background image

  

  

H

P 07 Operating Manual

17

UES AG · Roemerstraße 15 · D-47809 Krefeld

Tel.: +49 (0)2151-72950 · Fax: +49 (0)2151-7295578 · [email protected] · www.ues-int.net

Technical Data

Modular system for three types of manual hot melt application:

• 

Spot/bead 

- H300 P

• 

Needle seat 

- H300 P-NA

• 

Spraying application - H300 P-SP

The basis body of the gun is the same for all three types. The desired type of handgun is constructed by 

exchanging the module and adding extern components. 

The storage takes place in construction groups so that the assembly can take place in short time.

Weight

1.15kg with cord set without hose

Measurement  

220 x 210 x 38 mm

Voltage

230V AC, 50Hz

Power

150W

Start time

15 min to set temperature

Degree of protection  IP22
Housing

PA6.6GFK30 heat resistant and isolating

Temperature

200 °C long run, 230 °C short term

Work pressure

40 – 50 bar, short term max. 75 bar

Flowing through

without nozzle 0.451/min at 1000mPas

Needle stroke

depending on the module 2.4 mm max. linear opening at the entire stroke

Heating

transmission of the heat at the entire length of the glue block, 2 sensor positions 

for differentiated heating characteristics

Sensor

Ni120 or Pt100, FeKo, NTC Dm4-0.05x15 mm cord set length 500 mm  

compatible to  UES, Nordson

®

, Meltex

®

, Robatech

®

The standard installation of each handgun includes the electrical release and opening and closing appli-

ance.

Exchange of the module should only take place when the trigger is pulled to the end.

The adjustment of the release depends on the pressure. 0,5mm clearance between housing and trigger 

(see drawing 6.3). In this position the switch must not yet be switched.

Through connectors the cord set can be exchanged, e.g. connection of the UES hose for AD31.

The length of the standard needle seat is 40 mm- reaching from glue block to nozzle tip.

The STOP position of the safety lever avoids an unintentional release of the trigger.

Spraying application

For spraying application you need additionally compressed air at your handgun.

• 

e.g.  usage  hose  with  intregrated  spray  air  tube  (e.g.  2,4m  hose;  UES  part  no.  100292)                                                       

• 

handy appurtenance: Spray air control HP 07 – not operated grip shift switched off the air for the gun  

(inline micro switch) (UES article: 100493)

Summary of Contents for HP 07

Page 1: ...HP 07 Hand Gun Operating Manual HP 07 PR...

Page 2: ......

Page 3: ...ons relating to the production machine 5 Safety symbols 6 Technical description 7 Introduction 7 Putting into operation 8 Check 8 Hydraulic connections 8 Release stop 9 Start off the system 9 Handling...

Page 4: ...compact construction and the possibility of modular extension guarantees a variable use at multi purpose applications Information about the equipment and options is given in the paragraphs 6 1 and 6...

Page 5: ...nous gases which have to be filtered Under no circumstances is the glue application unit to be operated under the following conditions Near escaping substance or exploding gases or materials Without t...

Page 6: ...parts have a high operating temperature Caution high voltage This type of work is only to be carried out by qualified personal Caution hand injury Risk of entrapment if incautiously operated Caution...

Page 7: ...ge and a temperature sensor Ni 120 PT100 NTC etc regulate the temperature of the handgun independent of the hose and the tank temperature When tank hose and handgun reach the temperatures which were a...

Page 8: ...tions Screw the hose using a spanner SW 19 onto the turning nipple To avoid the turning of the turning nipple hold it with a spanner SW 19 Before fastening the hose remount the hose clamp and tighten...

Page 9: ...avoid an uncontrolled leak of hot melt adhesive After reaching the adjusted temperatures please tighten once more all hydraulic screw connections and fix the enclosed contact protection at the hydraul...

Page 10: ...Nadelsitz needle seat offers the following advantages Needle seat with integrated nozzle 0 20 mm 1 5 mm Special hardened needle seat Strong reducing of nozzle obstructions Angle hair is reduced to min...

Page 11: ...and screw off the clamping screw counter clockwise After having removed the clamping screw out of the service block the trigger can be put back to normal position Hereby the module is pushed about 4mm...

Page 12: ...e in order to avoid an uncontrolled leakage of hot melt adhesive Please turn the stroke adjusting screw using a 4mm hexagon socket screw key clockwise trigger moves backwards up to a difference of 0 5...

Page 13: ...ne Nozzle obstructed Replace or clean nozzle Nozzle too big Install smaller nozzle Bead too thick or glue splashes from the substratum Too high pump pressure Reduce pump pressure Adhesive is too hot R...

Page 14: ...system Disconnect the electrical connection of hose and HP07 Disconnect the hydraulic connection of hose and HP07 Loosen all hexagon socket screws and remove HP07 housing Disconnect electric and cord...

Page 15: ...icro switch optional for spraying application Pos 14 Temperature sensor Pos 15 Heater cartridge Pos 16 Earthing cable Loosen the earthing screw M3X6 using a 2 5 mm hexagon socket screw key Pos 16 Pull...

Page 16: ...list Pos Description Art No 1 Service block 2 Housing L R 3 Trigger 4 Stroke adjusting screw 5 Safety lever 6 Electronic plug 7 Module H300P 000174 Module H300PNA 0 50 mm 000181 Module H300PSP 000180...

Page 17: ...eating transmission of the heat at the entire length of the glue block 2 sensor positions for differentiated heating characteristics Sensor Ni120 or Pt100 FeKo NTC Dm4 0 05x15 mm cord set length 500 m...

Page 18: ...lf ltigung und Weitergabe an Dritte ist strengstens untersagt 00017711 Schaltplan E Installation P UES 01 12 1998 1 von 1 kein 0 0 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 000188 HLP 230V 200W PTFE Litze t 000...

Page 19: ...ht Verfielf ltigung und Weitergabe an Dritte ist strengstens untersagt 00017712 Schaltplan E Installation P 3000 01 12 1998 1 von 1 kein 0 0 1 2 3 4 5 6 1 2 3 4 5 6 7 8 000188 HLP 230V 200W PTFE Litze...

Page 20: ...lf ltigung und Weitergabe an Dritte ist strengstens untersagt 00017713 Schaltplan E Installation P Meltex 01 12 1998 1 von 1 kein 0 0 1 2 3 4 5 6 1 2 3 4 5 6 7 8 000188 HLP 230V 200W PTFE Litze t Pt10...

Page 21: ...rsion Konst Datum Zeichnung unterliegt dem Urheberrecht Verfielf ltigung und Weitergabe an Dritte ist strengstens untersagt 00017714 Schaltplan E Installation P Robatech NTC 01 12 1998 1 von 1 kein 0...

Page 22: ...22 HP 07 Operating Manual UES AG Roemerstra e 15 D 47809 Krefeld Tel 49 0 2151 72950 Fax 49 0 2151 7295578 info ues int net www ues int net Rev 1 0 Stand 03 2012...

Reviews: