RECOMMENDED PRACTICES AND WARNINGS 

United Electric Controls Company recommends careful consideration 
of the following factors when specifying and installing UE pressure and temperature 
units. Before installing a unit, the Installation and Maintenance instructions provided 
with unit must be read and understood. 

•  To avoid damaging unit, proof pressure and maximum temperature limits stated in 

literature and on nameplates must never be exceeded, even by surges in the system. 
Operation of the unit up to maximum pressure or temperature is acceptable on a lim-
ited basis (e.g., start-up, testing) but continuous operation must be restricted to the 
designated adjustable range. Excessive cycling at maximum pressure or temperature 
limits could reduce sensor life.

•  A back-up unit is necessary for applications where damage to a primary unit could 

endanger life, limb or property. A high or low limit switch is necessary for applica-
tions where a dangerous runaway condition could result.

•  The adjustable range must be selected so that incorrect, inadvertent or malicious 

setting at any range point cannot result in an unsafe system condition.  

•  Install unit where shock, vibration and ambient temperature fluctuations will not 

damage unit or affect operation. When applicable, orient unit so that moisture does 
not enter the enclosure via the electrical connection. When appropriate, this entry 
point should be sealed to prevent moisture entry.

•  Unit must not be altered or modified after shipment. Consult UE if modification is 

necessary.  

•  Monitor operation to observe warning signs of possible damage to unit, such as 

drift in set point or faulty display.  Check unit immediately.

•  Preventative maintenance and periodic testing is necessary for critical applications 

where damage could endanger property or personnel.

•  Electrical  ratings  stated  in  literature  and  on  nameplate  must  not  be  exceeded. 

Overload on a switch can cause damage, even on the first cycle.  Wire unit accord-
ing to local and national electrical codes, using wire size recommended in installa-
tion sheet.

•  Do not mount unit in ambient temp. exceeding published limits.

LIMITED WARRANTY

Seller warrants  that  the  product  hereby purchased  is,  upon  delivery,  free from  defects 
in  material  and  workmanship  and  that  any  such  product  which  is  found  to  be  defec-
tive in such workmanship or material will be repaired or replaced by Seller (Ex-works, 
Factory, Watertown, Massachusetts. INCOTERMS); provided, however, that this warranty 
applies only to equipment found to be so defective within a period of 24 months from 
the  date  of  manufacture  by  the  Seller  (36  months  for  the  Spectra  12  and  One  Series 
products;  18  months  for  Temperature  Sensors).  Seller  shall  not  be  obligated  under 
this  warranty  for  alleged  defects  which  examination  discloses  are  due  to  tampering, 
misuse,  neglect,  improper  storage,  and  in  any  case  where  products  are  disassembled 
by  anyone  other  than  authorized  Seller’s  representatives.  EXCEPT  FOR  THE  LIMITED 
WARRANTY  OF  REPAIR  AND  REPLACEMENT  STATED  ABOVE,  SELLER  DISCLAIMS 
ALL  WARRANTIES  WHATSOEVER  WITH  RESPECT  TO  THE  PRODUCT,  INCLUDING  ALL 
IMPLIED  WARRANTIES  OF  MERCHANTABILITY  OR  FITNESS  FOR  ANY  PARTICULAR 
PURPOSE. 

LIMITATION OF SELLER’S LIABILITY

Seller’s liability to Buyer for any loss or claim, including liability incurred in connection 
with (i) breach of any warranty whatsoever, expressed or implied, (ii) a breach of contract, 
(iii) a negligent act or acts (or negligent failure to act) committed by Seller, or (iv) an act 
for which strict liability will be inputted to seller, is limited to the “limited warranty” of 
repair and/or replacement as so stated in our warranty of product.  In no event shall the 
Seller be liable for any special, indirect, consequential or other damages of a like general 
nature, including, without limitation, loss of profits or production, or loss or expenses of 
any nature incurred by the buyer or any third party.
UE specifications subject to change without notice.

CP08113000

ECN #: 6476

Summary of Contents for Field Safety System One Series

Page 1: ...HAZARDOUS AND THE FOLLOWING HAZARDOUS LOCATIONS AND IS ATEX AND IECEX CERTIFIED SUITABLE FOR APPROPRIATE USE IN GAS AND DUST ZONE 1 APPLICATIONS Model 2SLP N America Europe International Flameproof Ce...

Page 2: ...eries transmitter switch product line is based on an all solid state electronic module that incorporates a microprocessor The One Series Field Safety System is a loop powered all in one device connect...

Page 3: ...y pushing the right g button once the display will scroll as follows SP1 XX XX DB1 XX XX SP2 XX XX DB2 XX XX By pushing the left 2 button once the display will scroll the min max process values record...

Page 4: ...re that the sensor housing will not be damaged and where the measured temperature is representative of the surrounding environment For Local Spring Loaded model T A suitable thermowell made from corro...

Page 5: ...ved Tools Required Small flat head screwdriver wire strippers TO PREVENT IGNITION DISCONNECT POWER BEFORE REMOVING ENCLOSURE COVER KEEP COVER TIGHT WHILE IN OPERATION DO NOT DISCONNECT EQUIPMENT UNLES...

Page 6: ...diagnostics to determine the integrity of the SRO wiring and if the SRO is functioning properly NOTE As an alternative to loop power model 2SLP may be wired directly to a 24 VDC power supply and minus...

Page 7: ...t function as normal NOTE The 4 20 mA analog signal is not possible in this wiring configuration In this configuration the 4 20 mA output and IAW Output are monitored by the safety system logic solver...

Page 8: ...Field Safety System fully configured where the health status IAW and SRO switch status signals are being monitored by a logic solver PLC or DCS These connections are not required however UE recommend...

Page 9: ...00 0 39 714 3 1045 5 40 761 9 1090 9 No Fault Displayed 4 20 mA Normal Operating range Unused Fault 3 6 3 8 mA Normal Under range 4 20 20 5 mA Normal Over range 21 0 mA 21 0 mA only when the temperatu...

Page 10: ...t 2 button increments the blinking digit The right g button sets the digit and moves to the next Once a valid password is entered OK will appear on the display Press and release the right g button CLR...

Page 11: ...opens on falling process values that reach the set point OPEN WINDOW The Safety Relay Output opens when process values are within a specified range set by two points set point high and set point low P...

Page 12: ...6 Resetting the Maximum Minimum Values The One Series Field Safety System continuously records the readings from the sensor and stores the minimum and maximum MAX MIN peak hold values in non volatile...

Page 13: ...and change the offset Zero is the factory setting Press the left 2 button to increment the blink ing digit Press the right g button to enter and move to the next digit Press the right g button to ente...

Page 14: ...ity to detect that the process port may be plugged It does this by monitoring the sensor for changes over time The amount of change and the time period are programmable If the process variable does no...

Page 15: ...ations it is desirable to dampen the Safety Relay Output response and prevent intermittent false trips due to pressure spikes or other transient isolated events The Filter feature provides a software...

Page 16: ...left 2 button to change to NEG Press the right g button to view and change the scale Press the left 2 button to increment the blinking digit Press the right g button to enter and move to the next digi...

Page 17: ...en check all sensor connections E 16 Diagnostic Fault Sensor SHORT A short circuit has been detected on the sensor drive pins 2 3 Diagnostic Fault Sensor Short check all sensor connections E 18 Diagno...

Page 18: ...ORIGINAL DATE DRWN CHKD APPD DO NOT SCALE THIS DRAWING DOC DE733010102 Rev B EM ONE SERIES 1X NAMEPLATE A 6211 847 SR 5 14 15 6211 847 DESCRIPTION DATE DRWN APPD UNLESS OTHERWISE SPECIFIED DIMENSIONS...

Page 19: ...end on sensor range Invalid PWORD BOTH Abort NO RESET OK Flash Err Abort BDOOR PWORD Valid SAVING SAVING One Series Field Safety System LCH1 ON OFF OFST POS NEG 8888 Set Blinking Digit Increments Blin...

Page 20: ...R PORT 1 2 14 NPT SENSOR PORT 1 20 NPT SENSOR PORT 1 20 NPT SENSOR PORT 111 92 mm 76 2 mm 133 35 mm 12 7 mm SURFACE MOUNTING KIT 6361 704 144 78 mm 134 62 mm 137 16 mm 154 94 mm 134 62 mm 137 16 mm 26...

Page 21: ...LATED CABLE 0 125 3 18 mm FOR DC UNITS 0 250 6 35 mm 1 2 NPT COMPRESSION FITTING 300 SERIES st st 26 AWG STRANDED TEFLON INSULATION 4 50 114 3 mm FIXED DIM EPOXY SEAL 2 00 50 8 mm FIXED DIM 1 2 14 NPT...

Page 22: ...e de fil lectrique Ne pas monter l unit des temp ratures ambiantes d passant les limites publi es Cela est particuli rement important pour les unit s de tem p rature montage locale L utilisation enve...

Page 23: ...avant de retirer le couvercle du bo tier Maintenir le couvercle ferm pendant le fonctionnement Ne pas d con necter l quipement que lorsque l alimentation est coup e ou que la zone est connue pour tre...

Page 24: ...r personnel Electrical ratings stated in literature and on nameplate must not be exceeded Overload on a switch can cause damage even on the first cycle Wire unit accord ing to local and national elect...

Reviews: