background image

  

  

H

P 07 Operating Manual

5

UES AG · Roemerstraße 15 · D-47809 Krefeld

Tel.: +49 (0)2151-72950 · Fax: +49 (0)2151-7295578 · [email protected] · www.ues-int.net

Qualified personnel can only carry out installation and maintenance work,

meaning only the personnel that has been trained on such appliances and who has the required experi-

ence and qualification with these or similar appliances and who is experienced in the safety and accident 

prevention procedures and thus can recognise these immediately. 

Any work, repairs or maintenance made on the gluing pattern system is only to be carried out when the 

appliance has been disconnected from the main power supply and the compressed air has been cut off 

(depressurise the system).

The appliance may not be operated without the relevant casing and safety protection. Beware of exposed 

moving and rotating appliance parts such as motor and pump movement and also rising/sinking parts.

Attention! Do not use this appliance for anything other than that, for which it was manufactured!

Many exposed parts of this unit, such as the hot glue hose and order valve operate at a very high tempe-

rature, which can result, when coming into contact with hot and pressurised glue, in severe burns to the 

skin. Therefore when operating this unit, filling the melting tanks, installation and construction of a hose 

and order valves, protective clothing (safety gloves and glasses as well as clothing and shoes) are to be 

worn at all time. Several glues produce poisonous gases, which have to be filtered. 

Under no circumstances is the glue application unit to be operated under the following conditions:

 

- Near escaping substance or exploding gases or materials

 

- Without the appropriate safety appliances

 

- Temperatures lower than 5° C and more than 45°

Safety precautions regarding the glue

The utmost care is required when working with hotmelt glues! Material of this kind has a high and quick 

bonding quality, so that it can even still be very hot when it is hardened and can lead to burns when coming 

into to contact with exposed skin.

The safety procedures of the glue manufactures are to be followed. They can be found in the relevant in-

formation sheet of the respective glue.

Always abide to the operational gluing temperatures suggested by the manufactures!

During work with hotmelt glues wear protective gloves, glasses and long sleeved clothes to reduce the risk 

of burns. In the event of an accident happening with hot glue, do not try and remove the glue from the skin 

but run the burnt area under cold water until the glue has cooled off and then contact a doctor immediately.

Safety precautions relating to the production machine

The recommended safety procedures when dealing with production- and or packing machines are to be 

taken from the manual delivered with these machines.

When installing, operating and maintaining the unit the safety measures referring to the main machine which 

the unit is built into must be taken into consideration.

Attention: Before installation- and adjustment work is carried out,  

the appliance must be disconnected from the mains!

Safety instructions

The following safety instructions must be adhered to!

Summary of Contents for HP 07

Page 1: ...HP 07 Hand Gun Operating Manual HP 07 PR...

Page 2: ......

Page 3: ...ons relating to the production machine 5 Safety symbols 6 Technical description 7 Introduction 7 Putting into operation 8 Check 8 Hydraulic connections 8 Release stop 9 Start off the system 9 Handling...

Page 4: ...compact construction and the possibility of modular extension guarantees a variable use at multi purpose applications Information about the equipment and options is given in the paragraphs 6 1 and 6...

Page 5: ...nous gases which have to be filtered Under no circumstances is the glue application unit to be operated under the following conditions Near escaping substance or exploding gases or materials Without t...

Page 6: ...parts have a high operating temperature Caution high voltage This type of work is only to be carried out by qualified personal Caution hand injury Risk of entrapment if incautiously operated Caution...

Page 7: ...ge and a temperature sensor Ni 120 PT100 NTC etc regulate the temperature of the handgun independent of the hose and the tank temperature When tank hose and handgun reach the temperatures which were a...

Page 8: ...tions Screw the hose using a spanner SW 19 onto the turning nipple To avoid the turning of the turning nipple hold it with a spanner SW 19 Before fastening the hose remount the hose clamp and tighten...

Page 9: ...avoid an uncontrolled leak of hot melt adhesive After reaching the adjusted temperatures please tighten once more all hydraulic screw connections and fix the enclosed contact protection at the hydraul...

Page 10: ...Nadelsitz needle seat offers the following advantages Needle seat with integrated nozzle 0 20 mm 1 5 mm Special hardened needle seat Strong reducing of nozzle obstructions Angle hair is reduced to min...

Page 11: ...and screw off the clamping screw counter clockwise After having removed the clamping screw out of the service block the trigger can be put back to normal position Hereby the module is pushed about 4mm...

Page 12: ...e in order to avoid an uncontrolled leakage of hot melt adhesive Please turn the stroke adjusting screw using a 4mm hexagon socket screw key clockwise trigger moves backwards up to a difference of 0 5...

Page 13: ...ne Nozzle obstructed Replace or clean nozzle Nozzle too big Install smaller nozzle Bead too thick or glue splashes from the substratum Too high pump pressure Reduce pump pressure Adhesive is too hot R...

Page 14: ...system Disconnect the electrical connection of hose and HP07 Disconnect the hydraulic connection of hose and HP07 Loosen all hexagon socket screws and remove HP07 housing Disconnect electric and cord...

Page 15: ...icro switch optional for spraying application Pos 14 Temperature sensor Pos 15 Heater cartridge Pos 16 Earthing cable Loosen the earthing screw M3X6 using a 2 5 mm hexagon socket screw key Pos 16 Pull...

Page 16: ...list Pos Description Art No 1 Service block 2 Housing L R 3 Trigger 4 Stroke adjusting screw 5 Safety lever 6 Electronic plug 7 Module H300P 000174 Module H300PNA 0 50 mm 000181 Module H300PSP 000180...

Page 17: ...eating transmission of the heat at the entire length of the glue block 2 sensor positions for differentiated heating characteristics Sensor Ni120 or Pt100 FeKo NTC Dm4 0 05x15 mm cord set length 500 m...

Page 18: ...lf ltigung und Weitergabe an Dritte ist strengstens untersagt 00017711 Schaltplan E Installation P UES 01 12 1998 1 von 1 kein 0 0 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 000188 HLP 230V 200W PTFE Litze t 000...

Page 19: ...ht Verfielf ltigung und Weitergabe an Dritte ist strengstens untersagt 00017712 Schaltplan E Installation P 3000 01 12 1998 1 von 1 kein 0 0 1 2 3 4 5 6 1 2 3 4 5 6 7 8 000188 HLP 230V 200W PTFE Litze...

Page 20: ...lf ltigung und Weitergabe an Dritte ist strengstens untersagt 00017713 Schaltplan E Installation P Meltex 01 12 1998 1 von 1 kein 0 0 1 2 3 4 5 6 1 2 3 4 5 6 7 8 000188 HLP 230V 200W PTFE Litze t Pt10...

Page 21: ...rsion Konst Datum Zeichnung unterliegt dem Urheberrecht Verfielf ltigung und Weitergabe an Dritte ist strengstens untersagt 00017714 Schaltplan E Installation P Robatech NTC 01 12 1998 1 von 1 kein 0...

Page 22: ...22 HP 07 Operating Manual UES AG Roemerstra e 15 D 47809 Krefeld Tel 49 0 2151 72950 Fax 49 0 2151 7295578 info ues int net www ues int net Rev 1 0 Stand 03 2012...

Reviews: