InSTALLATIOn
3�15�2 Position and dimensions
1�
Air intake
2�
Air delivery
2
1
i10 VSD SMART
i16 VSD SMART
Diameter of fittings
100 mm
120 mm
3�15�3 Air outlet orientation
A
Default position
B
Rotation
1�
Fan
1
1
A
B
3�15�4 Connection to the system
Preliminary warnings
Before connecting the piping, make sure that it do not
contain stones, sand, rust or foreign matter that could
damage the plant.
The connection piping must be suitably supported so
as not to bear on the appliance with its weight.
The air ducts must be insulated and well stretched to
allow good air flow.
Avoid partial insulation of the pipes.
Avoid installing the unit near heat sources.
The system needs a correct air flow in order to work effi
-
ciently. It Is therefore important to get the correct distri-
bution without bottlenecks , by maintaining the original
nozzle diameter and not exceeding the recommended
length of pipes.