1. Set
ECHOLOGGER_DUAL
item to
true
in
[PAYLOADS]
section:
[PAYLOADS]
ECHOLOGGER_DUAL=true
2. Set the
MAX_SENSOR_ANGLE_DEG
parameter in the
[ECHOLOGGER_DUAL]
section
for data filtering by echosounder tilt while recording. Set to 90 degrees for disabling.
3. Set the
MIN_SENSOR_DEPTH_M
parameter in the
[ECHOLOGGER_DUAL]
section for
data filtering by echosounder depth value while recording. Set to zero for disabling:
[ECHOLOGGER_DUAL]
MAX_SENSOR_ANGLE_DEG=10
MIN_SENSOR_DEPTH_M=0.1
4. Set the
RANGE_HIGH_M
, the
RANGE_LOW_M
, the
DEADZONE_HIGH_MM
, and the
DEADZONE_LOW_MM
parameters in the
[ECHOLOGGER_DUAL]
section according to
the water body to be explored:
[ECHOLOGGER_DUAL]
DEADZONE_HIGH_MM=500
DEADZONE_LOW_MM=1000
RANGE_HIGH_M=10
RANGE_LOW_M=10
5. Set the
FREQUENCY_HIGH_HZ
and the
FREQUENCY_LOW_HZ
parameters in the
[ECHOLOGGER_DUAL]
section. Default values are set for D052:
[ECHOLOGGER_DUAL]
FREQUENCY_HIGH_HZ=200000
FREQUENCY_LOW_HZ=50000
6. One may choose the output data format for Echologger ECT D052/D032. The
NMEA
value is useful when only NMEA log file should be recorded. The
ECHOSOUNDER
mode
is used to record both NMEA and SEG-Y logs:
[ECHOLOGGER_DUAL]
MODE=NMEA
; or
MODE=ECHOSOUNDER
Echosounder Setup
UgCS SkyHub User Manual
Copyright © 2019—2021, SPH Engineering
68
Revision 5 • November 2021