TROUBLESHOOTING
Problem
Probable Causes
Remedy
Light Source dead – LED
indicator on desk top PSU
not illuminated
Mains supply off
Check supply and reinstate
Loose mains plug
Check plugs
PSU faulty
Replace PSU
Light Source dead – LED
indicator on desk top PSU
illuminated, but LCD
display on Light Source
not illuminated
Loose DC plug
Check plug
PSU faulty
Check PSU output – Replace PSU
Light Source Faulty
Replace Light Source
Light Source no light
output – LED, but LCD
display on Light Source is
illuminated
If programme Mode is set to “REMO”, light source may
have been switched off using RF remote control
Switch array on using RF remote control
LED array/driver faulty
Replace Light Source
RF remote controller
range reduced
Remote batteries failing
Replace batteries as per User Guide
Another RF device causing interference
Check for another RF device in same area
RF remote control needs resetting
Remove and reinsert batteries as per User Guide
RF remote failing
Replace remote
Light source receiver failing
Replace Light Source
Light source won’t
respond to RF remote
controller
Light source not in Remote mode
Check mode programming and set to “REMO”
Remote batteries failed
Replace batteries as per User Guide
RF remote control needs resetting
Remove and reinsert batteries as per User Guide
RF remote failed
Replace remote
Light source receiver failed
Replace Light Source
Not responding to DMX –
no rotating symbol on
LCD display
Light source not in “DMX”mode
Check mode programming and set to “DMX”
DMX address incorrectly set
Change address on light source or DMX controller
No DMX signal from controller
Check DMX controller for correct setting
Wiring fault on DMX cables/connections
Check cable connections and repair as necessary
DMX driver failure
Change Light Source
Not fully responding to
DMX – some but not all
colours controllable, no
rotating symbol on LCD
display
Light source address out of range – not 5 available
channels on DMX controller
Change address on light source or DMX controller to make 6
channels available
Not responding to DMX –
no light output, rotating
symbol on LCD display
Incorrect address set on light source or controller
Check addresses
No values set in DMX channel
Check DMX controller channel values
Channel 6 value high (251-255) switching off the array
Reduce channel 6 value to <251
LED array/driver failed
Change light source
Unit in Master mode but
Twinkle wheel not moving
Twinkle Motor switched off
Check “TWNK” mode setting
Internal component/motor failure
Replace Light source
Poor light output on fibre
Unit needs cleaning
Carefully clean the LED lens with a dry cloth
Clean fibre common end
Fibre port connector not plugged in correctly
Ensure plugged in correctly and secured with locking screw