IMPORTANT SAFETY WARNINGS

 

 

WARNING

Read entire Safety Notes section regarding potential hazard and proper instructions before using this meter. In this manual 

the word “

WARNING

” is used to indicate conditions or actions that may pose physical hazards to the user. The word 

CAUTION

” is used to indicate conditions or actions that may damage this instrument. 

 

 

WARNING

To ensure safe operation and service of the tester, follow these instructions. Failure to observe these warnings can result in 

severe injury or death.

 

 

WARNING

•   Before each use, verify meter operation by measuring a known voltage.
•   Never use the meter on a circuit with voltages that exceed the category based rating of this meter. 
•   Do not use this meter during electrical storms or in wet weather.
•   Do not use the meter or test leads if they appear damaged. 
•   Ensure meter leads are fully seated and keep fingers away from the metal probe contact when making measurements.    

  Always grip the leads behind the finger guards molded into the probe.
•   Do not open the meter to replace batteries while the probes are connected. 
•   To avoid false readings that can lead to electrical shock, replace batteries if a low battery indicator appears.  
•   Unless measuring voltage, shut off and lockout power before measuring resistance.
•   Always adhere to national and local safety codes. Use proper personal protective equipment (PPE) to prevent shock and   

  arc blast injury where hazardous live conductors are exposed.
•   Always turn off power to a circuit or assembly under test before cutting, unsoldering or breaking the current path. Even    

  small amounts of current can be dangerous.
•   Always disconnect the live test lead before disconnecting the common test lead from the circuit.  
•   In the event of electrical shock, ALWAYS bring the victim to the emergency room for evaluation, regardless of victim’s    

  apparent recovery. Electrical shock can cause unstable heart rhythms that may need medical attention.

•   If any of the following occur during testing, turn off the power source to the circuit being tested: arching, flame, smoke,    

  extreme heat, smell of burning materials or discoloration or melting of components. 

 

 

WARNING

Higher voltages require greater awareness of physical safety hazards. Before connecting the test leads; turn off power to 

the circuit under test, set meter to the desired function and range; connect the test leads to the meter first, then connect to 

the circuit under test. Reapply power. If an erroneous reading is observed, disconnect power immediately and recheck all 

settings and connections. 

 

 

WARNING

This meter is designed for trade professionals who are familiar with the hazards of their trade. Observe all recommended 

safety procedures that include proper lockout utilization and use of personal protective equipment that includes safety 

glasses, gloves and flame resistant clothing.

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Summary of Contents for IRT807

Page 1: ...STER Apo MIN MAX LOCK Hz Test Voltage F C SELECT TEST RANGE PI DAR A HOLD 0 0 1M 1M 10 M 100 M 1 G 2 G VDC M INSTRUCTION MANUAL ENGLISH IRT807 1000V AC DC Digital Insulation Resistance Tester www Glob...

Page 2: ...328 to 2462 F 200 to 1350 C 11 Resistance 12 Continuity 12 Diode Test 13 Capacitance 13 mAmps AC DC 14 Frequency 14 Earth bond Resistance 15 Insulation Resistance 1000V 500V 250V 100V 50V 16 Measuring...

Page 3: ...emperature 14 to 122 F 10 to 50 C Operating Humidity 75 Operating Altitude 6 526 ft 2000m Pollution Degree 2 Over range OFL is displayed Backlight Yes Refresh Rate 3 sec Dimensions 8 27 x 3 52 x 2 17...

Page 4: ...ment PPE to prevent shock and arc blast injury where hazardous live conductors are exposed Always turn off power to a circuit or assembly under test before cutting unsoldering or breaking the current...

Page 5: ...e test Continuity SMOOTH INSULATION 50V 1000V Insulation Test mV DCmV PI DAR Polarization Index Dielectric Absorption Ratios mA Milliamp AC DC Auto HOLD ZERO ZERO Greater Than HOLD Auto power off acti...

Page 6: ...gory Max Indicator Maximum CAT Rating for input jacks Use CATIII test leads or higher Zero Test Lead Port Fused used for Zero Ohms and mA Common Test Lead Port Volt Insulation Test Lead Port CATIV 600...

Page 7: ...er under protective rubber boot Q Serial Number under kick stand Default Press x1 k Voltage 1000V AC IRT807 OFF ZERO kHz Temp SMOOTH mV mA INSULATION V V 50V 1000V INSULATION TESTER MIN MAX LOCK Hz Te...

Page 8: ...y generated by frequency motor drives and inverters WARNING Use CATIII rated Test leads or higher Do not attempt to measure more than 1000V AC Keep hands below finger guards when measuring high voltag...

Page 9: ...es MIN MAX Test Voltage F C RANGE LOCK A HOLD SELECT DC MILLIVOLTS RANGE RESOLUTION ACCURACY 400mV DC 0 1mV 0 2 3 dgts Temperature 328 to 2462 F 200 to 1350 C Fahrenheit is the default temperature mea...

Page 10: ...PI DAR A HOLD 0 0 1M 1M 10 M 100 M 1 G 2 G VDC M IRT807 Apo Default Press x1 Press x2 Press x3 SELECT IRT807 OFF ZERO kHz Temp SMOOTH mV mA INSULATION V V 50V 1000V INSULATION TESTER Apo MIN MAX LOCK...

Page 11: ...C RANGE CAPACITANCE RANGE RESOLUTION ACCURACY OVERLOAD PROTECTION 10 00nF 0 01nF 2 5 5 dgts 600V 100 0nF 0 1nF 1 000 F 0 001 F 10 00 F 0 01 F 100 00 F 0 1 F 1000 F 1 F 3 5 dgts 10000 F 1 F WARNING Ca...

Page 12: ...AC 45Hz to 1000Hz 40mA 0 01mA 1 5 5 dgts 1 400mA 0 1mA DC 40mA 0 01mA 0 5 5 dgts 400mA 0 1mA 1 1kHz bandwidth Overload Protection 440mA 1000V FAST fuse IRT807 OFF ZERO kHz Temp SMOOTH mV mA INSULATION...

Page 13: ...ect if the circuit is energized 5 The dashes will display until the TEST Button is pressed and a valid resistance value is detected 6 The High Voltage symbol will display if greater than 2V AC DC is p...

Page 14: ...ust be connected in parallel to the circuit or circuit element under test Set Rotary dial to INSULATION and press RANGE button to select desired voltage The display will show until the button is press...

Page 15: ...unction dial to INSULATION position and press RANGE button to select desired voltage Press the PI DAR button to select PI or DAR The display shows until TEST button is pressed and a valid resistance i...

Page 16: ...A 1000V 1R 10kA Replace the battery cover Replace the protective rubber boot Fuse AA battery AA battery AA battery AA battery Fuse AA battery AA battery AA battery AA battery Removed protective rubber...

Page 17: ...ive from such defects the unit will be repaired or replaced at UEi s option This warranty covers normal use and does not cover damage which occurs in shipment or failure which results from alteration...

Reviews: