch
is “O FF ”.

S hould overheating occur, or the gas supply fail to shut off, shut off the
m anual gas valve to the appliance before shutting off the electrical supply.

D o no t use this app lianc e if a ny pa rt has bee n sub m erged  und er w ater.
Im m ediately call a qualified service technician to insp ec t the appliance
and to replace any part of the control system  and any gas control that has
bee n sub m erged  und er w ater.

D o not alter the operation of your w ater heater  n o r change the
design/construction of your w ater heater. A ccessories are being m arketed
for R V  products  w hich w e do not re com m end. For your safety, only
factory autho rized pa rts are to be us ed on  your w ater heater.

P eriodically inspect the vent fo r obstructions or presence of soot. S oot is
form ed w henever com bustion is incom plete. This is your visual w arning
that the w ater heater is operating in an unsafe m anner. If soot is present,
im m ediately shu t the w ater heater dow n and  contact yo u r  d e aler or a
qualified service person.

W hen considering add-on room s, porch or patio, attention m ust be given
to the venting of your w ater heater. For your safety, do not term inate the
vent on your w ater heater inside add-o n  r o o m s, screen porch or onto
patios. D oing s o w ill result in products of com bustion being vented into
the room s or occupied areas.

N ever operate the heater if you sm ell gas. D o not assum e that the sm ell
of gas in your R V  is norm al. A ny tim e y ou d etect th e o dor o f g as, it is to
be considered life threatening and corrected im m ediately. E xtinguish any
open flam es  inc luding cigarettes and evacuate all persons from  the
vehicle. Shut off gas supply at LP gas bottle. (S ee S afety notice on front
cover of this m anual.)

N O T E : A lw ays open both the cold and hot w ater faucets w hen filling
veh icle w ater tank  to allow  air po ckets to be forced  ou t of the w ater heater.
W hen water flow s from  the heater faucets, close both faucets.

W A R N IN G ! D o not store or use com bustible m aterials or liquids near or
adjacent to this heater. The appliance shall not be  installed in any location
w here flam m able liquids or vapors are likely to be present.

B e sure the w ater heater pilot and all ignition system s are “O FF” during
any type of refueling and w hile vehicle is in m otion or being tow ed.

Th e therm ostat on you r w ater hea ter is no t adjustable. It is a tem perature
sensing lim it designed to m aintain a w ater tem perature of 130

/

F (54

/

C ).

W ater tem peratures over 130

/

F (54

/

C ) can cause severe burns ins ta n tly

o r   d e a th  fro m   sc ald s;  th ere fo re ,  be  c are fu l  w h e n  us in g  ho t  w a te r .
C hildren, disabled and elderly are at highest risk of being scalded. A lw ays
feel w ater before bathing or showering.

THERMOSTAT AND MANUAL RESET

S W 4D   (S ee Figure 8)

The m odel w ater heaters listed above are equipped w ith a high tem perature lim it
as a cut-off device. Tem perature above 180

/

F w ill cause m anual reset button to

trip shutting dow n m ain burner.

To activate burner, the w ater tem perature m ust be below  110

/

F, push reset button

to re-activate burner.

ANODE PROTECTION

The tank in this w ater heater is protected by a m agnesium  or alum inum  anode to
prolong the life of the tank by absorbing the corrosive action of hot w ater. U nder
norm al use, the anode rod w ill deteriorate a nd b ecause of this, w e recom m end it
be replaced yearly. N O TE : W ater w ith hig h  le v e ls  of iron and/or sulfate w ill
increase the rate of deterioration; therefore, m ore frequent replacem ent m ay be
required.  If anode rod is m ostly eaten aw ay , replace it w ith a new  one.  (S ee
Figure 9)

O perating the w ater heater w ithout proper anode protection w ill decrease tank life
and w ill void your w arranty on the tank. N O TE : Tank  is drained by rem oving
anode rod (S ee “D rain and S torage” instructions).

To extend anode life, drain w ater from  tank w henever R V  is not being used. A void
any extended  tim e of non-use w ith w ater in tank.

A lso, refer to section on w interizing.

W A R N IN G ! D o not rep lac e the anode rod w ith any non-S uburban
accessory part, such as an “add-on” electric heating elem ent. Item s such
as these are not approved to be installed in Suburban pro ducts. They
could create an unsafe condition and w ill also void all w arranties.

PRESSURE RELIEF VALVE

The tem perature and pressure relief va lve is designed to open if the tem perature
of the w ater w ithin the heater reaches 210°F, or if the w ater pressure in the heater
reaches 150 pounds. R ecreational vehicle w ater system s are closed system s and
during the w ater heating cycle the pressure build-up in the w ater system  w ill reach
150 pounds. W hen this pressure is reached, the pressure  relief valve w ill open
and w ater w ill drip from  th e valve. This d ripping w ill continue until the pressure is
reduced to below  150 pounds, and the valve closes. This condition is norm al and
does not indicate a defective relief valve.

W A R N IN G !  D o  not  place  a  valve  b etw een  the  relief  v alve  a nd  the  tank.  D o
not plug the relief valve under any circum stances.

WATER WEEPING OR DRIPPING FROM PRESSURE

 RELIEF VALVE

Y ou m ay experience w ater w eeping or dripping from  your w ater heater’s P ressure
and Tem perature (P  & T) R elief V alve w hen your w ater heater is operating. W ater
w eeping or dripping from  the P  &  T V alve does not alw ays m ean the P  &  T V alve
is defective. As w ater is heated, it expands. The w ater sy stem  in a recreational
vehicle is a closed system  and does n ot allow  for the expansion of heated w ater.
W hen  the  pressure  of  the  w a ter  system   exceeds  the  relieving  point  of  the  P   &   T
V alve, the valve w ill relieve the excess pressure.

O ne w ay to reduce the frequency of this occurrence is to m aintain an air pocket
at the top of the w ater heater tank. This air pocket w ill form  in the tank by design.
H ow ever, it w ill be reduced over tim e by the everyday use of yo ur w ater heater.

To replenish this air pocket:

1.

Turn off w ater heater.

2.

Turn off cold water supply line.

3.

O pen  a  faucet  in  the  R V .

4.

P ull out on the handle of the P ressure R elief (P  & T) Valve and allow  w ater

to flow  from  the valve until it stops.

5.

R elease handle on P &  T V alve - it should snap closed.

6.

C lose faucet and turn on cold water supply; as the tank fills, the air pocket

w ill develop.

6

R epeat this procedure as often as needed to reduce the frequency of the w eeping
of the P  &  T V alve. If the w eeping persists after follow ing this procedure, you m ay
elect to install an expansion or accum ulator tank in the cold w ater line betw een the
tank and check valve to relieve the  press ure caused by therm al expansion.
C ontact your local dealer for assistance.

DRAINING AND STORAGE INSTRUCTIONS

If R V  is to be stored du ring  w inter m on ths , the  w ater he ater m us t be  d ra ine d  to
prevent dam age from  freezing.

1.

S hut off gas supply to w ater heater.

2.

Turn  off  pressure  pum p  on  w ater  system .

3.

O pen both hot and cold w ater faucets.

4.

R em ove anode  rod from  tank.

5.

Follow   R V   m anufacturer’s  instructions  for  draining  entire  w ater  system .

N O TE : B e certain to refill w ater heater w ith water and rem ove all air from  tank and
lines before re-lighting.

ODOR FROM HOT WATER SYSTEM

O dor from  the hot w ater system  is not a  service problem  and m any w ater supplies
c o ntain sufficien t am ou nts of su lph ur to prod uc e an odo r. The  od or is sim ila r to
rotten eggs and is often referre d to as "sulp h ur w ater". It is not harm ful - only
unpleasant to sm ell. Sulphur w ater can be caused by a chem ical action or by
bacteria. The solution to elim inate is chlorination of the w ater system . Add about
six (6) ounces of chlorinated com m on household liquid bleach to each 10 gallons
in the w ater tank. Then run the chlorinated w ater throughout the system , opening
each faucet one at a tim e until you sm ell the chlorine. Let the R V  sit for a few  days
and the chlorine should take care of the problem . Then you w ill need to take care
of the chlorine. R em ove the chlorine by flu shing th e system  w ith fresh w ater. This

m ay take several a ttem pts. You m ay consider adding a filtering system  that
rem oves  c h lorine and prevents sulphur w ater. If the sulphur or rotten egg sm ell
continues, flush the system  once again as described above and replace anode rod
as necessary.

REMOVING WATER HEATER

1.

S hut off gas supply and disconnect gas supply line from  w ater heater.

2.

S hut off w ater supply. D rain water from  tank follow ing instructions under

“D raining and S torage”.

3.

D isconnect hot and cold w ater lines from  w ater heater.

4.

R em ove screw s or nails securing control housing to fram ed opening.

5.

S lide heater out. To reinstall, follow  instructions in m anual under “Installation

Instructions”.

WINTERIZING

If your w ater heater plum bing system  is equipped w ith a bypass kit, use it to close
off the w ater heater, drain the w ater heater com pletely and leave the w ater heater
close d  off (out of the system ) in the bypass position 

particularly

 if yo u are

introducing antifreeze into the plum bing system . A ntifreeze can be very corrosive
to the anode rod creating prem ature failure and heavy sedim ent in the tank. If the
plum bing system  is not equipped w ith a bypass kit, and you intend to winterize by
adding antifreeze to the system , rem ove the a node rod (storing it for the w inter)
and replace it w ith a 3/4" drain plug.

FOR YOUR SAFETY READ BEFORE LIGHTING

W A R N IN G !  If the user of this appliance fails to m aintain it in  th e c ondition in w hich is w as s hipped from  th e factory or if the appliance is not used solely
for its intended purpose or if appliance is not m aintained in accordance w ith the instruction in this m anual, then the risk of a  fire and/or the production of
carbon m onoxide exists w hich can cause personal injury, property dam age or loss of life.

OPERATING INSTRUCTIONS

W A R N IN G ! If you do not follow  these instructions exactly, a fire or
explosion m ay result causing property dam age, personal injury or loss of
life.

W A R N IN G : B efore o perating  w ater he ater, b e s ure tank  is filled w ith w ater.
S ee, “S afety W arning s”.

A

. T h is a pp lia nce  d oe s n ot h ave  a  p ilo t. It is e qu ip pe d w ith  a n ig nitio n  d e v ic e

w hich autom atically lights the burner. D o not try to light the burner by hand.

B .

B E FO R E  LIG H TIN G  sm ell all around the applian ce area for gas. B e sure to

sm ell next to the floor because som e gas is heavier than air and w ill settle on the
floor.

WHAT TO DO IF YOU SMELL GAS

C

D o not try to light any appliance.

C

D o not touch any electric sw itch.

C

D o not use any phone in your building.

C

Im m ediately  call your gas supplier from  a neighbor’s phone. Follow  the gas
supplier’s instructions.

C

If you cannot reach your gas supplier, call the fire departm ent.

C .  

This is an autom atic gas valve, no adjustm ents are necessary. D o not attem pt

to repair the gas valve. This m ay result in a fire or explosion.

D .

D o not use this appliance if any part has been under w ater. Im m ediately call

a qualified service technician to inspect the appliance and to replace any part of
the control system  and any gas control w hich has been under w ater.

E .

B efore operating w ater heater, check the location of the vent to m ake sure it

w ill not be blocked by the opening of any door on the trailer. If it can be blocked,
do not operate the w ater heater w ith the door open.

OPERATING INSTRUCTIONS

1.

S TO P ! R ead the safety inform ation provided.

2.

Turn off all electric power to the appliance.

3.

Turn “O FF ” gas supply.

4.

W ait five m inutes for gas to clear the area. If you sm ell gas then STO P ! Follow

instructions in item  B  of the safety inform ation. If you don’t sm ell ga s, go to next
step.

5.

 Turn “O N ” gas supply.

6.

Turn on electrical pow er to the appliance.

7.

Turn sw itch to "O N " position. If the burner does n o t light, the system  w ill

autom atically attem pt tw o m ore tries for ignition before lock-out. 

N O T E :

 E ach ignition cycle w ill have a 15 second purge  before spark cycle  if

system   is  a  three  try  system .

8.

If lockout occurs before m ain burner lights, turn sw itch to “O FF ”, w ait five

seconds and turn sw itch to “O N ” position. This w ill restart the ignition cycle. The
first start-u p of the heater m a y require several ignition cycles before all air is
purged from  the gas lines.

If the burner w ill not com e on, the follow ing item s should be checked before calling
a service person.

1.

S w itch turned off.

2.

G as supply to heater is em pty or turned off.

3.

R eset button on E C O  is tripped.

TO TURN OFF WATER HEATER

1. Turn sw itch to “O FF” position.

2.

Turn off electrical pow er to the appliance.

3.

Turn off gas supply.

4.

If v e h icle is to be stored or heater is going to be turned off w hile subject to

freezing tem perature, drain water heater. (S ee “D raining and Storage
Instructions.”) 

Summary of Contents for SW4D

Page 1: ...st not be supplied from occupied spaces INSTALLATION INSTRUCTIONS Minimum clearance from combustible construction on sides top floor and rear 0 inches Provide room for access to rear of heater for servicing Provide an opening flush with floor in outer wall of coach as shown Wall of coach should be framed as shown in Figure 1 Maintain inside dimensions listed below Do not install on carpet unless t...

Page 2: ...cal connections MAINTENANCE W ARNING If the user of this appliance fails to maintain it in the condition in which it was shipped from the factory or if the appliance is not used solely for its intended purpose or if appliance is not maintained in accordance with the instructions in this manual then the risk of a fire and or the production of carbon monoxide exists which can cause personal injury p...

Page 3: ...cket at the top of the water heater tank This air pocket will form in the tank by design However it will be reduced over time by the everyday use of your water heater To replenish this air pocket 1 Turn off water heater 2 Turn off cold water supply line 3 Open a faucet in the RV 4 Pull out on the handle of the Pressure Relief P T Valve and allow water to flow from the valve until it stops 5 Releas...

Page 4: ...rial numbers located on the water heater and the nature of the defect Transportation of the unit to and from the Service Center and or travel expenses of the Service Center to your location is the responsibility of the owner user A listing of authorized Service Centers is included in the owner s packet supplied with the water heater and a current listing may be obtained from Suburban If you cannot...

Reviews: